Low Temperature Chiller LN -60-10
We know that the low temperature chillers are complicated equipment. Even the switch process, if not according to the standard of operation or with no special maintenance, will inevitably lead to a decline in the refrigeration efficiency of the low temperature chillers and will greatly reduce the service life of the them. Here, we will talk about major attention matters when enterprises use low temperature chillers!
1. Refrigerant leakage
Refrigerant leakage will not only affect the refrigeration efficiency of low temperature chillers, but also affect the health of people in and out of the engine room, so the issue of refrigerant leakage must be noted.
2. Pay attention to the load of the low temperature chillers
The large load of low temperature chillers, or overload phenomenon which is more than the rated load, will bring about serious problems including refrigeration efficiency decline, bigger noise, bigger vibration amplitude, excessive consumption of resources, decline in service life and so on which need to pay attention to!
3. Temperature and pressure
It can be said that the parameters related to temperature and pressure are the most important parameters of low temperature chillers. Enterprises should pay attention to the parameters related to the temperature and pressure of the low temperature chillers, and solve them in time, so as to avoid affecting the normal operation of the low temperature chillers.
Paying attention to the points mentioned above has extraordinary importance for extending the service life of low temperature chillers ,and improving the refrigeration efficiency and the use safety of low temperature chillers.
-60℃~-10℃
Technical Parameters:
Low circulator, Low temp circulator, Constant temp circulator, Low circulator, Low temp, circulation bath, Circulators bath, Circulation bath, Circulators, Chiller, Cooling circulators, Cooling bath circulators, Cooling thermostat, Refrigeration bath circulators, Refrigeration circulator, Refrigeration thermostats, Refrigeration bath circulator, Low temp freezer, Freezer, Low freezer, Low chiller, Freezer chiller, Cold trap, Immersion cooler, Low temp bath, Bath thermostats.
Model | LN-6W | LN-10W | LN-15W | LN-20W | LN-30W | LN-40W | LN-60W | LN-90W | LN-120W | LN-180W |
Temperature Range | -60°C~ -10°C | |||||||||
Cooling Capacity At -40°C |
12kw | 20kw | 30kw | 40kw | 60kw | 80kw | 120kw | 180kw | 240kw | 360kw |
10320Kcal/h | 17200Kcal/h | 25800Kcal/h | 34400Kcal/h | 51600Kcal/h | 68800Kcal/h | 103200Kcal/h | 154800Kcal/h | 206400Kcal/h | 309600Kcal/h | |
Cooling Capacity At -55°C |
6kw | 10kw | 15kw | 20kw | 30kw | 40kw | 60kw | 90kw | 120kw | 180kw |
5160Kcal/h | 8600Kcal/h | 12900Kcal/h | 17200Kcal/h | 25800Kcal/h | 344000Kcal/h | 51600Kcal/h | 77400Kcal/h | 103200Kcal/h | 154800Kcal/h | |
Circulation Pump Info | 6.6m³/h | 9m³/h | 15m³/h | 15m³/h | 25m³/h | 25m³/h | 25m³/h | 35m³/h | 35m³/h | 50m³/h |
2.5bar max | 2.5bar max | 2.5bar max | 2.5bar max | 2.5bar max | 2.5bar max | 2.5bar max | 2.5bar max | 2.5bar max | 2.5bar max | |
Inlet&outlet connection size | DN-25 PN-10 |
DN-25 PN-10 |
DN-32 PN-10 |
DN-32 PN-10 |
DN-40 PN-10 |
DN-40 PN-10 |
DN-40 PN-10 |
DN-50 PN-10 |
DN-50 PN-10 |
DN-65 PN-10 |
Cooling Water at 30 degree | 10m³/h | 14m³/h | 20m³/h | 25m³/h | 30m³/h | 35m³/h | 50m³/h | 70m³/h | 90m³/h | 120m³/h |
Cold Storage tank (optional) | 200L | 350L | 500L | 750L | 1000L | 1200L | 1500L | 2200L | 3000L | 4000L |
Expansion tank(standard) | 100L | 175L | 250L | 350L | 500L | 600L | 750L | 1000L | 1350L | 1800L |
Compressor | Dorin semi-closed compressor | Dorin compressor/HANBELL、Fusheng、Bitzer screw compressor | ||||||||
Operation Panel | 7-inch color touch screen display, temperature curve record | |||||||||
Control System | SIEMENS S7 PLC&Module,Set temperature difference of refrigeration on & off | |||||||||
Closed Circulation System | The whole system is a full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supplement oil automatically at low temperature | |||||||||
Circulation Pump | LNEYA Mangetic Pump/German Brand Mangetic Pump | |||||||||
Evaporator | Danfoss/KAORI plate heat exchanger | |||||||||
Condenser | Casing type water-cooled condenser / tube-type water-cooled condenser | |||||||||
Intermediate heat exchanger | Danfoss/KAORI plate heat exchanger | |||||||||
Refrigeration accessory | Oil separators, drying filters, expansion valves, refrigeration solenoid valves, pressure control, mirrors, etc. all use Emerson / Danfoss and other brands | |||||||||
Electric | AC contactors, intermediate relays, circuit breakers, thermal relays, etc. are Schneider / ABB brand | |||||||||
Refrigerant | R404A/R23 mixture,optional: R125/R23 mixture | |||||||||
Secondary refrigerant | No corrosive liquid, ethanol water, heat transfer oil etc. | |||||||||
Safety Protection | High pressure protect; water supply cut-off protection; over-current protection; leakage protection; sequential and phase failure protection; High temperature protection; Sensor Failure protection; Liquid low level protection etc. multi-safety protection | |||||||||
Level Indicator | Adopt glass liquid level indication | |||||||||
Piping material | Expansion tank, cold storage tank and circulation pipeline are all made of SUS304 | |||||||||
Case material | Channel steel + square tube + cold rolled plate sealing plate spray 7035 | |||||||||
Dimension cm | 100*150*185 | 205*145*205 | 205*145*205 | 205*145*175 | 245*145*205 | 300*160*225 | 350*160*205 | 400*160*225 | 500*200*225 | 650*200*225 |
Power | 14kW | 18kW | 26kW | 35kW | 52kW | 69kW | 104kW | 152kW | 200kW | 300kW |
dB | within 75dB | within 80 dB | within 90 dB | |||||||
Weight (kg) | 850 | 1000 | 1200 | 1450 | 2000 | 2400 | 3000 | 3600 | 4200 | 5600 |
Optional | Optional outside touch screen display controller (separated), the communication line distance is 10 meter | |||||||||
Optional | Optional explosion-proof touch screen control system (ExdeIIBT4), the communication line distance is 15 meter |
Contact : Tony Tony, 0510 82303782
Good deal: buying from seller
We invite you to read our terms of use. You can also visit our FAQ section and see our information section on the risks associated with counterfeiting.
This page is about importers and exporters of Low Temperature Chiller LN -60-10 Search in a category : Construction goods Search in a category : temperature, chiller |
Thursday, May 02, 2024
•Our organic olive groves and farmlands certify the environmentally friendly growing methods that fully respect natural cycle of crop and biodiversity. •The oil is made in our own milling/bottling installations, according to the local tradition handed down from our ancestors, combined...
OLEICOLA SAN FRANCISCO S.L.
- OliveoilSpain
- 23520 - Begijar
- +34 6 34 88 09 17
- +34 9 53 76 34 15
Wednesday, May 20, 2015
Quantity : 1000 - Price : N/A
HD4600 4 Ports HDMI Switch / 6 Ports Splitter Extender over CAT5e/6 It's the innovative and powerful solution for HDMI Extension. 4 HDMI sources are selectable and each of 6 RJ-45 ports cascade-chainable receiver which is capable of connecting another 2 receivers. The extended...
ACAFA Information Co.
- epanio
- 335 - Dasi Township
- +88 6 33 07 13 00
Sunday, July 08, 2012
Quantity : 1 - Price : negotiated
Mobile diving complex executed in double 20 ft marine containers with 60 m diver depth and diving station for operation of 2 working and 1 standing by divers. 1st container Diving complex: 20' marine container with additional door, illuminators and heat insulation, main switchboard...
MSCO
- 183038 - Murmansk
- +78 1 52 48 10 21
- +79 2 16 66 33 86