B2B Services

ELECTRODEIONIZATION (EDI)

EDI is a pure water manufacturing technology that combines ion exchange technology, ion exchange membrane technology and ion electromigration technology. It skillfully combines electrodialysis and ion exchange technology, uses high voltage of electrodes at both ends to move charged ions in water, and cooperates with ion exchange resin and selective resin membrane to accelerate the removal of ions, so as to achieve the purpose of water purification. During EDI desalination, ions are removed by ion exchange membrane under the action of electric field. At the same time, water molecules generate hydrogen ions and hydroxide ions under the action of electric field, which continuously regenerate the ion exchange resin to keep the ion exchange resin in the best state.

Technical Data of Electrodeionization Unit

Item

Reference value

Nominal Recovery:

90–95%

EDI Water Quality:

15–18 MΩ.CM25℃

FEED CONDUCTIVITY (INCLUDING CO2):

< 10 µs/cm25℃

Operating Temperature:

50–100° F

Maximum Inlet Pressure:

100 psig

Minimum Inlet Pressure:

60 psig

Expected Pressure Drop:

30–40 psig

Electrical Requirement:

380 VAC, 3-phase, 50 Hz.

OPERATING PRINCIPLES OF ELECTRODEIONIZATION

EDI Process

EDI desalination process is to exchange ions in water with hydroxide ions or hydrogen ions in ion exchange resin, and then migrate these ions into concentrated water

The above exchange reaction takes place in the freshwater chamber of the module. In the freshwater chamber, the hydroxide ion in the anion exchange resin exchanges with the anion in the water, and the hydrogen ion in the cation exchange resin exchanges with the cation in the water

The exchanged ions migrate along the surface of the resin ball under the effect of the DC electric field and enter the concentrated water chamber through the ion exchange membrane

The negatively charged anions are attracted by the anode, and these ions enter the adjacent concentrated water chamber through the anion membrane, while the adjacent cation membrane membrane does not allow them to pass through. These ions are blocked in the concentrated water, while the positively charged cations are attracted by the anion anion, and these ions enter the adjacent concentrated water chamber through the cation membrane, while the adjacent anion membrane does not allow them to pass through. These ions are blocked in the concentrated water.

In concentrated water, ions from both directions maintain electric neutrality. At the same time, the amount of current is proportional to the amount of ion migration. The amount of current consists of two parts, one part from the migration of removed ions, and the other part from the migration of water itself ionized into H+and OH - ions

When the water flow passes through the fresh water chamber and the concentrated water chamber, the ions gradually enter the adjacent concentrated water chamber from the fresh water chamber and are carried out of the EDI module by the concentrated water

Under the action of higher voltage gradient, water will generate a large amount of H+and OH- through electrolysis. These generated H+and OH- will continuously regenerate the ion exchange resin. Therefore, the ion exchange resin in EDI module does not need chemical regeneration

The above is the desalination process of EDI.

FEATURES OF ELECTRODEIONIZATION

1.

Regeneration of acid and alkali is not needed.

2.

Zero discharge; no discharge of wastewater.

3.

The running is continuous and the water quality is stable.

4.

Modularization design is adopted so as to facilitate extension.

5.

Less space is occupied.

If you want to know more kinds of electrodeionization system, please visit our website.

The water system in pharma is based on the preparation equipment, storage and export of purified water and water for injection and other functional units, optimized and combined by various functional modules, so as to ensure the high performance and quality of the whole system, and make the product water fully meet or exceed the water quality standards of purified water and water for injection.

Location : Room 4423, building 01, No. 88, Zhujiang Road, Xuanwu District, Nanjing, 210008 Nanjing,
Contact : .com biocell, 025 83192994

Good deal: buying from seller

Visit our guide for a secure transaction! Under no circumstances Algomtl can be held responsible for the content of the ads published. Only the sellers and buyers responsability is involved in case of dispute.
We invite you to read our terms of use. You can also visit our FAQ section and see our information section on the risks associated with counterfeiting.
This page is about importers and exporters of
ELECTRODEIONIZATION (EDI)

Search in a category : B2B Services
Search in a category :
electrodeionization
Taiwan 334 Equipment goods
Two Copies Piston Volumatical Filling Machine FP-425

Thursday, April 18, 2024

Dual Piston Volumatical Filling Machine FP425. available for working independently on each system. Cylinder Volume can be customized based on customer's requirement. FEATURES: - Filling volume can be customized based on customer's requirement - Each piston system can be set independently...

Autopack Co.,Ltd

Taiwan 334 Equipment goods
FT-100 Tabletop Peristaltic Pump Liquid Filling Machine

Saturday, April 27, 2024

Tabletop Peristaltic Pump Liquid Filling Machine FT-100 is the best system to avoid contamination, product is only in contact with the medically approved tubing and the nozzle, against cross contamination and easy cleaning. Without having to change anything but the dimension of the tubing in use...

Autopack Co.,Ltd

Honeysuckle Herbal Hydra Makeup Remover

Saturday, April 11, 2015

Price : $30

JCS Cosmetics is a professional skin care products manufacturer in Taiwan and provides a series of Honeysuckle Herbal Hydra products to meet customer's needs. This 3 in 1 product is a cleansing liquid, moisturizer and eye make-up remover combined into one convenient formula that...

JC's Cosmetics Co., Ltd.