Women clothing

Cross Flow Cooling Tower

Cross flow cooling tower is an induced draft cross flow cooling tower that can cool water. The water flows vertically from the top of the tower, and the air flows horizontally through the filler. The air flow is orthogonal to the water flow in the cooling tower.

The cross flow type cooling tower is often used in residential areas with strict noise requirements, and it is a cooling circulating tower used more frequently in the air conditioning industry.

Cross Flow and Counter Flow Cooling Tower

Technical Comparison Between Counter Flow Cooling Tower And Cross flow Cooling Tower

Project Counter Flow Cooling Tower Cross Flow Cooling Tower

Tower Height Due to the height of the air inlet and the horizontal arrangement of the water eliminator,the total height of the counter flow tower is high and the volume is large. Because the height of packing is close to the tower height and the water

eliminator does not occupy the height, the total height of cross flow tower is low and the volume is small.

Water Distribution System The counter flow tower adopts the nozzle to distribute water, which has higher requirements on the pressure head and the nozzle is easy to be blocked. The cross flow tower adopts the water distribution system of gravity falling naturally, so the water dispersion hole is not easy to be blocked, and the water distribution is uniform, which improves the packing performance to the maximum.

Overhaul The whole body of counter flow tower is a closed structure, so it should be shut down during equipment maintenance or routine maintenance. The cross flow tower body is equipped with an access door, and there is room for maintenance inside the tower, so that the equipment can be overhauled and maintained without shutdown.

Wind Resistance Due to the reverse flow of water and gas in the counter flow tower and the obstruction of water distribution to the air flow, the wind resistance is high and the power consumption of the motor is large. The cross flow tower is lower than the counter flow tower, and the high air inlet means the high packing, so the air inlet speed is low and the motor power consumption is low.

Noise There is a large distance between the packing of counter flow tower and the lower water tank. After the water falls from the packing, there is a loud noise. A small part of the lower part of the packing of the cross flow tower is submerged in the water, so that the water flows directly into the lower water tank after passing through the packing surface, and the noise is very low.

Water Loss Because the fan of counter flow tower is located directly above the packing and the distance is close, the water drift is large. In addition, the splash loss of the water in the lower tank is very large, and it is easy to form water mist around the cooling tower, which is easy to cause the reproduction of Legionella. The cross flow tower fan is located in the center of the cooling tower, and the packing is located on both sides, so the water drift is very small, which is an environmental protection product.

Modularization The unit of counter flow tower is

supplied with air from all sides, and the air inlet surface is reduced after module combination, which affects the air inlet volume.The power consumption of the motor will increase. The cross flow tower is specially designed for modularization,

with air inlet from both sides of the unit. After the combination of the modules, the air inlet has no change, and the power consumption of the motor remains unchanged.

Characteristics of Cross Flow Type Cooling Tower

lEnergy-saving, low water pressure, small wind resistance, low-speed motor, no dripping noise and wind noise, and convenient maintenance of filler and water distribution system

lAccording to the shape of the building, the foundation can be built randomly, and multiple cell cooling towers can be started according to the water temperature required.

Advantages of Cross Flow Cooling Tower

lAs a major crossflow and counterflow cooling tower inc, our cross flow induced draft cooling tower casing is made by machine. It makes the casing have a smooth surface and good quantity.

  1. The motor driver we using belt reducer with low noise characteristic. The belt is very stronger, clients no need to replace it frequently. If you choose a cross-flow closed circular cooling tower, we will use a cooling tower direct drive motor.

  1. The fresh air comes from the cross flow cooling tower working tow side continuous, the fresh air will take water heat continuously.

Our cooling tower company provides cooling tower filling, drift eliminator, fan, motor, gearbox, belt reducer, spray nozzle, sprinkler head, float ball, air inlet louvers, etc... Whatever cooling tower parts you need, you will find them in our cooling towers LLC AUVC.

If you want to know more information, such as cross flow cooling tower design, cross flow cooling tower pdf, cross flow cooling tower diagram, etc, you can click our official website.

Location : Lingjiang Village,Dongguan Street,Shangyu District,Shaoxi ng City, Zhejiang Province,China, 312300 Shaoxing,
Contact : AUVC ctauvc, 057582331987

Good deal: buying from seller

Visit our guide for a secure transaction! Under no circumstances Algomtl can be held responsible for the content of the ads published. Only the sellers and buyers responsability is involved in case of dispute.
We invite you to read our terms of use. You can also visit our FAQ section and see our information section on the risks associated with counterfeiting.
This page is about importers and exporters of
Cross Flow Cooling Tower

Search in a category : Women clothing
Search in a category :
tower, flow, cooling, cross
Indonesia 1440 Equipment goods
Dimatix Sapphire QS-256/10 AAA Printhead

Wednesday, June 17, 2015

Quantity : 100 - Price : $2,050.00

- Dimatix Sapphire QS-256/10 AAA Printhead - The Performa™ Sapphire QS-256/10 AAA printhead delivers best-in-class jetting accuracy combined with versatile grayscale operation. Its lightweight, thin-profile design and configurability plus support for a broad range of ink formulations...

PT DIGITAL MEDIA PRINTER

DELTA PARTNER'S : Sandal thinness     THE CELLULETTE is the 1°

Sunday, September 02, 2007

THE CELLULETTE is the 1° sandal thinness with tests of effectiveness carried out by an approved French laboratory, proving a significant thinning in 28 days of use. Proven slimming and anti cellulite effectiveness The sole of CELLULETTE slope backwards at an angle 8 degrees and the...

deltapartners

  • issy
  • 92600 - ASNIERES SUR SEINE
  • +33 1 41 11 34 34
France 59590 B2B Services
DIN Long life-Heavy Duty Bellows Seal Stop Valves

Wednesday, September 14, 2016

Quantity : 5000 - Price : 50,00 €

Long life-Heavy Duty Bellows Seal Stop Valves DIN Standard Long Life-Heavy Duty Bellows Sealed Stop Valves DIN Long life bellows Seal Stop Valve DIN Long life bellows globe valve DIN Long bonnet bellows globe valve DIN Faltenbalgventil lange Bauform DIN Válvulas de fuelle de...

ETM Armaturen

  • 59590 - Henri Durre
  • 86 577 67953935