Everything else / Bulk

Several Attentions about Using and Maintaining Chromatographic Columns

It is important for the experimenters to use and maintain chromatographic columns correctly. They should focus on many some things so as to protect the columns in the using process. Here we talk about several attentions.

Avoid changing pressure and temperature dramatically and any mechanical vibration. Sudden changes in temperature affect the filling conditions in the columns. And sudden changes of column pressure may loosen the fillers. Consequently, people should adjust the flow rate of the fillers slowly to protect the fillers.

Change the composition of the solvents gradually. The experimenters should change the composition of the solvents gradually, especially in the reversed-phase chromatography.

Do not backwash the columns. Generally speaking, chromatographic columns cannot be back washed. But, if the manufacturer specifies the columns can be back washed, the experimenters can remove the impurities through backwashing.

Choose a suitable mobile phase. The suitable mobile phase is chosen to avoid the destruction of the stationary phase. Sometimes it is a better way to install a pre-column which has the same substrate and little impact on the reaction, where the mobile phase will be pre-reacted before entering the analysis column.

Location : Xi'an City , Shaanxi Province, P.R.China, 710077 Xi'an,
Contact : Bruce Lu, +86 29 89284429

Good deal: buying from seller

Visit our guide for a secure transaction! Under no circumstances Algomtl can be held responsible for the content of the ads published. Only the sellers and buyers responsability is involved in case of dispute.
We invite you to read our terms of use. You can also visit our FAQ section and see our information section on the risks associated with counterfeiting.
This page is about importers and exporters of
Several Attentions about Using and Maintaining Chromatographic Columns

Search in a category : Everything else / Bulk
Search in a category :
columns, chromatographic, attentions, maintaining
Russia 183038 B2B Services
Mobile diving complex

Sunday, July 08, 2012

Quantity : 1 - Price : negotiated

Mobile diving complex executed in double 20 ft marine containers with 60 m diver depth and diving station for operation of 2 working and 1 standing by divers. 1st container Diving complex: 20' marine container with additional door, illuminators and heat insulation, main switchboard...

MSCO

  • 183038 - Murmansk
  • +78 1 52 48 10 21
  • +79 2 16 66 33 86
France 450006 Raw materials
White aluminum for refractory material 1-3mm

Friday, June 21, 2013

Quantity : 2000T/mont - Price : 880usd

Description: white aluminum, a kind of high-grade refractories, was made from the high quality alumina by melting above 2000 in the electric arc furnace and cooling. It is white with the main crystal phase alpha-Al2O3. The white alumina produced in titling electric arc furnace has...

Henan Sicheng Co, ltd

  • 450006 - Henan province
  • 0086 371 68706009
  • 8615890630517
Taiwan 334 Equipment goods
Horizontal Round Bottle Labeling Machine LR460

Friday, November 08, 2024

Quantity : 30 - Price : depend on situation

- Horizontal Round Bottle Labeling Machine - Model No.: LR-460 Horizontal Round Bottle Labeling Machine LR-460 is available for cylindrical containers and products labeling that are not vertically stable (Round Bottom or Top-Heavy) including ampoules,crayons,batteries,lip balm containers...

Autopack Co.,Ltd