PSS-Miss 5.5 Minimally Invasive Spine System
PSS-Miss 5.5 Minimally Invasive Spine System
▶▶ Specification
|
Implants |
Diameter (mm) |
Length (mm) |
|
Polyaxial Screw |
Φ5.5-φ7.0 (0.5 increase) |
30-55 (5 increase) |
|
Single-axis Screw |
Φ5.5-φ7.0 (0.5 increase) |
30-55 (5 increase) |
|
Rod (Straigh) |
Φ5.5 |
30-120 |
|
Rod (Curved) |
Φ5.5 |
30-120 |
▶▶ Product Details
Integrated long tail nail design
More stable than extended casing
Convenient to plant sticks and tighten the top wire
Half-way double thread
Fixed stronger
Faster nail placement
Suitable for different bone types
Tail design
The tail can be broken off at the end the long tail
Prevent long tail deformation
Negative angle reverse thread
Reduce lateral stress
Increase vertical pressure and holding power
Thread start Blunt design
Can prevent wrong threading
Easy implantation process
Curved titanium rod
Pre-defined physiological curve
Reduce intraoperative bending
Single-axis Screw
Nail base can be rotated 360
Easy to penetrate the rod
Polyaxial Screw
Greater range of motion
Reduce nail head collision
More flexible structural installation
▶▶ Medical Tips
What is minimally invasive pedicle screws?
Unlike traditional spinal surgery, which requires incisions up and down the middle of the back and muscle retraction, a minimally invasive procedure uses tiny cameras and smaller skin incisions. Surgeons are able to work precisely in smaller surgical fields.
Indications
Herniated disc.
Spinal stenosis (narrowing of the spinal canal)
Spinal deformities (like scoliosis)
Spinal instability.
Spondylolysis (a defect in a part of lower vertebrae)
Fractured vertebra.
Removal of a tumor in the spine.
Infection in the spine.
Benefit
Minimally invasive spine surgery uses small incisions, compared to large openings on the back and neck. As a result, the risk of infection is drastically reduced and blood loss is minor. Also, with limited intrusion there is little to no muscle damage that occurs.
Causes of Fractures
Spinal fractures may occur due to a variety of factors. The most common cause is related to trauma such as high velocity car accidents, fall from height, or high impact sports. Other causes may include pathologic fractures related to osteoporosis or cancer.
Contact : inature Tao, +86 13358048801
Good deal: buying from seller
We invite you to read our terms of use. You can also visit our FAQ section and see our information section on the risks associated with counterfeiting.
|
This page is about importers and exporters of PSS-Miss 5.5 Minimally Invasive Spine System Search in a category : Medical Search in a category : invasive, spine, minimally, system |
Tuesday, December 02, 2025
Unitronics Samba – Automate Control Engineering Ltd. (winston@automate-ace.com) Still using text display? it's SAMBA time! Improve your competitive advantage. Great look - incredible price. System integrators and OEMs often develop applications that require PLC control, but that...
Automate Control Engineering Ltd.
- automatehk
- 999077 - Hong Kong
- +85 2 23 42 72 76
Sunday, February 26, 2017
Quantity : 500 - Price : 12,00 €
♦ Functions * 1-channel temperature monitor * 2-channel fan speed control * 4-level fan speed control (manual) * Fan speed storage function * Immediate visual indication of Fan operation ♦ Buttons * POWER: Turn off the system power * UP: Increases fan speed ( level 1–...)
Tengda Electronics Limited
- simeongao
- 518102 - hongkong
- +85 2 21 10 18 65
Tuesday, November 25, 2025
Quantity : 1
The fryer model GP are automatic machines equipped with auxiliary belts are the best solution for the production of pellets. - Built in stainless steel sheet AISI 304 according to rules of machines and pellets Line, snack, nuts, grains, rinds, potatoes, chipsseguridadalimentaria...
Mafrigarlo
- mafrigarlo
- 28970 - humanes de madrid
- 91 6971596





