Equipment goods
CZ3000 Temperature Converter Signal Conditioner |
|
|
CZ3076 |
CZ3079 |
|
|
CZ3071 |
1/2 |
2/2 |
|
|
1/1 |
|
|
|
|
Input Signal |
Pt100,Cu100,Cu50 |
Pt100,Cu100,Cu50 |
Pt100,Cu100,Cu50 |
|
Output Current/Load Resistance |
0~20mA,4~20mA / RL ≤300Ω |
0~20mA,4~20mA / RL ≤300Ω |
0~20mA,4~20mA / RL ≤300Ω |
|
Output Voltage/Load Resistance |
0~5V,1~5V / RL ≥20kΩ |
0~5V,1~5V / RL ≥20kΩ |
0~5V,1~5V / RL ≥20kΩ |
|
Fault Current of Overrange/Underrange |
IH≈20.8mA/IL≈3.8mA |
IH≈20.8mA/IL≈3.8mA |
IH≈20.8mA/IL≈3.8mA |
|
Fault Current of Line Break |
I≈20.8mA |
I≈20.8mA |
I≈20.8mA |
|
Supply Voltage |
20~35V DC |
20~35V DC |
20~35V DC |
|
Power Reverse Protection |
Support |
Support |
Support |
|
Current Consumption(Supply voltage: 24V) |
≤35mA |
≤55mA |
≤55mA |
|
Temperature Drift |
0.01%F.S./℃ |
0.01%F.S./℃ |
0.01%F.S./℃ |
|
Response Time (0~90%) |
≤1s |
≤1s |
≤1s |
|
Dielectric Strength |
1500V AC;1min |
1500V AC;1min |
1500V AC;1min |
|
Insulation Resistance |
≥100MΩ; 500V DC |
≥100MΩ; 500V DC |
≥100MΩ; 500V DC |
|
EMC Standards |
GB/T 18268(IEC 61326-1) |
GB/T 18268(IEC 61326-1) |
GB/T 18268(IEC 61326-1) |
|
Ambient Temperature |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
|
Suitable Field Apparatus |
2-or 3-wire RTD |
2-or 3-wire RTD |
2-or 3-wire RTD |
|
|
|
|
|
|
|
CZ3072 |
CZ3074 |
CZ3079.TC |
|
1/1 |
1/2 |
2/2 |
|
|
Input Signal(Customized mV signal) |
T、E、J、K、N、R、S、B |
T、E、J、K、N、R、S、B |
T、E、J、K、N、R、S、B |
|
Internal CJC Temperature Range |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
|
CJC Precision |
±1℃ |
±1℃ |
±1℃ |
|
Output Current/Load Resistance |
0~20mA,4~20mA / RL≤300Ω |
0~20mA,4~20mA / RL≤300Ω |
0~20mA,4~20mA / RL≤300Ω |
|
Output Voltage/Load Resistance |
0~5V,1~5V / RL ≥20kΩ |
0~5V,1~5V / RL ≥20kΩ |
0~5V,1~5V / RL ≥20kΩ |
|
Fault Current of Overrange/Underrange |
IH≈20.8mA/IL ≈3.8mA |
IH≈20.8mA/IL ≈3.8mA |
IH≈20.8mA/IL ≈3.8mA |
|
Fault Current of Line Break |
I≈20.8mA |
I≈20.8mA |
I≈20.8mA |
|
Supply Voltage |
20~35V DC |
20~35V DC |
20~35V DC |
|
Power Reverse Protection |
Support |
Support |
Support |
|
Current Consumption(Supply voltage: 24V) |
≤35mA |
≤55mA |
≤55mA |
|
Temperature Drift |
0.01%F.S./℃ |
0.01%F.S./℃ |
0.01%F.S./℃ |
|
Response Time (0~90%) |
≤1s |
≤1s |
≤1s |
|
Dielectric Strength |
1500V AC;1min |
1500V AC;1min |
1500V AC;1min |
|
Insulation Resistance |
≥100MΩ; 500V DC |
≥100MΩ; 500V DC |
≥100MΩ; 500V DC |
|
EMC Standards |
GB/T 18268(IEC 61326-1) |
GB/T 18268(IEC 61326-1) |
GB/T 18268(IEC 61326-1) |
|
Ambient Temperature |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
|
Suitable Field Apparatus |
TC and mV signal sensor |
TC and mV signal sensor |
TC and mV signal sensor |
|
|
|
|
|
|
|
1/1:CZ3077 |
1/1:CZ3177 |
1/1:CZ3277 |
|
2/2:CZ3078 |
2/2:CZ3178 |
2/2:CZ3278 |
|
|
Input Signal |
Pt100,Cu100,Cu50 |
T、E、J、K、N、R、S、B |
Pt100,Cu100,Cu50 |
|
(Customized mV signal) |
T、E、J、K、N、R、S、B |
||
|
Internal CJC Temperature Range |
|
-20~+60℃ |
-20~+60℃ |
|
CJC Precision |
|
±1℃ |
±1℃ |
|
Output Current |
4~20mA |
4~20mA |
4~20mA |
|
Load Resistance |
RL ≤(Ue -12)/0.021Ω |
RL ≤(Ue -12)/0.021Ω |
RL ≤(Ue -12)/0.021Ω |
|
Fault Current of Overrange/Underrange |
IL ≈20.8mA/IL ≈3.8mA |
IL ≈20.8mA/IL ≈3.8mA |
IL ≈20.8mA/IL ≈3.8mA |
|
Fault Current of Line Break |
I≈20.8mA |
I≈20.8mA |
I≈20.8mA |
|
Loop Supply Voltage(Ue) |
12~30V DC |
12~30V DC |
12~30V DC |
|
Power Reverse Protection |
Support |
Support |
Support |
|
Temperature Drift |
0.01%F.S./℃ |
0.01%F.S./℃ |
0.01%F.S./℃ |
|
Response Time (0~90%) |
≤1s |
≤1s |
≤1s |
|
Dielectric Strength |
1500V AC;1min |
1500V AC;1min |
1500V AC;1min |
|
Insulation Resistance |
≥100MΩ; 500V DC |
≥100MΩ; 500V DC |
≥100MΩ; 500V DC |
|
EMC Standards |
GB/T 18268(IEC 61326-1) |
GB/T 18268(IEC 61326-1) |
GB/T 18268(IEC 61326-1) |
|
Ambient Temperature |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
|
Suitable Field Apparatus |
2-or 3-wire RTD |
TC sensor,mV signal |
RTD,TC sensor |
Signal conditioners are electrical devices, which are connected between the industrial field instrument and the control room. CHENZHU's signal conditioner complete in specifications.
Good deal: buying from seller
|
This page is about importers and exporters of CZ3000 Temperature Converter Signal Conditioner Search in a category : Equipment goods Search in a category : temperature, conditioner, signal, converter, cz3000 |
Monday, May 23, 2016
Quantity : 100000 met - Price : 0.280usd
Thomsun Industries LLC is a professional PPR manufacturers and ppr suppliers in Dubai UAE. T-Mech pressure piping system is considered to be the best carrier of potable water, using the revolutionary raw material of PPR-80 of Borouge brand. T-Mech PPR major products range covers...
Thursday, May 30, 2013
Quantity : 1000000 to - Price : 10€
Material "Enola" - a unique and unparalleled experience in the world; Building material made of expanded polystyrene, cement and special additives, the expertise of our company. Representatives of several foreign countries are increasingly interested in this technology and we are...
Sunday, May 29, 2016
Quantity : 200 - Price : 6,35 €
- Avantages des luminaires LED OSRAM - - Qualité OSRAM - Produits LED de haute qualité pour les demandes exigeantes - Remplacement direct des luminaires conventionnels fluorescents ou halogènes - Le remplacement des luminaires standard permet jusqu'à 85 % d'économie d'énergie...