DPM-6000 PM Monitor PM2.5/PM10
Quantity : 10,000 Price : 0-50,000
Overview Of DPM-6000 pm monitor Inhalable particle content is one of the most important indexes for measuring air quality. Combining years of experience in developing environment and safety monitoring instruments as well as the latest demand at home and abroad, our company has launched a new generation DPM-6000 atmospheric particulate monitor with high accuracy, reliability, stability and economy. Our pm monitor can measure PM10, PM2.5 and dust particles of other cut sizes, widely applied in inhalable particles concentration detection in environmental atmosphere monitoring.
Design of instrument meets US EPA and national standard
Adopt PM filter membrane enrichment technology
Particle cutter meets EPA standard TSP, PM10, PM2.5
Use simple, reliable mechanical transmission structure and modular design to ensure the measurement is accurate and reliable, and the pm monitor can operate stably for a long term.
PrincipleFeaturesSpecificationApplication
Principle Of DPM-6000 PM Monitor PM2.5/PM10
The monitoring principle of the pm monitor is mainly based on enrichment technology of atmospheric particulate and beta ray attenuation method. The pm 2.5 monitoring equipment concentrates on particulate matters whose aerodynamic equivalent diameter is smaller than 2.5/10μm on the rolled filter membrane. The air pollution analyzer adopts low-radiation 14C as a radioactive source. The emitted Beta-ray passes through the filter membrane with contaminants and will be received by the detector. The pm 2.5 measurement device is composed of a photo-multiplier tube (or Geiger detector), plastic scintillator and counter. The thickness of enrichment can be analyzed quantificationally according to Beta-ray energy that detector received, then the PM2.5/10 concentration in the air can be calculated.
Features Of DPM-6000 PM Monitor PM2.5/PM10
The design of the gas path keeps filter paper, a radioactive source and detector immovable during enrichment and measurement, ensuring a good lower detection limit.
US EPA standard beta ray attenuation method, which spares the complicated operations of TEOM, such as manually replace filter paper and weight. Compared to the light scattering method, our pm monitor has higher measurement accuracy.
Cutter, based on simulation verification of aerodynamics, will provide a various selection of accurate particle.
Sizes: PM1, PM2.5, PM10, TSP.
Sampling flow is measured by a mass flow sensor and corrected with collected ambient temperature and pressure to get the sampling flow of the field.
Use C14 source which is of low-density, low activity, and long half-life to realize stable measurement. No special protection for the pm measuring device is needed. Reliable and safe.
Flexible paper-pressing structure. Mechanical driving design of the pm 2.5 monitoring equipment is simple and reliable; greatly reduce paper breaking and paper jam and avoid the error caused by the moving of filter paper.
The pipeline heating system is used to eliminate interference from ambient humidity and make the detector fit into sudden.
Flow control system with precise closed-loop feedback; stable sampling flow and small error.
Various external ports, such as RS232/RS485, 4~20mA and etc.
Low maintenance frequency of the pm measuring device, once a year.
Specification Of DPM-6000 PM Monitor PM2.5/PM10
Measuring principle |
Beta ray attenuation method |
|
Performance Index |
Measuring Range |
0~1000μg/m3³or 0~10000μg/m3 (optional) |
Radioactive Source |
14C (carbon-14), radioactivity≤60μCi |
|
Accuracy |
≤5% |
|
Display Resolution |
1μg/m3 |
|
Lower Detection Limit |
5μg/m3 |
|
Flow Error |
≤±2% (generally set at 16.67L/min) |
|
Sampling Flow Stability |
≤±2% working point flow/24h |
|
Sampling Period |
≤1h (time is settable) |
|
Sampling Flow |
Default 16.67L/min |
|
Parallelism |
PM10≤10%, PM2.5≤15% |
|
Filter Paper Tape |
Filter Paper Tape |
Glass fiber, inner diameter: 40 mm, width:30 mm, service time 1 month (work period 1 h) |
Interface Para. |
I/O |
Rs232, RS485, 4-20mA, GPRS (optional) |
Data Storage |
One year |
|
Working Condition |
Cutting header |
Ambient temperature (-40~50)℃, ambient pressure (80~106kPa) |
Detector |
Ambient temperature (5-40)℃, ambient pressure (80-106kPa), humidity (≤90%) |
|
Power Supply |
AC (220±22)V, (50±1)Hz |
|
Dimension & Weight |
483×407×322(mm) (L×W×H); Monitor 30kg, Pump 8kg |
Application Of DPM-6000 PM Monitor PM2.5/PM10
Inhalable particle real-time monitoring in industry,, construction, residential district and etc.
Environment assessment, permission, and pollution forecast and pre-warning.
Ambient air quality monitoring and mobile air monitoring experimental station.
Occupational disease research, and long-term background environment research.
Secondary emission monitoring (coal storage area, wharf, etc.).
HANGZHOU ZETIAN TECHNOLOGY CO., LTD is a professional air pollution monitoring instruments manufacturers, we provide Water Quality Analyzers, Continuous Emission Monitoring & Process Control, Gas Analysis Modules, air quality monitor and etc. Want to know more? Please contact us.
Contact : Alex Wang, +0086 18957111635
Good deal: buying from seller
We invite you to read our terms of use. You can also visit our FAQ section and see our information section on the risks associated with counterfeiting.
This page is about importers and exporters of DPM-6000 PM Monitor PM2.5/PM10 Search in a category : Electronics / Computers Search in a category : monitor, pm10 |
Friday, April 24, 2015
Quantity : 10 Kg - Price : 180€
eirl NERA is a young company (import-export) trading and wholesale oils essential, food supplements (Spirulina ... ), spices, herbs, various products Organic agriculture mainly from Africa and Madagascar. NERA aims solidarity, fair working closely with producers promoting...
NERA
- 79200 - POMPAIRE
- 06 42 86 66 01
Wednesday, September 14, 2016
Quantity : 5000 - Price : 100,00 €
Bellows Seal Stop Valves (Angle Type) DIN Angle Type Bellows Sealed Stop Valve DIN Bellows Seal Globe Valve DIN Faltenbalgventil Eckform DIN Válvulas de fuelle(Paso angular.) DIN ventil uzavírací s vlnovcem rohový DIN Standard seteventil med belg (Vinkel modell) DIN Standardında...
ETM Armaturen
- 59590 - Henri Durre
- 86 577 67953935
Thursday, December 12, 2024
Applications : CMX-12 is a high definition digital AV Mixer, which is a simple type of HD/SD Video Mixer Editor to switch and effects. Each input BUS supports 6 inputs (2 x HDMI, 2 x Component, 2 x S-Video and Composite video) and also Background Color for special effect. The output...
Meicheng Audio Video Co., Ltd.
- meicheng
- 23511 - New Taipei City
- 886 2 82280311