CZ3000 Temperature Converter Signal Conditioner
Quantity : 1 million Price : 200-2000 CNY/pc
CZ3000 Temperature Signal Conditioner
Thermal resistance type signal isolators, the two-wire or three-wire system resistance signal is converted into 0/4~20mA current signal isolation or 0/1~5V voltage signal output. It is intelligent, can through the computer scope of heat resistance index number range and configuration.
This 5v to 24v signal converter should be supplied power independently. Input circuit, output circuit and power supply are each galvanically isolated.
Advantages of CZ3000 Temperature Converter Signal Conditioner
24V DC independent/ loop power supply
Line fault detection(LFD)
Configurable by software
Integral CJC on terminals/TC input terminals
Parameter of CZ3000 Temperature Converter Signal Conditioner
|
|
CZ3076 |
CZ3079 |
|
|
CZ3071 |
1/2 |
2/2 |
|
|
1/1 |
|
|
|
|
Input Signal |
Pt100,Cu100,Cu50 |
Pt100,Cu100,Cu50 |
Pt100,Cu100,Cu50 |
|
Output Current/Load Resistance |
0~20mA,4~20mA / RL ≤300Ω |
0~20mA,4~20mA / RL ≤300Ω |
0~20mA,4~20mA / RL ≤300Ω |
|
Output Voltage/Load Resistance |
0~5V,1~5V / RL ≥20kΩ |
0~5V,1~5V / RL ≥20kΩ |
0~5V,1~5V / RL ≥20kΩ |
|
Fault Current of Overrange/Underrange |
IH≈20.8mA/IL≈3.8mA |
IH≈20.8mA/IL≈3.8mA |
IH≈20.8mA/IL≈3.8mA |
|
Fault Current of Line Break |
I≈20.8mA |
I≈20.8mA |
I≈20.8mA |
|
Supply Voltage |
20~35V DC |
20~35V DC |
20~35V DC |
|
Power Reverse Protection |
Support |
Support |
Support |
|
Current Consumption(Supply voltage: 24V) |
≤35mA |
≤55mA |
≤55mA |
|
Temperature Drift |
0.01%F.S./℃ |
0.01%F.S./℃ |
0.01%F.S./℃ |
|
Response Time (0~90%) |
≤1s |
≤1s |
≤1s |
|
Dielectric Strength |
1500V AC;1min |
1500V AC;1min |
1500V AC;1min |
|
Insulation Resistance |
≥100MΩ; 500V DC |
≥100MΩ; 500V DC |
≥100MΩ; 500V DC |
|
EMC Standards |
GB/T 18268(IEC 61326-1) |
GB/T 18268(IEC 61326-1) |
GB/T 18268(IEC 61326-1) |
|
Ambient Temperature |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
|
Suitable Field Apparatus |
2-or 3-wire RTD |
2-or 3-wire RTD |
2-or 3-wire RTD |
|
|
|
|
|
|
|
CZ3072 |
CZ3074 |
CZ3079.TC |
|
1/1 |
1/2 |
2/2 |
|
|
Input Signal(Customized mV signal) |
T、E、J、K、N、R、S、B |
T、E、J、K、N、R、S、B |
T、E、J、K、N、R、S、B |
|
Internal CJC Temperature Range |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
|
CJC Precision |
±1℃ |
±1℃ |
±1℃ |
|
Output Current/Load Resistance |
0~20mA,4~20mA / RL≤300Ω |
0~20mA,4~20mA / RL≤300Ω |
0~20mA,4~20mA / RL≤300Ω |
|
Output Voltage/Load Resistance |
0~5V,1~5V / RL ≥20kΩ |
0~5V,1~5V / RL ≥20kΩ |
0~5V,1~5V / RL ≥20kΩ |
|
Fault Current of Overrange/Underrange |
IH≈20.8mA/IL ≈3.8mA |
IH≈20.8mA/IL ≈3.8mA |
IH≈20.8mA/IL ≈3.8mA |
|
Fault Current of Line Break |
I≈20.8mA |
I≈20.8mA |
I≈20.8mA |
|
Supply Voltage |
20~35V DC |
20~35V DC |
20~35V DC |
|
Power Reverse Protection |
Support |
Support |
Support |
|
Current Consumption(Supply voltage: 24V) |
≤35mA |
≤55mA |
≤55mA |
|
Temperature Drift |
0.01%F.S./℃ |
0.01%F.S./℃ |
0.01%F.S./℃ |
|
Response Time (0~90%) |
≤1s |
≤1s |
≤1s |
|
Dielectric Strength |
1500V AC;1min |
1500V AC;1min |
1500V AC;1min |
|
Insulation Resistance |
≥100MΩ; 500V DC |
≥100MΩ; 500V DC |
≥100MΩ; 500V DC |
|
EMC Standards |
GB/T 18268(IEC 61326-1) |
GB/T 18268(IEC 61326-1) |
GB/T 18268(IEC 61326-1) |
|
Ambient Temperature |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
|
Suitable Field Apparatus |
TC and mV signal sensor |
TC and mV signal sensor |
TC and mV signal sensor |
|
|
|
|
|
|
|
1/1:CZ3077 |
1/1:CZ3177 |
1/1:CZ3277 |
|
2/2:CZ3078 |
2/2:CZ3178 |
2/2:CZ3278 |
|
|
Input Signal |
Pt100,Cu100,Cu50 |
T、E、J、K、N、R、S、B |
Pt100,Cu100,Cu50 |
|
(Customized mV signal) |
T、E、J、K、N、R、S、B |
||
|
Internal CJC Temperature Range |
|
-20~+60℃ |
-20~+60℃ |
|
CJC Precision |
|
±1℃ |
±1℃ |
|
Output Current |
4~20mA |
4~20mA |
4~20mA |
|
Load Resistance |
RL ≤(Ue -12)/0.021Ω |
RL ≤(Ue -12)/0.021Ω |
RL ≤(Ue -12)/0.021Ω |
|
Fault Current of Overrange/Underrange |
IL ≈20.8mA/IL ≈3.8mA |
IL ≈20.8mA/IL ≈3.8mA |
IL ≈20.8mA/IL ≈3.8mA |
|
Fault Current of Line Break |
I≈20.8mA |
I≈20.8mA |
I≈20.8mA |
|
Loop Supply Voltage(Ue) |
12~30V DC |
12~30V DC |
12~30V DC |
|
Power Reverse Protection |
Support |
Support |
Support |
|
Temperature Drift |
0.01%F.S./℃ |
0.01%F.S./℃ |
0.01%F.S./℃ |
|
Response Time (0~90%) |
≤1s |
≤1s |
≤1s |
|
Dielectric Strength |
1500V AC;1min |
1500V AC;1min |
1500V AC;1min |
|
Insulation Resistance |
≥100MΩ; 500V DC |
≥100MΩ; 500V DC |
≥100MΩ; 500V DC |
|
EMC Standards |
GB/T 18268(IEC 61326-1) |
GB/T 18268(IEC 61326-1) |
GB/T 18268(IEC 61326-1) |
|
Ambient Temperature |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
|
Suitable Field Apparatus |
2-or 3-wire RTD |
TC sensor,mV signal |
RTD,TC sensor |
Signal conditioners are electrical devices, which are connected between the industrial field instrument and the control room. CHENZHU's signal conditioner complete in specifications.
Contact : Danping Li, 021 6451 3350
Good deal: buying from seller
We invite you to read our terms of use. You can also visit our FAQ section and see our information section on the risks associated with counterfeiting.
|
This page is about importers and exporters of CZ3000 Temperature Converter Signal Conditioner Search in a category : Equipment goods Search in a category : conditioner, converter, signal, cz3000, temperature |
Tuesday, June 16, 2015
Quantity : 100 roll
JC-Paper Series Refractory ceramic fiber paper sealing gasket Product Features Easy to cut,wrap or form Low thermal conductivity and heat storage Excellent thermal shock and flame resistance Light weight Resilient Excellent hydrophobic property Good dielectric strength Free...
Zibo JC Eco-Tech Co., Ltd
- 255086 - China
- +86 15505335058
- +86 533 3593322
Monday, March 31, 2014
Quantity : ≥200KG - Price : 5.88 USD/KG~6.98 USD
RTV-2 silicone rubber for Mold making Product Model: INNO SILICA® IS-CR Hardness: 15 Shore A, 20 Shore A, 25 Shore A, 30 Shore A, 35 Shore A, 40 Shore A Applications: It is used primarily in the mold-making industry with pouring or brushing onto the models to make the molds. RTV-2...
Shen Zhen Inno Silica Co.,Ltd
- innosilica
- 518057 - Shenzhen
- +86 15768639143
Sunday, May 29, 2016
Quantity : 200 - Price : 7,15 €
- Avantages des luminaires LED OSRAM - - Qualité OSRAM - Produits LED de haute qualité pour les demandes exigeantes - Remplacement direct des luminaires conventionnels fluorescents ou halogènes - Le remplacement des luminaires standard permet jusqu'à 85 % d'économie d'énergie...