CSCW-N180 Stick Curtain Wall
Stick built curtain wall CSCW-N180 is an efficient and reliable curtain wall system with 80mm width profile sightline. Compare to unitized curtain wall, it is flexible for different construction condition and structures, and offer a competitive product cost.
Overview of CSCW-N180 Stick Built Glass Curtain Wall
System |
Stick Curtain Wall (Non-Thermal Break) |
Model No. |
CSCW-N180 |
Material |
Aluminum Alloy/Glass/Aluminum Sheet/Aluminum Composite Panel/Galvanized Sheet |
Glass Type |
Tempered/Float/Laminated/DGU/Ceramic Fritted/LowE/Tinted/Reflective/Heat Soak |
Cooperated Glass Brand |
Vitro (Formerly PPG) /Pilkington/Xinyi(SYG)/Yaopi (SYP) /Fuyao/Southglass (SG) /Kibing/CNG/TaiwanGlass |
Surface Treatment |
Powder Coating/PVDF/Anodized/Electrophoresis/Wooden Grain |
Profile Brand |
6063-T5/6063-T6/6061-T6 (Brackets) |
Thermal Profile |
Non-Thermal Break |
Standards |
In Compliance With ASTM/AS/NZS/AAMA/NFRC/EN/BSI/ISO |
Application |
Residential Apartment, Villa/Commercial Hotel, Mall, Office, Public Organization |
System Customization |
Available |
Data of of CSCW-N180 Stick Built Curtain Wall System
Testing Data of CSCW-N180 Stick Curtain Wall
Design Wind Pressure |
Wsls=+1.61KPA/-2.09KAP, Wuls=+2.49KPA/-3.23KPA |
|
Test |
Pressure |
Results |
Preloading(Clause 8.2.2 of AS/NZS4284: 2008) |
+1.61kpa |
No separation, plastic deformations or deleterious was observed. |
-2.09kpa |
||
Preliminary Water Test under Static Pressure (Clause 8.2.3 of AS/NZS 4284: 2008) |
+482kPa |
There were no leaks. |
Preliminary Water Test under Cyclic Pressure (Clause 8.2.3 of AS/NZS 4284: 2008) |
241-482-241 (Pa) |
There were no leaks. |
321-642-321 (Pa) |
||
482-964-482 (Pa) |
||
Structural Test at Serviceability Limit State Wind Pressure (Wsls)(Clause 8.3 of AS/NZS 4284: 2008) |
+1.61kpa |
During the structural test at SLS wind pressure, the deflections of all related members were within the allowable deflection limits. |
-2.09kpa |
||
Air Infiltration Test (Clause 8.4 of AS/NZS 4284: 2008) |
+/-165Pa |
The rate of air leakage of the specimen was within the allowable values. |
Water Test under Static Water Test under Static 4284: 2008) |
+482Pa |
There were no leaks. |
Water Test under Cyclic Pressure (Clause 8.6 of AS/NZS 4284: 2008) |
241-482-241 (Pa) |
There were no leaks. |
321-642-321 (Pa) |
||
482-964-482 (Pa) |
||
Structural ProofTest at Ultimate Limit State Wind Pressure (Wuls) (Clause 8.8 of AS/NZS 4284: 2008) |
+2.49kpa |
No collapse of the test specimen was observed under the specified pressure. |
-3.23kpa |
||
Seal Degradation Test(Clause 8.10 of AS/NZS 4284: 2008) |
241-482-241 (Pa) |
No water leakage was observed. |
321-642-321 (Pa) |
||
482-964-482 (Pa) |
Thermal Data of CSCW-N180 Stick Curtain Wall
NFRC Procedures |
NFRC100SB, NFRC200-2010, and NFRC500-2010 |
Software Tools |
THERM 7.4.3.0 and WINDOW 7.4.6.0 |
Configuration |
6 CLR-TDE33D 8mm HS #2 + 12AR + CLR 10mm HS IGU |
Panel Dimension |
1705mm Wide 3245mm High |
Frame |
Painted Aluminum |
Panel U-value |
3.041W/m2k |
Visible Light Transmission |
0.271 |
SHGC |
0.197 |
Frame Data of CSCW-N180 Stick Curtain Wall
Parts Location |
Frame Area/m2 |
Edge Area/m2 |
U-Value(Frame) |
U-Value(Edge) |
W/m2k |
W/m2k |
|||
Header |
0.0638 |
0.0946 |
4.60438 |
1.31648 |
Left Jamb |
0.1397 |
0.1826 |
16.32147 |
1.85603 |
Right Jamb |
0.1397 |
0.1826 |
26.14535 |
2.18867 |
Sill |
0.3608 |
0.0946 |
6.32962 |
1.72348 |
Glass Data of CSCW-N180 Stick Curtain Wall
Glass Data: CLR-TDE33D 8mm HS #2 + 12AR + CLR 10mm HS IGU |
|||||||
Visible Light |
SHGC |
SC |
NFRC U-value |
STC |
|||
W/m3k(Argon) |
|||||||
T% |
R-out% |
R-in% |
Winter |
Summer |
|||
31.9 |
20.9 |
16.5 |
0.209 |
0.242 |
1.705 |
1.694 |
39.6 |
Benefit of of CSCW-N180 Stick Built Glass Walls
Certified performances in terms of air, water tightness and wind pressure.
Flexible for on-site installation
Cost efficient product compare to competition
Vast alternatives in custom solutions tailor made to the building
Enhancement of natural light
Increased static robustness, even in extreme natural phenomena
Minimum after sales service & maintaining
Increased comfort level
Recommended CAS Facade Products
Our facade products are designed to snap together perfectly, organically or with the help of couplers. This ensures a streamline design throughout your project. Below is a list of compatible products.
Contact : facade Cas, 0757 87655056
Good deal: buying from seller
We invite you to read our terms of use. You can also visit our FAQ section and see our information section on the risks associated with counterfeiting.
This page is about importers and exporters of CSCW-N180 Stick Curtain Wall Search in a category : Everything else / Bulk Search in a category : stick, n180, cscw, wall, curtain |
Thursday, December 19, 2024
- High Speed Front and Back Labeling Machine - Model No.: LD-450S High Speed Front and Back Labeling Machine LD-450S is ideal for simultaneously applying Front and Back pressure sensitive labels to a container. It suits for Round Oval, Square, Rectangular or Irregular products labeling...
Autopack Co.,Ltd
- autopacker
- 33454 - Taoyuan City
- +88 6 33 68 98 06
Thursday, December 12, 2024
Quantity : 10
- High Speed Front and Back Labeling Machine - Model No.: LD-350S High Speed Front and Back Labeling Machine LD-350S is ideal for simultaniously applying Front and Back pressure sensitive labels to a container.It suits for Round Oval, Square ,Rectangular or Irregular products labeling...
Autopack Co.,Ltd
- autopacker
- 33454 - Taoyuan City
- +88 6 33 68 98 06
Sunday, July 26, 2015
We love what we do. No matter what item we are dealing in, we try our best to provide our customers with the best quality products and services. We feel very proud with our customers' responses. We like nothing more than to hear from our customer and invite them to reach us any time...
TRADEX GROUP CO LTD
- 15140 - opburi
- +6661409539