Solution For Bubble Overflow In HPLC Column

There are bubbles in the mobile phase, the pump is turned off, the pressure relief valve is opened, the purge button is turned on, the degas is cleaned, the bubbles are continuously ejected from the HPLC column, and the mobile phase enters the mobile phase. No matter how many times the purge button is turned on, the continuously generated bubbles cannot be removed.

Syringe filter is immersed in a buffer such as ammonium acetate for a long time. The inside of the filter grows due to the growth of mold, forming a cluster of bacteria, blocking the filter. The buffer is difficult to smoothly pass through the HPLC column, and the air enters the mobile phase through the filter under the pressure of the pump.

The treatment filter is immersed in a 5% nitric acid solution and ultrasonically cleaned for a few minutes. The filter can also be immersed in a 5% nitric acid solution for 12 to 36 hours, gently vortexed several times, and then the filter is washed several times with pure water. Open the pressure relief valve, open the purge button to clean the degassing.

If there are still bubbles emerging from the HPLC column continue to soak the filter in a 5% nitric acid solution. If there are no bubbles, the filter will emerge from the filter. The internal mold flora has been destroyed by nitric acid and the mobile phase can pass through the filter smoothly. Open the pressure relief valve, turn on the pump, adjust the flow rate to 1.0 ~ 3.0ml / min, rinse the filter with pure water for about 1 hour. The filter can be cleaned. Close the pressure relief valve and rinse with pure methanol for half an hour.

Location : Xi'an City , Shaanxi Province, P.R.China, 710077 Xi'an,
Contact : Bruce Lu, +86 29 89284429

Good deal: buying from seller

Visit our guide for a secure transaction! Under no circumstances Algomtl can be held responsible for the content of the ads published. Only the sellers and buyers responsability is involved in case of dispute.
We invite you to read our terms of use. You can also visit our FAQ section and see our information section on the risks associated with counterfeiting.
This page is about importers and exporters of
Solution For Bubble Overflow In HPLC Column

Search in a category : Everything else / Bulk
Search in a category :
overflow, hplc, column, bubble, solution
France 59590 B2B Services
ETM DIN GATE VALVE F7

Wednesday, September 14, 2016

Quantity : 5000 - Price : 50,00 €

Gate Valves (F7 Type) DIN Standard F7 Gate valves / (Length acc.to DIN EN 558-1,face to face series 26 ) DIN F7 Gate valve DIN Absperrschieber F7 DIN Válvulas de compuerta F7 DIN F7 šoupátko stavební délka dle DIN EN558-1 serie 26 DIN Standard F7 sluseventil (lengde iht. DIN EN 558-1...)

ETM Armaturen

  • 59590 - Henri Durre
  • 86 577 67953935
United Kingdom CM23 2JP Phones
Apple iPhone 5s - 32 GB - Space Gray - Factory Unlocked

Friday, March 04, 2016

Quantity : 150 - Price : 280,00 €

You check your iPhone dozens and dozens of times a day, probably more. Entering a passcode each time just slows you down. But you do it because making sure no one else has access to your iPhone is important. With iPhone 5s, getting into your phone is faster, easier, and even a little futuristic...

Electronics Design Services

  • CM23 2JP - Hertfordshire
  • +447405858765
France 510800 Raw materials
Liquid silicone rubber

Wednesday, April 08, 2015

Quantity : 100 grams - Price : 7USD

- Liquid silicone rubber Specifications - mold liquid silicone rubber 1.favorable hardness 2.less than 2% shrinkage 3.catalyst: odorless Liquid silicone rubber Application: 1.Unsaturated polyester resins, epoxy resins, polyurethane resins. 2.Polyurethane elastomers. 3.Natural...

Guangzhou OTT New Materials Co.,Ltd.

  • 510800 - Guangzhou
  • 86 020 86819712