Medical
Rotatable Sphincterotome
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
REF |
Structure |
Tip Length |
Cutting Length |
Working Length |
Compatible Guidewire |
Minimum Working Channel (mm) |
Unit/Box |
|
standard |
(mm) |
(mm) |
|||||
|
RST0425N |
3-lumen |
4 |
25 |
1900 |
0.035” |
2.8 |
1 |
|
RST0430N |
3-lumen |
4 |
30 |
||||
|
RST0725N |
3-lumen |
7 |
25 |
||||
|
RST0730N |
3-lumen |
7 |
30 |
Rotatable Sphincterotome (Preassembled with Guidewire)
|
REF |
Structure |
Catheter |
Tip Length |
Cutting wire Length |
Minimum Working Channel (mm) |
Guide Wire |
Unit/Box |
||||
|
Standard |
Outer Diam. |
Length |
(mm) |
(mm) |
Diam. (inch) |
Length (mm) |
Tip Shape |
Hardness |
|||
|
(mm) |
(mm) |
|
|
||||||||
|
RST0425NGW0206 |
3-lumen |
2.4 |
1900 |
4 |
25 |
2.8 |
0.035 |
4500 |
Straight |
Normal Stiff |
1 |
|
RST0430NGW0206 |
3-lumen |
2.4 |
1900 |
4 |
30 |
0.035 |
4500 |
||||
|
RST0725NGW0206 |
3-lumen |
2.4 |
1900 |
7 |
25 |
0.035 |
4500 |
||||
|
RST0730NGW0206 |
3-lumen |
2.4 |
1900 |
7 |
30 |
0.035 |
4500 |
||||
|
RST0425NGW0230 |
3-lumen |
2.4 |
1900 |
4 |
25 |
0.035 |
4500 |
Super Stiff |
|||
|
RST0430NGW0230 |
3-lumen |
2.4 |
1900 |
4 |
30 |
0.035 |
4500 |
||||
|
RST0725NGW0230 |
3-lumen |
2.4 |
1900 |
7 |
25 |
0.035 |
4500 |
||||
|
RST0730NGW0230 |
3-lumen |
2.4 |
1900 |
7 |
30 |
0.035 |
4500 |
||||
Comparison Between a Rotatable Sphincterotome and a Conventional Sphincterotome
The conventional sphincterotome consists of a metal wire with insulating coating, with the distal 20–30 mm of wire exposed, and a short radio-opaque, tapered tip. Cannulation is usually attempted with a sphincterotome at present time. The conventional sphincterotome is designed to perform sphincterotomy at the 12 o'clock orientation, while a rotatable sphincterotome for ERCP in B-II patients or when cannulation/therapeutic interventions entails orientation other than the standard 11–1 o'clock position.
As one of endoscopy device companies, we will do our best to meet all the needs of customers.
Good deal: buying from seller
|
This page is about importers and exporters of Rotatable Sphincterotome Search in a category : Medical Search in a category : sphincterotome, rotatable |
Wednesday, December 10, 2014