SILICA - 905 ads
Tuesday, September 10, 2019
According to the separation mechanism of substances, Chromatography can be divided into adsorption chromatography, distribution chromatography, ion exchange chromatography and the like. The operation mode of the adsorption thin layer chromatography refers to that the adsorption capacity...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Tuesday, September 03, 2019
Chemical properties of the chromatographic column could affect the performance of the C18 HPLC column. Performance factors of C18 HPLC columns: bonding type Single tooth bonding can improve the mass transfer rate and accelerate column balance. Double tooth bonding can increase the...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Tuesday, September 03, 2019
The basic principle of SPE cartridges is that the liquid sample is made to pass through the adsorbent to retain the tested substance, and then the impurities are washed away with appropriate strength solvent, and then the tested substance is eluted with a small amount of good solvent...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Tuesday, August 27, 2019
Dalian Fuchang Chemical Co., Ltd.Its a company that is engaged in scientific research, manufacturing and trade. In 2012. Currently, we have become one of the largest comprehensive chemical company in Northeast China and own two high-grade quartz mines so as to lay a solid foundation...
Dalian Fuchang Chemical Co.,Ltd
- 116011 - Dalian
- +8615542419276
Saturday, August 17, 2019
Quantity : 500kg
We offer different kinds of Station Post Insulator for Substation, such as Circuit Breaker (CB), Post Insulator, Disconnector, Potential Transformer (PT), Surge Arrester, etc. Contact us get more details about Station Post Insulator, such as TDS, Application Method, OEM etc. We can...
Fujian Ruisen New Materials Co., Ltd.
- 364400 - zhangping
- 0597 3271526
Friday, August 16, 2019
Quantity : 80000Pcs - Price : 3-50USD
- Specification of JH-D10 Digital Trimmer 3 Modes Ear Hook Trimmer Hearing Aids Hearing Amplifier - Max Sound Output 128±3dB Voltage D.C.1.4V Sound Gain 57±5dB Battery Type LR44H/A675 Total Harmonic Wave Distortion 500Hz <6% 800Hz <4% 1600Hz <1% Battery capacity/Mah...
Huizhou Jinghao Medical Technology CO., Ltd
- 516000 - Huizhou
- +86 0752 2299187
- +86 18566295705
Friday, August 16, 2019
Quantity : 80000Pcs - Price : 3-50USD
- Specification of JH-D03 BTE FM Balanced Armature Loudspeaker Open Fit Hearing Aid Hearing Amplifier - Max Sound Output 130±3dB Sound Gain 40±5dB Total Harmonic Wave Distortion 500HZ<3%</span> 800HZ<5%</span> 1600HZ<1%</span> Operation Current/mA...
Huizhou Jinghao Medical Technology CO., Ltd
- 516000 - Huizhou
- +86 0752 2299187
- +86 18566295705
Friday, August 16, 2019
Quantity : 80000Pcs - Price : 3-50USD
- Specification of JH-907 ITE Mini Hearing Aid Hearing Amplifier - Max Sound Output 120 ± 5dB Voltage 1.5V Sound Gain ≥35dB/28 Battery size A10 Total Harmonic Wave Distortion ≤5% Battery capacity/Mah 100 Operation Current ≤6mA Operation current/mA 3.5 Frequency...
Huizhou Jinghao Medical Technology CO., Ltd
- 516000 - Huizhou
- +86 0752 2299187
- +86 18566295705
Friday, August 16, 2019
Quantity : 80000Pcs - Price : 3-50USD
- Specification of JH-116 Personal Sound Amplifier Behind The Ear Hearing Aid - Max Sound Output 130 ± 5dB Voltage 1.5V Sound Gain ≥45dB/44 Battery size LR754 Total Harmonic ≤5% Battery capacity/Mah 68 Wave Distortion Operation ≤4mA Operation current/mA 4.5 Current...
Huizhou Jinghao Medical Technology CO., Ltd
- 516000 - Huizhou
- +86 0752 2299187
- +86 18566295705
Friday, August 16, 2019
NH2 HPLC columns refer to the chromatographic columns that use silica gel as matrix carrier to bond amino groups. They are usually used for the analysis of carbohydrate compounds, and the mobile phase is usually methanol, acetonitrile and buffers salt solution. - The cleaning method...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Friday, August 16, 2019
- Category - In terms of the filler type, SPE column can be divided into four applications of silicone bonding matrix, polymer matrix, absorption matrix and specialized columns. Besides, the silicone bonding has four sorts—antiphase(C18 sealing end/uncapped/hydrophile, C8), positive...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Thursday, August 15, 2019
The similarities FLASH and SPE are all column chromatography separation technology. FLASH is a fast separation mode for preparative chromatography, using optimized pre-packed low and medium pressure columns for chromatographic separation. The separation mechanism, stationary phase...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Wednesday, August 14, 2019
Flash column chromatography is an alternative to long column chromatography developed in 1978. This method aims to separate the components from the mixture and thereby purify it. It is built from existing long column chromatography techniques and is time-consuming and often unsatisfactory...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Wednesday, August 14, 2019
Physical properties of the chromatographic column could affect the performance of C18 HPLC columns. - Performance factors of C18 HPLC columns: - Silica gel purity Class A silica gel has high residual silica hydroxyl with a negative charge and high metal content on the acidic surface...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Tuesday, August 13, 2019
Laboratory vacuum filtration equipment is specially designed for laboratory workers to maintain solid-liquid separation of liquid samples. Operation Procedures of Diaphragm Vacuum Pump 1. Put the glass filter flask on the stainless steel workbench, and insert the silica gel plug of...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Monday, August 12, 2019
The rapid chromatographic method is a technology widely used in the separation and purification of active target compounds, such as organic compounds, natural products, and biological macromolecules. Rapid chromatographic method has the advantages of easy-operation, low-price, and fast-analysis...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Monday, August 12, 2019
Solid phase extraction principle Solid phase extraction is a separation technique that combines selective retention, selective elution, and the like. When a complex sample solution passes through the sorbent, the sorbent selectively retains the aimed compound and a small number of...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Friday, August 09, 2019
A gel battery (also known as a "gel cell") is a VRLA battery with a gelified electrolyte; the sulfuric acid is mixed with fumed silica, which makes the resulting mass gel-like and immobile. Gel batteries reduce the electrolyte evaporation, spillage, subsequent corrosion problems and...
Dongjin Power CO., LTD.
- 518000 - Shenzhen
- 86 755 8666 0729
Friday, August 09, 2019
Reversed-phase chromatography (RPC) contains any chromatographic method using a non-polar stationary phase. The word “reverse” has a historical background. In the 1970s, most liquid chromatography was performed on unmodified silica or alumina. Their surface chemistry is hydrophilic...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Thursday, August 08, 2019
Flash columns adopt high-capacity silica gel for precise filling, which has very excellent separation and purification performance. The specific surface area of high-capacity spherical silica gel is 40% higher than that of ordinary spherical silica gel, and the sample loading is twice...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Thursday, August 08, 2019
Most common SPE cartridges are injection syringes made of polyethylene, in which there are two plugs made of polypropylene or fiberglass, with a certain amount of chromatographic adsorbent (filler) between the two plugs. SPE cartridges without sieve plate 1. Avoid “non-specific adsorption” 2...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Monday, August 05, 2019
One of the main factors affecting the life of the liquid chromatographic column is the mobile phase. There are three aspects of the mobile phase factors. The pH value of the Mobile Phase The fillers of different substrates apply to different pH value range. Under normal temperature...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Saturday, August 03, 2019
SPE cartridge can be divided into three classes on the markets: silica-based cartridges, polymer-based cartridges, and adsorption-based cartridges. And here we talk about the three types of silica-based cartridges. The first type is the C18 cartridges. This kind of cartridges bond...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Friday, August 02, 2019
Flash column pressure has something to do with the form of silica gel, the mesh number, the synthesis condition of filler, the condition of column packing, the mobile phase, and the temperature when analyzing. Different manufacturers' new flash columns, their column pressures may...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Thursday, August 01, 2019
There are two different cases of retention time: retention time drift and retention time fluctuations. The former means that the retention time changes only in one direction, while the latter refers to the fluctuation of the retention time without a fixed law. It is often helpful...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Wednesday, July 31, 2019
- The Selection Principle of Silica Gel Column - Commonly, the maximum sample loading volume of a silica gel column is about 1/20 of the volume of the column's silica gel. However, as a practical matter, specific sample loading volume should be decided by each constituent's degree...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Wednesday, July 31, 2019
Solid phase extraction (SPE), developed in the 1970s, can replace the traditional liquid-liquid extraction in many fields and has been applied more and more widely in the laboratory. The common solvent of SPE Hexane, isooctane, tetrahalide carbon, trihalomethane, dihalomethane, tetrahydrofuran...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Tuesday, July 30, 2019
The improper use of chromatographic columns will make the columns decrease or lose effectiveness. Generally speaking, the columns always have problems at the end of them. If we can install a short column with the same stationary phase as the analysis column in front of analysis column...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Friday, July 19, 2019
Bonded-phase chromatography is a liquid-liquid chromatography method in which a stationary phase is covalently bound to a carrier particle, which overcomes the mechanical shock in the distribution chromatography, the constant loss of the stationary phase and the gradual change of...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Monday, July 15, 2019
Laboratory data show that the optimum flow rate of silica gel flash columns is decided by the length and width of columns and the property of gel. To be more specific, longer and narrower columns will provide more theoretical plates which are able to affect the flow rate. When referring...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33