Everything else / Bulk

Flash Column Chromatography

Flash column chromatography is an alternative to long column chromatography developed in 1978.

This method aims to separate the components from the mixture and thereby purify it. It is built from existing long column chromatography techniques and is time-consuming and often unsatisfactory. Briefly, flash column chromatography allows the sample to pass through a gel-filled column that separates the sample.

Still and chromatographic founder Still and colleagues have been using medium- and high-column chromatography instead of long-column chromatography. They decided to combine the two to overcome the shortcomings of long column chromatography and low recovery.

The gel originally used to fill the column was silica gel, which is still widely used. They use gas pressure to push the solvent through a silica gel column and compress the column. The sample is then applied and the sample is passed through the column using the same (may be different, but usually the same) solvent. The purified components or fractions are then collected and the entire process takes approximately 5 – 10 minutes. Usually, a small portion first appears and most of it elutes at the end. The collected fractions were subjected to original analysis by thin layer chromatography (TLC) plates.

Silica gel column chromatography has been widely used in organic chemistry since its inception. However, the guidelines are often loose, driven by personal experience, or not well translated when settings are changed. However, some things are still true. Increasing the sample size will result in a lower resolution. Compared to high-performance liquid chromatography (HPLC), the resolution of flash column chromatography is already moderate, but sufficient for adequate separation, so an increase in the number will only worsen the situation. Second, the optimum flow rate depends on the length and width of the column and the nature of the gel. This is due to the number of plates available, for example, longer and narrower columns will provide more theoretical plates, affecting the flow rate. Finally, the resolution is affected by the stationary phase. It provides better resolution if the stationary phase or the gel arranged on the column is more uniform and has a smaller particle size. The smaller the particle size, the larger the surface area and the higher the resolution.

Manipulating all of these factors to optimize component purity or recovery can be quite complicated because they interact, but have different effects when tested independently. For example, mobile phase selectivity has the greatest impact on resolution, but it depends on column capacity. This, in turn, is affected by the solvent chosen.

Therefore, you need to test or calculate the settings used in the flash column chromatography before starting any real experiments. If you have data from TLC, you can calculate the optimal settings without having to test any of the flash column settings. The low thin layer chromatography delay factor (Rf) provides better separation. Using such data, the amount of solvent required can be calculated because they are inversely proportional to each other and both are related to the column void volume (solvent in the column before sample loading).

In the original method, it is very important to prevent the column from drying out. However, a more user-friendly alternative has been developed since then, called dry column flash chromatography. This method has been adopted by first-time students while still producing better results comparable to analyzing TLC quality. The principle is the same, but the column contains dry silica gel. The powdered xerogel was filled into the column by suction, finally obtaining a uniform bed of about 1 cm for the solvent and the sample. The column was also eluted by aspiration and dried after each fraction.

Location : Xi'an City , Shaanxi Province, P.R.China, 710077 Xi'an,
Contact : Bruce Lu, +86 29 89284429

Good deal: buying from seller

Visit our guide for a secure transaction! Under no circumstances Algomtl can be held responsible for the content of the ads published. Only the sellers and buyers responsability is involved in case of dispute.
We invite you to read our terms of use. You can also visit our FAQ section and see our information section on the risks associated with counterfeiting.
This page is about importers and exporters of
Flash Column Chromatography

Search in a category : Everything else / Bulk
Search in a category :
flash, chromatography, column
France 10300 Clothes
Official Manchester United Soccer Jersey Red 2016

Sunday, April 21, 2024

Price : 12,90 €

Soccer jersey with shorts Official MANCHESTER UNITED All models Clubs Foreigners available on our website. Sold for professional € 12.90 / pcs per 36 pieces in carton mixture of sizes and clubs possible. This price is for 36 pcs, non-negotiable for this quantity, the price is...

Bkk-sport Ltd

  • Bkk-Sport
  • 10300 - Bangkok
  • via le site
  • www bkk sport com
Hong Kong 250200 Equipment goods
Co2 mig welding wires

Tuesday, November 11, 2014

copper wire for saleER70S-6,co2 mig welding wires Shandong Zander Sourcing Company Limited 1.place of orginal: Shandong,China. 2.Brand name: Zander 3.Material: CO2 4.Diameter: 1.0mm 5.Standard: AWSER70S-6 6.Specifications : er70s-6 welding wire ;fast depositing speed;high...

Shandong Zander Resourcing Co.Ltd

Thailand 15140 Food
Sunflower Oil, Soybean Oil, Palm Oil for Sale

Sunday, July 26, 2015

Specific Gravity at 20c; 0.916-0.923 Refractive Index at 20c; 1472-1474 Iodine Value; 120-143 Unsaponification; 2.5 Max Free Fatty Acid; 0.1% Max. as Oleic Acid Peroxide Value; 1 Max. (meg/kg) Color; Max. 2 Red (on 5 Lovibond cell) Moisture; 0.1% Max Appearance; Clear and...

TRADEX GROUP CO LTD

  • 15140 - opburi
  • +6661409539