Manifold Absolute Pressure Sensor
Description
H -Series PRESSURE SENSOR is a ssop-hybrid device including a piezoresistive pressure sensor and a signal conditioning circuit. The H-series Pressure sensor has the features of the small form factor, high reliability and high accuracy. This temperature compensated and calibrated sensor provides an accurate, high level analog output signal that is proportional to applied pressure. The pressure rang of the sensor cell is 20~250 kPa absolute pressure. The supply voltage is 5±0.5V,the type supply current is 2.0mA.
H -Series PRESSURE SENSOR can customize the characteristics design according to the requirements of the costumer.
Features
l 2.5% Maximum Error Over 0° to 85°C
l Temperature Compensated Over 40°C to +125°C
l Small size
l High reliability, low drift
APPLICATIONS
l Automotive Pressure Monitoring
l Pneumatic Gages
l Hand-held Meters
| Characteristic | Symbol | Min | Typ | Max | Unit | |
| Pressure Range | Pop | 20 | --- | 250 | kPa | |
| Supply Voltage(1) | VS | 4.5 | 5.0 | 5.5 | Vdc | |
| Supply Current | IO | --- | 2 | 4 | mAdc | |
| Minimum Pressure Offset @ VS = 5.0 Volts(3) (0 to 85°C)(2) | VOff | 0.355 | 0.400 | 0.445 | Vdc | |
| Full Scale Output @ VS = 5.0 Volts(3) (0 to 85°C) | VFSO | 4.605 | 4.650 | 4.695 | Vdc | |
| Full Scale Span @ VS = 5.0 Volts(4) (0 to 85°C) | VFSS | 4.160 | 4.250 | 4.340 | Vdc | |
| Accuracy(5) (0 to 85°C) | --- | --- | --- | ± | 1.5 | %VFSS |
| Sensitivity | V/P | --- | 18.5 | --- | mV/kPa | |
| Response Time(6) | tR | --- | 1.0 | --- | mS | |
| Warm-Up Time(7) | --- | --- | 10 | --- | mS | |
| Offset Stability(8) | --- | --- | ±0.5 | --- | %VFSS | |
| Power ON Rise Time | tpon | --- | --- | 100 | mS | |
| Max Output | Vo-max | 96%Vs | Vdc | |||
| Min Output | Vo-min | 6%Vs | ` | Vdc | ||
1. Device is ratiometric within this specified excitation range.
2. Offset (Voff) is defined as the output voltage at the minimum rated pressure.
3. Full Scale Output (VFSO) is defined as the output voltage at the maximum or full rated pressure.
4. Full Scale Span (VFSS) is defined as the algebraic difference between the output voltage at full rated pressure and the output voltage at the minimum rated pressure.
5. Accuracy is the deviation in actual output from nominal output over the entire pressure range and temperature range as a percent of span at 25°C due to all sources of error including the following:
Linearity: Output deviation from a straight line relationship with pressure over the specified pressure range.
Temperature Hysteresis: Output deviation at any temperature within the operating temperature range, after the temperature is cycled to and from the minimum or maximum operating temperature points, with zero differential pressure applied.
Pressure Hysteresis: Output deviation at any pressure within the specified range, when this pressure is cycled to and from the minimum or
maximum rated pressure, at 25°C.
TcSpan: Output deviation over the temperature range of 0 to 85°C, relative to 25°C.
TcOffset: Output deviation with minimum rated pressure applied, over the temperature range of 0 to 85°C, relative to 25°C.Variation from Nominal: The variation from nominal values, for Offset or Full Scale Span, as a percent of VFSS, at 25°C.
6. Response Time is defined as the time for the incremental change in the output to go from 10% to 90% of its final value when subjected to a specified step change in pressure.
7. Warm-up Time is defined as the time required for the product to meet the specified output voltage after the Pressure has been stabilized.
8. Offset Stability is the product's output deviation when subjected to 1000 hours of Pulsed Pressure, Temperature Cycling with Bias Test.
Table 2 MAXIMUM RATINGS(1)
| Rating | Symbol | Value | Unit |
| Maximum Pressure(P1> | PMAX | 1000 | kPa |
| Storage Temperature | TSTG | -40° to+135° °C | °C |
| Operating Temperature | TA | -40° to+125° °C | °C |
| Output Source Current @ Full Scale Output(2) | Io+ | 2 | mAdc |
| Output Sink Current @ Minimum Pressure Offset(2) | Io- | -2 | mAdc |
Contact : Wendy Pan, 867147333084
Good deal: buying from seller
We invite you to read our terms of use. You can also visit our FAQ section and see our information section on the risks associated with counterfeiting.
|
This page is about importers and exporters of Manifold Absolute Pressure Sensor Search in a category : Vehicles Search in a category : absolute, pressure, manifold, sensor |
Saturday, June 18, 2022
Quantity : 100
Gril électrique professionnel pour des températures de gril de 850 ° C pour un steak parfait. • Brûleur céramique infrarouge haute performance de 1 600 watts • Idéal pour une croûte particulièrement croustillante • L'intérieur du steak reste toujours tendre et juteux - le plaisir...
MaKant Europe GmbH & Co. KG
- 60386 - Frankfurt am Main
- +49 (69) 9 150 750 14
Tuesday, May 03, 2022
France Vision Distribution spécialiste de l'import / export, déstockage et produits High-tech. Nous proposons une large gamme de produits a forte demande, contactez nous et visitez notre site internet pour plus d'informations. Site : www.france-vision-distribution.com Téléphone :...
France Vision Distribution
- 75015 - Paris
- 09 74 55 07 59
Thursday, June 30, 2022
Quantity : 100
Passez maintenant à la gestion dans le cloud Caractéristiques de multidiffusion Entrées IPv4 multicast 32 Nombre de groupes multicast filtrés 256 Support à la multidifusion Oui Données logistiques Largeur du carton principal 21.4 cm Longueur du carton principal 47.4 cm Quantité...
MaKant Europe GmbH & Co. KG
- 60386 - Frankfurt am Main
- +49 (69) 9 150 750 14