Solution For Bubble Overflow In HPLC Column
There are bubbles in the mobile phase, the pump is turned off, the pressure relief valve is opened, the purge button is turned on, the degas is cleaned, the bubbles are continuously ejected from the HPLC column, and the mobile phase enters the mobile phase. No matter how many times the purge button is turned on, the continuously generated bubbles cannot be removed.
Syringe filter is immersed in a buffer such as ammonium acetate for a long time. The inside of the filter grows due to the growth of mold, forming a cluster of bacteria, blocking the filter. The buffer is difficult to smoothly pass through the HPLC column, and the air enters the mobile phase through the filter under the pressure of the pump.
The treatment filter is immersed in a 5% nitric acid solution and ultrasonically cleaned for a few minutes. The filter can also be immersed in a 5% nitric acid solution for 12 to 36 hours, gently vortexed several times, and then the filter is washed several times with pure water. Open the pressure relief valve, open the purge button to clean the degassing.
If there are still bubbles emerging from the HPLC column continue to soak the filter in a 5% nitric acid solution. If there are no bubbles, the filter will emerge from the filter. The internal mold flora has been destroyed by nitric acid and the mobile phase can pass through the filter smoothly. Open the pressure relief valve, turn on the pump, adjust the flow rate to 1.0 ~ 3.0ml / min, rinse the filter with pure water for about 1 hour. The filter can be cleaned. Close the pressure relief valve and rinse with pure methanol for half an hour.
Contact : Bruce Lu, +86 29 89284429
Good deal: buying from seller
We invite you to read our terms of use. You can also visit our FAQ section and see our information section on the risks associated with counterfeiting.
|
This page is about importers and exporters of Solution For Bubble Overflow In HPLC Column Search in a category : Everything else / Bulk Search in a category : hplc, column, solution, overflow, bubble |
Wednesday, September 14, 2016
Quantity : 5000 - Price : 50,00 €
Gate Valves (F4 Type) DIN Standard F4 Gate valves / (Length acc.to DIN EN 558-1,face to face series 14 ) DIN F4 Gate valve DIN absperrschieber F4 DIN Válvulas de compuerta DIN F4 šoupátko stavební délka dle DIN EN558-1 serie 14 DIN Standard F4 sluseventil (lengde iht. DIN EN 558-1...)
ETM Armaturen
- 59590 - Henri Durre
- 86 577 67953935
Friday, June 05, 2009
Sodimar is a french company specialized in the manufacture and distribution of various materials for construction and landscape gardener companies, etc... We are also looking for retailers in european , american, asian countries, etc...(for the small violet border machine) Distribution...
Tuesday, September 08, 2015
Module parameters HD-960P-38*38mm 1.3megapxel low-illumination HD web camera Network Camera - Sensor type 1/4 inch、1.3megapixel , CMOS low-illumination width dynamic sensor - Minimum illumination Color: 1 Lux/F1.2, black and white: 0.02Lux/F1.2 - Electronic shutter 1/5 second ~ 1/50...
ZT Technology Group Ltd.
- ellazhan
- 852 - Fo Tan
- +85 2 26 75 75 58