Common Mistakes in Pipette Operation

In laboratories where the pipe ttes are used frequently, it is often heard that the sound of tapping the tips is one after another, adding a bit of music to the boring laboratory life.

When you look into it, the user is afraid that the tip can't be tightened. After the tip is attached to the pipette, tap it again in the tip box several times. It is hoped that the impact of the pipetting is ensured by such an impact force. Where is this operation wrong?

1. Under the action of impact, the pipette tip may be deformed to affect the precision of pipetting;
2. The part of the pipette sleeve that contacts the tip passes through a number of strong frictions, which gradually becomes rough and it is difficult to ensure the sealing property, and in order to achieve a good sealing property, a larger impact force is required, and the vicious cycle starts;
3. The small-scale pipette has a relatively small handle, which is likely to become a fishing hook under the continual impact of the impact;
4. Sometimes this impact is greater than the force that the pipette falls on the ground, and some of the precision parts in the pipette are at risk of being overwhelmed and strike.

Hawach Single-Channel Manual Pipette

Advanced Fully Autoclave 812 Channels Adjustable Pipettes

Hawach Electronic Control Digital Pipette

Location : Xi'an City , Shaanxi Province, P.R.China, 710077 Xi'an,
Contact : Bruce Lu, +86 29 89284429

Good deal: buying from seller

Visit our guide for a secure transaction! Under no circumstances Algomtl can be held responsible for the content of the ads published. Only the sellers and buyers responsability is involved in case of dispute.
We invite you to read our terms of use. You can also visit our FAQ section and see our information section on the risks associated with counterfeiting.
This page is about importers and exporters of
Common Mistakes in Pipette Operation

Search in a category : Everything else / Bulk
Search in a category :
pipette, common, mistakes, operation
France 26250 B2B Services
Factory Inspections, Factory Audits in China

Tuesday, September 01, 2026

Quantity : 30 - Price : 328 USD

Complete Factory Audits / Factory Inspections The aim of a factory audit is to confirm that your factory has the production capacity, capability and quality to meet your production needs. Our highly qualified auditors inspect the factory thorough fully. They carry out a comprehensive...

Web Commerce Worldwide

Hong Kong 518102 Medical
CPU Temperature Monitor With LCD For Computer Case

Tuesday, September 01, 2026

♦ Functions * 2-channel temperature monitor * 1-channel fan speed control * Run time function * Fan fault alarm * Temperature fault alarm * Fan speed storage function * Auto fan speed control → 40°C: Low 50°C: Middle 60°C: High * Immediate visual indication of Fan/HDD...

Tengda Electronics Limited

  • simeongao
  • 518102 - hongkong
  • +85 2 21 10 18 65
Hong Kong 999077 Equipment goods
APIwellhead

Saturday, June 29, 2013

Quantity : 1 - Price : USD2310

Wellhead Function: During drilling operation, casing head is an important equipment for controlling wellhead pressure. Raw Material: Carbon steel or low alloy steel comply with API Spec.6A. Applied Casing Program: 20"×13-3/8"×9-5/8"× 7"×5-1/2", or as user's requirements. Bottom Connection...

Kergy Oilfield Equipment Co.,LTD

  • kergy
  • 999077 - HongKong
  • 86 15399023516