Shine i1910 Fully Automatic Chemiluminescence Immunoassay Analyzer
Shine i1910 is a fully automatic and simple-to-use benchtop chemiluminescence immunoassay analyzer with a throughput of 120 tests per hour. Based on various modes of antigen-antibody immunoreactivity and with paramagnetic particles as a carrier, i1910 utilizes the indirect chemiluminescence reaction of AMPPD with alkaline phosphatase to realize catalytic cracking of AMPPD under the action of enzymes. As a fully automated immunoassay analyzer with high quality, Shine i1910 with the characteristics of simplicity, reliability and flexibility, which can help optimize your laboratory analysis performance.
Automated Clia Analyzer Features
◆ Innovative design: Incubation, washing and detection all-in-one.
◆ Fast: first result in 15 mins.
◆ Good repeatability: Batch CV≤8%.
Automatic Chemiluminescence Immunoassay Analyzer Specifications
|
Sample Type |
Human serum and plasma samples |
|
Throughput |
Test speed up to 120 tests / hour |
|
Assay cup |
Disposable assay cup |
|
Sample position |
30 |
|
Reagent position |
10 |
|
Reagent refrigeration |
24h refrigeration, reagent disk temperature: 2 °C ~8 °C |
|
Temperature stability of reaction disk |
37 ℃± 0.3 ℃, and the temperature fluctuation should not exceed 0.2℃ |
|
Repeatability within batch |
CV ≤ 8% |
|
Carry-over |
≤10-5 |
|
Linear correlation |
r ≥ 0.99, the concentration range is not less than 2 orders of magnitude |
|
Dimensions (mm) L×W×H |
433×679×638 |
|
Net weight (kg) |
62 |
Clia Immunoassay Analyzer Test Items
|
Tumor Markers |
|
|
Name |
Abbr. |
|
Carcinoembryonic Antigen Quantitative Diagnostic Kit (CLIA) |
CEA |
|
Neuron-specific Enolase Quantitative Diagnostic Kit (CLIA) |
NSE |
|
Carbohydrate Antigen 19-9 Quantitative Diagnostic Kit (CLIA) |
CA19-9 |
|
Carbohydrate Antigen 15-3 Quantitative Diagnostic Kit (CLIA) |
CA15-3 |
|
Carbohydrate Antigen 50 Quantitative Diagnostic Kit (CLIA) |
CA50 |
|
Cytokeratin 19-fragments Quantitative Diagnostic Kit (CLIA) |
CYFRA21-1 |
|
Cancer Antigen 125 Diagnostic Kit (CLIA) |
CA125 |
|
Fertility |
|
|
Name |
Abbr. |
|
Estradiol Quantitative Diagnostic Kit (CLIA) |
E2 |
|
Luteinizing Hormone Quantitative Diagnostic Kit (CLIA) |
LH |
|
Follicle Stimulating Hormone Quantitative Diagnostic Kit (CLIA) |
FSH |
|
Prolactin Quantitative Diagnostic Kit (CLIA) |
PRL |
|
Testosterone Quantitative Diagnostic Kit (CLIA) |
TES |
|
Total β Human Chorionic Gonadotrophin Quantitative Diagnostic Kit (CLIA) |
Tβ-hCG |
|
Progesterone Quantitative Diagnostic Kit (CLIA) |
PROG |
|
Placental Growth Factor Diagnostic Kit (CLIA) |
PLGF |
|
Soluble Fms-like Tyrosine Kinase-1 Diagnostic Kit (CLIA) |
sFlt-1 |
|
Pernatal Screening |
|
|
Name |
Abbr. |
|
Alpha-Fetoprotein Quantitative Diagnostic Kit (CLIA) |
AFP |
|
Alpha-fetoprotein Quantitative Diagnostic Kit (CLIA) |
Ps-AFP |
|
Pregnancy Associated Plasma Protein A Diagnostic Kit (CLIA) |
PAPPA |
|
Free β Human Chorionic Gonadotrophin Diagnostic Kit (CLIA) |
freeβ-HCG |
|
Free Estriol Diagnostic Kit (CLIA) |
FE3 |
|
Infectious Disease |
|
|
Name |
Abbr. |
|
2019 Novel Coronavirus (2019-nCoV) Antigen Qualitative Diagnostic Kit (CLIA) |
2019-nCoV |
|
2019-nCoV Neutralizing Antibody Detection Kit (CLIA) |
2019-nCoV Nab |
|
Anemia |
|
|
Name |
Abbr. |
|
Ferritin Quantitative Diagnostic Kit (CLIA) |
Fer |
|
Kidney Function |
|
|
Name |
Abbr. |
|
Neutrophil Gelatinase-Associated Lipocalinn Quantitative Diagnostic Kit (CLIA) |
NGAL |
Chemiluminescence Immunoassay Analyzer Principle
Based on various antigen-antibody immunoreaction modes, the full automatic hemiluminescence immunoassay analyzer takes paramagnetic particles as the carrier, and makes use of the direct chemiluminescence method of acridinium ester. It produces unstable intermediates in excited state under the action of free energy released in chemical reaction. When the intermediates get back to the ground state from the excited state, the photons with the same energy level are released. At this point, it measures such photons and thus conducts the quantitative analysis. The luminescent intensity of the reaction is proportional to the concentration in the sample within the detection range.
If you want to know more kinds of molecular diagnostic system, please visit our website.
Contact : Gene Daan , 86 20 32068126
Good deal: buying from seller
We invite you to read our terms of use. You can also visit our FAQ section and see our information section on the risks associated with counterfeiting.
|
This page is about importers and exporters of Shine i1910 Fully Automatic Chemiluminescence Immunoassay Analyzer Search in a category : Everything else / Bulk Search in a category : automatic, chemiluminescence, fully, immunoassay, analyzer, i1910, shine |
Tuesday, November 25, 2025
Quantity : 1
Potato cutter spiral cutting plane model is designed for cutting potato chips, cut water and savored, is a cutter with adjustable cutting easy handling. - Funcicion built in aluminum and stainless steel. Potatoes cutter - Easy adjustment and blade change. - Input and output...
Mafrigarlo
- mafrigarlo
- 28970 - humanes de madrid
- 91 6971596
Tuesday, November 25, 2025
▲VE-30RFM RX (Front / Rear) ▲VE-30RFM TX (Front / Rear) VE-30RFM HDMI to RF Matrix Extender is designed to convert HDMI signal to HD digital TV signal based on DVB-T CATV signal, it uses 64QAM mode to realize the HD digital TV signal conversion and transmit via coaxial cables for...
Meicheng Audio Video Co., Ltd.
- meicheng
- 23511 - New Taipei City
- 886 2 82280311
Thursday, June 16, 2016
Application Method 1. Glue is applied on textile or leather. 2. Patterned or fully coated glue is fixed by heat before foil transfer properly. 3. Stamping the foil ,heat: 130C-150C, pressure 4-6 bar, touch time 3-5 s. 4. Discard the carrier film after stamping process.Different...
UES Makine Tekstil Inşaat ve Gida San.Tic.Ltd.Şti
- 34510 - Istanbul
- +902125571040