Rotatable Sphincterotome
Rotatable sphincterotome is used for cannulation of the ductal system and for sphincterotomy, if preloaded, also aids ERCP operation in the stenosis of bile duct difficult stricture.
Features of Rotatable Sphincterotome
Tapered tip enables easy cannulation.
Insulating coating minimizes the risk of tissue damage as well as endoscopic contact.
Pre-curved tip assists cannulation efficiency and reduce operation time.
Colored markers for precise positioning under endoscopic view.
Double-lumen and triple lumen sphincterotome are both available.
Preloaded with 0.035" LeadCross.
360° 1: 1 rotation facilitates cannulation.
Specification of Rotatable Sphincterotome
Rotatable Sphincterotome
|
REF |
Structure |
Tip Length |
Cutting Length |
Working Length |
Compatible Guidewire |
Minimum Working Channel (mm) |
Unit/Box |
|
standard |
(mm) |
(mm) |
|||||
|
RST0425N |
3-lumen |
4 |
25 |
1900 |
0.035” |
2.8 |
1 |
|
RST0430N |
3-lumen |
4 |
30 |
||||
|
RST0725N |
3-lumen |
7 |
25 |
||||
|
RST0730N |
3-lumen |
7 |
30 |
Rotatable Sphincterotome (Preassembled with Guidewire)
|
REF |
Structure |
Catheter |
Tip Length |
Cutting wire Length |
Minimum Working Channel (mm) |
Guide Wire |
Unit/Box |
||||
|
Standard |
Outer Diam. |
Length |
(mm) |
(mm) |
Diam. (inch) |
Length (mm) |
Tip Shape |
Hardness |
|||
|
(mm) |
(mm) |
|
|
||||||||
|
RST0425NGW0206 |
3-lumen |
2.4 |
1900 |
4 |
25 |
2.8 |
0.035 |
4500 |
Straight |
Normal Stiff |
1 |
|
RST0430NGW0206 |
3-lumen |
2.4 |
1900 |
4 |
30 |
0.035 |
4500 |
||||
|
RST0725NGW0206 |
3-lumen |
2.4 |
1900 |
7 |
25 |
0.035 |
4500 |
||||
|
RST0730NGW0206 |
3-lumen |
2.4 |
1900 |
7 |
30 |
0.035 |
4500 |
||||
|
RST0425NGW0230 |
3-lumen |
2.4 |
1900 |
4 |
25 |
0.035 |
4500 |
Super Stiff |
|||
|
RST0430NGW0230 |
3-lumen |
2.4 |
1900 |
4 |
30 |
0.035 |
4500 |
||||
|
RST0725NGW0230 |
3-lumen |
2.4 |
1900 |
7 |
25 |
0.035 |
4500 |
||||
|
RST0730NGW0230 |
3-lumen |
2.4 |
1900 |
7 |
30 |
0.035 |
4500 |
||||
Comparison Between a Rotatable Sphincterotome and a Conventional Sphincterotome
The conventional sphincterotome consists of a metal wire with insulating coating, with the distal 20–30 mm of wire exposed, and a short radio-opaque, tapered tip. Cannulation is usually attempted with a sphincterotome at present time. The conventional sphincterotome is designed to perform sphincterotomy at the 12 o'clock orientation, while a rotatable sphincterotome for ERCP in B-II patients or when cannulation/therapeutic interventions entails orientation other than the standard 11–1 o'clock position.
As one of endoscopy device companies, we will do our best to meet all the needs of customers.
Contact : med leomed, 0519 85150730
Good deal: buying from seller
We invite you to read our terms of use. You can also visit our FAQ section and see our information section on the risks associated with counterfeiting.
|
This page is about importers and exporters of Rotatable Sphincterotome Search in a category : Medical Search in a category : rotatable, sphincterotome |
Thursday, March 10, 2016
Introduction: WT2080 LED Power Driver Test Instrument is the comprehensive test instrument for LED drive power which is according to GB/T 24825-2009 and IEC 62384: 2006. It can measure the following parameters: Input Characteristics Test (AC&DC), Output Characteristics Test (AC...)
Lisun Electronics (Shanghai) Co., Ltd.
- 201803 - Shanghai
- +86 021 51083341
- +86 18917996096
Thursday, March 10, 2016
Introduction: JL-X waterproof test system is according to IEC60529, IEC60598, IEC60335 and IEC 60034-5: 2000. The JL-X includes the following test grades: IPX1, IPX2, IPX3, IPX4, IPX5, IPX6, IPX7 and IPX8 (Refer to page 51 of IEC60529). It is widely used in the authentication test...
Lisun Electronics (Shanghai) Co., Ltd.
- 201803 - Shanghai
- +86 021 51083341
- +86 18917996096
Tuesday, June 09, 2015
Product Structure: 1.The main part of the dehydrator is a filter device that a screw runs through the stacked fixed rings and moving ring. 2.The small gaps between fixed rings and moving ring can filter the sludge, and the lumenbetween screw and rings is filled with polymer grains...
SHANGHAI KING INT SUPPLY CHAIN MANAGEMENT CO., LTD
- mniandou2
- 200122 - SHANGHAI
- 86 21 58921782
- 86 18817428200