ACREL ADL SERIES DIN RAIL ENERGY METER
Quantity : 10000piece Price : 5-500USD/piece
Acrel ADL series products adopt DIN35mm guide rail installation structure, compact size, can measure electric energy and other electrical parameters, clock, rate time and other parameters can be set, high precision, good reliability, performance indicators in line with CE, UL certification of the technical requirements of the energy meter, and has the power pulse output function; RS485 communication interface can be used to realize data exchange with the host computer.
ADL Series Din Rail Energy Meter For Sale
Acrel din rail mounted energy meter is suitable for government agencies and large public buildings to measure electric energy by item, and can also be used for enterprises and institutions for electric energy management.
ADL3000-E Three Phase Multifunction Energy Meter
ADL400 Three Phase Din Rail Energy Meter
ADL200 Single Phase Din Rail Energy Meter
ADL100-ET Single Phase Din Rail Energy Meter with CT
ADL10-E Single Phase Din Rail Energy Meter
ADL Series Din Rail Energy Meter Datasheet
Type |
ADL10-E |
ADL100-ET |
ADL200 |
|
Voltage |
Reference voltage |
AC 220V |
AC 220V |
AC 220V |
Reference frequency |
45-65 Hz |
50Hz |
50Hz |
|
Consumption |
<10VA( Single phase)</span> |
<10VA</span> |
<10VA</span> |
|
Current |
Maximum current |
60A |
60A,100A |
80A |
Starting current |
0.004 Ib |
4‰Ib |
0.01A |
|
Consumption |
<4VA(Maximum current)</span> |
<4VA</span> |
<1VA</span> |
|
Measurement performance |
Accuracy |
Class 1 |
kWh Class 1 |
kWh Class 0.5 |
Standards compliant |
IEC 62053-21: 2003 |
IEC 62053-21: 2003 |
IEC 62053-21: 2003 |
|
Pluse |
Pluse width |
80+20 ms |
80±20ms |
80±20ms |
Pluse constant |
3200 imp/kWH |
1600imp/kWh |
1000imp/kWh,10000imp/kWh |
|
Communication |
Interface |
RS485 |
RS485(A+、B-) |
RS485 |
Protocol |
Modbus-RTU |
Modbus-RTU |
Modbus-RTU |
|
Outling |
L*W*H(mm) |
18*88*70 |
88*36*70 |
90*36*65 |
Temperature range |
Work |
-25℃-55℃ |
-25℃~55℃ |
-25℃-55℃ |
Storage |
-40℃-70℃ |
-40℃~70℃ |
-40℃-70℃ |
|
Humidity |
≤95%(No condensation) |
≦95% (No condensation) |
≦95% (No condensation) |
≦95% (No condensation) |
Altitude |
<2000m</span> |
<2000m</span> |
<2000m</span> |
<2000m</span> |
Type |
ADL400 |
ADL3000 |
|
Voltage |
Reference voltage |
3*57.7/100V, 3*220/380V, 3*100V, 3*380V |
3*57.7/100V,3*220/380V,3*100V,3*380V |
Reference frequency |
45-65 Hz |
50Hz |
|
Consumption |
<10VA( Single phase)</span> |
<10VA(Single phase)</span> |
|
Current |
Maximum current |
6A,80A |
6A,80A |
Starting current |
Direct connect: 0.004 Ib;Connect via: 0.001 In |
Direct connect: 0.004lb;Connect via: 0.001ln |
|
Consumption |
<4VA(Single phase rated current)</span> |
<1VA(Single phase rated current)</span> |
|
Measurement performance |
Accuracy |
Class 0.5S |
Class 0.5 |
Standards compliant |
IEC 62053-21: 2003 |
IEC 62053-22: 2003 |
|
Pluse |
Pluse width |
80+20 ms |
80+20 ms |
Pluse constant |
400imp/kWH,6400imp/kWH |
400imp/kWH,6400imp/kWH |
|
Communication |
Interface |
RS485 |
RS485 |
Protocol |
Modbus-RTU |
Modbus-RTU |
|
Outling |
L*W*H(mm) |
72*88*70 |
126.5*88*69.5 |
Temperature range |
Work |
-25℃-55℃ |
-25℃~55℃ |
Storage |
-40℃-70℃ |
-40℃~70℃ |
|
Humidity |
≤95%(No condensation) |
≦95% (No condensation) |
≦95% (No condensation) |
Altitude |
<2000m</span> |
<2000m</span> |
<2000m</span> |
Working principle Of Din Rail Energy Meter
ADL Series 3 phase kwh meter din rail use electronic circuits/chips to measure electrical energy; With partial pressure resistance or voltage signal into voltage transformer can be used for electronic measurement of small signal and current signal in the shunt or current transformer can be used for electronic measurement of small signal, using special power measurement chip will transform a good voltage and current signals are analog or digital multiplication, and electricity were accumulated, and then output frequency is proportional to the power of the pulse signal, Digital display after microcomputer processing.
ADL Series Din Rail Wireless Energy Meter FAQs
How To Calculate Maximum Demand In Energy Meter?
We will write the maximum demand function into the program of the energy meter, just need to click the button to turn the page to view the maximum demand.
How Energy Meter Calculate Power Factor?
Our energy meter has the function of measuring the power factor, and the corresponding power factor can be directly viewed on the display interface.
How Energy Meter Works?
When the energy meter is connected to the circuit under test, it will sample the voltage, current and other signals on the line to the chip, and then send to MCU through pulse, and then complete the calculation and display of various power parameters.
Now the price of 3 phase power meter modbus is reasonable, anything you need, please contact us.
Contact : Tim MA, 86 510 86179966
Good deal: buying from seller
We invite you to read our terms of use. You can also visit our FAQ section and see our information section on the risks associated with counterfeiting.
This page is about importers and exporters of ACREL ADL SERIES DIN RAIL ENERGY METER Search in a category : Electronics / Computers Search in a category : rail, acrel, energy, meter, series |
Sunday, July 08, 2012
Quantity : 1 - Price : negotiated
Mobile diving complex executed in double 20 ft marine containers with 60 m diver depth and diving station for operation of 2 working and 1 standing by divers. 1st container Diving complex: 20' marine container with additional door, illuminators and heat insulation, main switchboard...
MSCO
- 183038 - Murmansk
- +78 1 52 48 10 21
- +79 2 16 66 33 86
Thursday, April 18, 2024
Established in 1979. Hsing Wei has built itself in good quality and excellent performance printing crafts and also been related with good after-sales service to serve flexible packaging industry. For satisfying plastic film printing machine, plastic material printing machine quality...
Hsing Wei Machine Industry Co., Ltd
- hsingwei
- 408 - Taichung
- 886 4 2358 0087
Saturday, July 19, 2014
Cool White LED with color temperature 7000K to 7500K implies a mild blue tint in the white glow. Cool White is preferred in many applications because the light they output makes items illuminated appear crisper. Cool White is often preferred in bathrooms and other task areas. Note...
Real Green lighting Company
- Bonny Chan
- 529000 - Jiangmen City
- +15 6 02 20 39 93