Everything else / Bulk

How to Prevent the HPLC Column Failure

The improper use of chromatographic columns will make the columns decrease or lose effectiveness.
Generally speaking, the columns always have problems at the end of them. If we can install a short column with the same stationary phase as the analysis column in front of analysis column, which is about five to thirty millimeter, the column will have a longer lifetime. Although the effectiveness with a short protective column is less, the final result is worthwhile.
The chromatographic columns' lifetime usually can reach two years and more when used correctly. One kind of the columns that are based on silica gel only can be used in pH values ranging from two to nine. Some adsorptive substances will be retained on the top of the column, especially some colored substances after used for a long time. For the new columns, the filler at the top of the columns may decrease and collapse, which reduce the column efficiency. And under this circumstance, the experimenters can restore the efficiency of the columns through adding fillers.
It is better to rinse the columns with eluent with strong eluting power after each work. When hydrochloric acid buffer solution is used as mobile phase, salt-free mobile phase is used to rinse. The compounds containing halogen family may corrode stainless . It is inappropriate to be exposed to them for a long time.The improper use of chromatographic columns will make the columns decrease or lose effectiveness.
Generally speaking, the columns always have problems at the end of them. If we can install a short column with the same stationary phase as the analysis column in front of analysis column, which is about five to thirty millimeter, the column will have a longer lifetime. Although the effectiveness with a short protective column is less, the final result is worthwhile.
The chromatographic columns' lifetime usually can reach two years and more when used correctly. One kind of the columns that are based on silica gel only can be used in pH values ranging from two to nine. Some adsorptive substances will be retained on the top of the column, especially some colored substances after used for a long time. For the new columns, the filler at the top of the columns may decrease and collapse, which reduce the column efficiency. And under this circumstance, the experimenters can restore the efficiency of the columns through adding fillers.
It is better to rinse the columns with eluent with strong eluting power after each work. When hydrochloric acid buffer solution is used as mobile phase, salt-free mobile phase is used to rinse. The compounds containing halogen family may corrode stainless . It is inappropriate to be exposed to them for a long time.

Location : Xi'an City , Shaanxi Province, P.R.China, 710077 Xi'an,
Contact : Bruce Lu, +86 29 89284429

Good deal: buying from seller

Visit our guide for a secure transaction! Under no circumstances Algomtl can be held responsible for the content of the ads published. Only the sellers and buyers responsability is involved in case of dispute.
We invite you to read our terms of use. You can also visit our FAQ section and see our information section on the risks associated with counterfeiting.
This page is about importers and exporters of
How to Prevent the HPLC Column Failure

Search in a category : Everything else / Bulk
Search in a category :
column, hplc, prevent, failure
France 59590 B2B Services
DIN BELLOWS GLOBE VALVE

Wednesday, September 14, 2016

Quantity : 5000 - Price : 50,00 €

Bellows Seal Stop Valves(Straight-Through Type) DIN Bellows Seal Stop Valve DIN Bellows Globe Valve DIN Faltenbalgventil Durchgangsform DIN Válvulas de fuelle DIN ventil uzavírací s vlnovcem přímý DIN Standard seteventil med belg (Rett løp modell) DIN Standardında Metal Körüklü...

ETM Armaturen

  • 59590 - Henri Durre
  • 86 577 67953935
Spain 28970 Equipment goods
Line Pellet, snack, nuts, grains, rinds, potato chips

Friday, December 13, 2024

Quantity : 1

The fryer model GP are automatic machines equipped with auxiliary belts are the best solution for the production of pellets. - Built in stainless steel sheet AISI 304 according to rules of machines and pellets Line, snack, nuts, grains, rinds, potatoes, chipsseguridadalimentaria...

Mafrigarlo

Turkey 84000 Vehicles
ALTERNATİVE JCB spare parts for JCB 3CX and JCB 4CX

Friday, December 15, 2017

OEM PART NO DESCRİPİTİON 66072 Crown Wheel and Pinion FOR CARRARO 13X30 66941 Crown Wheel and Pinion 15x37 2277448 CATERPİLLAR AİR FİLTER OUTER 2277449 CATERPİLLAR AİR FİLTER İNNER 01/117901 FAN BELT 01/124403 FAN BELT 01/124404 02/100073 Oil Filter Canister Type, MEDİUM MODEL 02/100284...

ANAC MAKINA CO LTD STI

  • 34800 - İSTANBUL
  • +905069691531
  • +9005069691531