Construction goods

Water content test in lubricant oil

Ⅰ.Product efficacy:  

Main Functions: ◆Determining the degree of pollution in lubricant within 5 minutes;
◆Detecting percentage of water content in the lubricant within 3 minutes;
◆Detecting metal particles beyond 60um;
◆Determining the new purchased lubricant is qualified or not;
◆Printing the result after finishing the detecting
Product Advantages: ◆Maximisation and safe extension of intervals between oil changes.
◆The early detection and prevention combination of mechanical failure.
◆Avoidance of unnecessary engine damage resulting from overly used lubricants.
◆Reduce the number of costly and unnecessary laboratory analysis of oil Samples.

Ⅱ、Product Description:  
The type of THY-21CE oil quality analyzer is an upgrade version of the type of THY-21A oil quality detector. Due to Install a large-screen monitor to realize operating prompt and Chinese characters of each function, convenient to read various data. It is installed a micro printer and uses a high-precision A / D conversion circuit, so that the analyzer repeatability is better. When the power of battery is low, the buzzer will alarm automatically and prompt. The analyzer has a dual function of DC and AC (DC can work continuous for 28 hours), in no man operation condition will shut down automatically; When AC power work can charge. The analyzer has exquisite appearance, easy to operate, suitable for on-site and field operations.

alt

Product Features Technical Specifications
◆Battery / power supply operation;
◆The index in the memory of more
than 200 kinds of samples oil;
◆Portable: only 5.0 kg.
Range ± 199.9
Repeatability ≤ ± 2%
Temperature -15℃~ +55℃
Power ≤5W
Voltage 220V±10%
N.W. 5kg
Size 328×210×130mm
Overall Power Consumption: ≤ 5W (without printing)


alt
alt
Visually display the testing results by full chinese character LCD. high sensative sensor
alt alt
Water-proof membrane,oil-proof soft keyboard. output the data at anytime,conviniently record and manage the data by the micro printer.
Ⅲ.Main Benefits:  

Battery / power supply operation;
The index in the memory of more than 200 kinds of samples oil;
Portable: only 5.0 kg.

Ⅳ.Main Benefits:  

Using Manual:
4.1 Quick Test【QT】
4.1.1 Placed the analyzer on a horizontal table, open the box cover.
4.1.2 Connected 220V power, open the "power" switch, the green light is on. Press the 【ON】 button, the analyzer
will test successful on self. The LCD screen shows "Welcome to use THY-21CE. TIANHOU CO.LTD
Version1.3", then enter into the standby condition, please start testing after the analyzer was preheated for
more than 10 minutes.
4.1.3 Adjust the "zero" point:
(1) Using petroleum ether with 60 ℃ -90 ℃ boiling clean cavity ,then use dry cotton wipe clean (twice).
(2) Press 【MZ】 button, the LCD screen shows "Put Pure Oil" then enter into standby condition, drip 3-5 drops
(the same type and batch as the measured oil) pure oil into oil cavity.
(3)When the oil get fully contact in oil cavity, press 【Enter】 button ,the analyzer enter into the state of adjusting
zero ,and the red light is on, the LCD screen shows“MZ_VOL: XX.X.”
(4) Adjust manually the zeroing knob, and make the LCD screen displayed value decreases. When the
displayed value is equal to or less than ± 0.2 , the buzzer ring and the LCD screen shows "MZ_VOL: XX.X
MZ... .OK!!" After adjusting zero is finished, at the same time back to "THY-21C", please press 【MZ】 button
three times in order to ensure the accuracy of adjusting zero .
(5) After using dry cotton ball to wipe oil cavity, drop petroleum into the oil cavity, and later use dry cotton ball
to wipe the oil cavity (twice).
4.1.4 Press 【QT】 button twice, the LCD screen shows "Quick Test , Put old oil", then wait for order.
4.1.5 Drip 3-5 drops of the measured oil into the oil cavity, when the oil get fully contact in oil cavity, immediately
press the 【Enter】 button, the red light is on.
4.1.6 The LCD screen shows "Quick Test .T_VOL: XX.X Check OK!!" You can judge oil status by comparing the test
data with scrap index reference value
4.1.7 After finishing the testing, then press the 【Reset】 button or any button to back to standby state, clean the oil
cavity with petroleum for the use of next time.
4.2 Standard Test (ST)
4.2.1 Adjusting zero and quick test's are the same, please refer to 4.1.3.
4.2.2 Press 【ST】 button, the LCD screen shows "Input NUM".
4.2.3 Press the number button 【0】 - 【9】 and enter the four serial number of the measured oil, press 【Enter】
button. If the number is correct, the screen shows "Put Old Oil" if the number is incorrect, the screen shows
“Num. error”, please input oil number again.
4.2.4 Drip 3-5 drops of the measured oil into the oil cavity, when the oil get fully contact in oil cavity, immediately
press the 【Enter】 button to enter into the detecting condition, the red light is on. The LCD shows “the
values ​​XX.X .
4.2.5 Press 【Enter】 button, the LCD screen shows “Input NUM.XXXX Put old oil T_Vol: XX.X TYPEANXX
R_VOL: XX.X TEST OK!!” When LCD screen shows “pure oil”, it indicates the measured oil can continue to
use; When showing “useless”, it indicates the measured oil is beyond the standard and should be changed;
when showing "test may ", it indicates the measured oil is about to be scrapped.
4.2.6 Press 【Reset】 button or 【Enter】 button and back to "THY-21CE ".
4.2.7 After finishing the testing, clean the oil cavity with petroleum for the use of next time.


4.3 Water Test (WT)
4.3.1 Adjust the "zero" point:
(1)Using petroleum ether with 60 ℃ -90 ℃ boiling clean oil cavity ,then wipe the oil cavity with dry cotton
(twice).
(2)Press the 【WT】 button, LCD screen shows “Water Test Zero ADJ .Put Pure Oil", drip 3-5 drops (the same
model and lot as the measured oil) pure oil into oil cavity.
(3)When the oil get fully contact in oil cavity, press 【Enter】 button, the analyzer enter into adjusting zero
conditions.
(4)Adjust manually the zeroing knob, and make the LCD screen displayed value decrease. When the
displayed value is equal to or less than ± 0.2 , the buzzer ring, then LCD screen shows "Water Test.
MZ_VOL: XX.X MZ... .OK!!". Please press 【MZ】 button three times in order to ensure the accuracy of
adjusting zero.
(5)Use dry cotton ball to wipe oil cavity, drop petroleum into the oil cavity, and later use dry cotton ball to wipe
the oil cavity (twice).
4.3.2 Press 【Enter】 button, the LCD shows “Water Test. Put old oil”
4.3.3 As soon as possible drop full the measured oil in the oil cavity, immediately press 【Enter】 button, the red
light is on and enter into the water testing status. The analyzer takes sample data one time every 5 seconds.
The LCD screen shows "Water Test. T_VOL: XX.X.”
4.3.4 After three minutes the red light is off, the LCD screen shows the measuring results“Water Test. Water
X.XX%, Check OK!!”
4.3.5 After finishing the testing, and then press the 【Reset】 button or any button to return standby state, clean the
oil cavity until the next use.
4.4 Print Function
After finishing any tests, you can print the result according to your needs, the operations are as follow:
4.4.1 Press 【print】 button, the LCD screen shows "year", you can enter the year, four serial number, such as
the 2012.
4.4.2 After finishing, press 【Enter】 button, LCD screen shows "Month", you can enter the month, when the month
is less than 10 ,please add "0" such as "07"and "08".
4.4.3 After finishing, Press 【Enter】 button, LCD screen shows "DATE"
you can enter the date, when the date is less than 10 hours ,please add "0"such as"02", "03".
4.4.4 After finishing, press 【Enter】 button to print the testing result.
5、Auxiliary Function
5.1 Browse Date (BD)
5.1.1Under "THY-21CE" standby status, press 【BD】 button, you can query the data.
5.1.2The LCD screen shows "Input Num", press 【0】 - 【9】 button to input the oil number, and press 【Enter】
button. If you input the number is correct, the LCD screen will show oil number, the scrapped lower limit and
upper limit.
5.1.3 If the oil number is incorrect, the LCD screen shows" num error," you must renew input the number.
5.1.4 Press 【Enter】 button to exit from BD and back to "THY-21CE".
5.2 Reset:
When your device is dead for any reason, or you want to end your certain operations when it is necessary,
you can press "RESET".
5.3 The backlight off
Press 【 LT】 button can turn on or off the backlight of the LCD screen.
5.4 Charging
(1) When AC power supply, press the 【charge】 switch to charge the battery.
(2) The battery power supply, when the LCD screen shows "VOLT LOW!" ,you should charge it immediately.
(3) The host is connected to 220V alternating current with power line, press the 【charge】 switch to start
charging, charging 10 hours is appropriate.
6. Attention
6.1 Using petroleum ether with 60 ℃ -90 ℃ boiling clean oil cavity, you need wait petroleum ether evaporation
complete then dropped the oil to oil cavity .
6.2 Adjusting zero sample oil must be the same type and batch with the measured oil.
6.3 The old oil should be extracted even, you'd best use sampler.
6.4 If the measured pollution value is less than the oil-changing index minimum, the measured oil can continue
to use; if the value is between minimum value and maximum value for changing oil, the measured oil can
be scrapped or be use continually; if the value is greater than the oil-changing index maximum, the
measured oil can be scrapped
.

Ⅴ.Applications:  
For the present THY-21CE oil quality analyzer is applied to various fields such as aerospace, oil field, ports, transport, mine, electricity, metallurgy, chemical industry and engineering plant., etc.
alt alt alt alt alt alt alt

Location : , 710075 Xi'an,
Contact : Lawrence Chang, 86 29 86691978

Good deal: buying from seller

Visit our guide for a secure transaction! Under no circumstances Algomtl can be held responsible for the content of the ads published. Only the sellers and buyers responsability is involved in case of dispute.
We invite you to read our terms of use. You can also visit our FAQ section and see our information section on the risks associated with counterfeiting.
This page is about importers and exporters of
Water content test in lubricant oil

Search in a category : Construction goods
Search in a category :
content, test, lubricant, water
France 75008 Craft
Fouta 100% cotton personalized according to the décor choice & Fouta Deco

Saturday, October 07, 2017

Price : DEPENDING ON QUANTIT

La fouta is a linen fabric woven in Tunisia for many decades. Women compete to possess the most beautiful and do not hesitate to personalize it. Today the fouta has invaded Europe and has adapted to our current ways of life. In plain or striped patterns, in a range of trendy and vivid...

Decodarg

  • 75017 - PARIS
  • 06 63 49 36 72
Vietnam 700000 Food
Canned Coconut Milk / Cream

Wednesday, December 04, 2024

Quantity : 1XCONT20 - Price : 16.5$/CARTON

Frozen coconut cream is extracted from white coconut meat without using additives and preservatives. Coconut Cream is frozen to keep the original nutrition and flavor of the coconut. - Extracted from the grated flesh of fresh coconut white meat. - Available with fat 17% - 19% in...

Viet Delta Corporation

  • Vince Ha
  • 700000 - Ho Chi Minh
  • +841253335112
  • whatsapp: +841253335112
Intel Core i9 10920 Core i9 3,5 GHz - Skt 2066 Cascade Lake BX8069510920X

Saturday, June 18, 2022

Quantity : 100

Intel Core i9-10920X. Famille de processeur: Intel® Core™ i9 série X, Socket de processeur (réceptable de processeur): LGA 2066 (Socket R4), composant pour: PC. Canaux de mémoire: Quad-channel, Mémoire interne maximum prise en charge par le processeur: 256 Go, Types de mémoires pris...

MaKant Europe GmbH & Co. KG

  • 60386 - Frankfurt am Main
  • +49 (69) 9 150 750 14