The Operation Steps of Syringe Filter
Preparations of Syringe Filter
(1)After the filter core and shell are thoroughly cleaned and sterilized, the filter is installed.
(2) After the installation of the Syringe Filter, the whole filtration system must be thoroughly flushed with clean water.
(3) After the whole filtration system is washed out, the filtration operation can be carried out.
Filtration and cleaning operation in production process
Open the exhaust valve, and slowly open the feed valve, introduce the material to be filtered. When the material flow out of the outlet of the exhaust valve, immediately close the exhaust valve, and slowly open the discharge valve.
In the initial stage of filtration, because the Syringe Filter element is still very clean and the filtering speed is very fast, the pressure in the filter is generally maintained at 0.05-1 Mpa. With the passage of time, the pressure in the filter can be gradually increased in order to maintain proper filtration rate. However, the maximum pressure in the filter cannot exceed the maximum operating pressure allowed by the filter element of different materials.
When the pressure in the Syringe Filter is higher and the filtration speed is slower, the filter operation should be stopped and the filter cleaned.
Backwash of Syringe Filter element
(1) For the fine filtration of mineral water and water treatment, clean water can be used for backwashing first, and then clean water filtered by terminal can be used for backwashing.
(2) For the filtration of fermentation broth and sugary broth such as and beverage, it is suggested that the clean oil-free compressed air should be used to blow back, then the clean water should be used to flush back, and then the filtered clean water should be used to flush back.
(3) When the filter element has been used for a long time and the filtering speed still does not recover satisfactorily after using the method mentioned above, the filter element can be discharged and immersed in NaOH solution of 2-4% concentration for 4-8 hours, then rinsed with clean water filtered by the terminal to the non-residual alkali solution, and then loaded into the filter to continue to use.
(4) For the users who are not three-shift continuous production, it is suggested that the filters should be washed before each shift leaves work, so as to avoid the long-term adhesion of dirt and bacteria clustering, which will affect the normal operation of the next shift.
Contact : Bruce Lu, +86 29 89284429
Good deal: buying from seller
We invite you to read our terms of use. You can also visit our FAQ section and see our information section on the risks associated with counterfeiting.
This page is about importers and exporters of The Operation Steps of Syringe Filter Search in a category : Everything else / Bulk Search in a category : steps, operation, syringe, filter |
Sunday, November 10, 2024
We are the leading providers of Energy drinks like Red Bull, shark, charger and many others.We can also supply drinks like Pepsi, Coca Cola, Fanta, Sprite and other products.We also provide better quality mineral water. We present our product list. Red Bull Monster Assault Rockstar...
Vente en Gros
- 40400 - Kuala Lumpur
- +60 1 46 26 71 59
- +60 1 42 85 90 62
Thursday, August 01, 2013
Quantity : moq:1pcs - Price : USD154.6
The black JVC GZ-E100 Full HD Everio Camcorder shoots Full HD 1920 x 1080 video. It features an SD/SDHC/SDXC memory card slot, back-illuminated 1/5.8" 2.5-megapixel CMOS image sensor and Konica Minolta HD lens. The high-quality HD lens supports 40x optical zoom, 70x Dynamic Zoom...
AC Electronic Ltd
- 999077 - HongKong
- +85 2 23 25 18 67
- +86 13501567844
Thursday, November 14, 2024
DSS-R-CL1100 Pro Streaming Recorder & Automatic Learning System, it can perform the digital learning environment with applications of digital media. Simplify digital teaching and learning software and hardware environment, it provides "Network assisted instruction", "Video assisted...
Meicheng Audio Video Co., Ltd.
- meicheng
- 23511 - New Taipei City
- 886 2 82280311