Equipment goods

Cross Flow Cooling Tower

Cross flow type cooling tower is an induced draft cooling tower that can cool water. The water flows vertically from the top of the tower, and the air flows horizontally through the filler. The air flow is orthogonal to the water flow in the cooling tower.

The cooling tower is often used in residential areas with strict noise requirements, and it is a cooling circulating tower used more frequently in the air conditioning industry.

Cross Flow and Counter Flow Cooling Tower

Technical Comparison Between Counter Flow Cooling Tower And Cross flow Cooling Tower

Project

Counter Flow Cooling Tower

Cross Flow Cooling Tower

Tower Height

Due to the height of the air inlet and the horizontal arrangement of the water eliminator,the total height of the counter flow tower is high and the volume is large.

Because the height of packing is close to the tower height and the water
eliminator does not occupy the height, the total height of cross flow tower is low and the volume is small.

Water Distribution System

The counter flow tower adopts the nozzle to distribute water, which has higher requirements on the pressure head and the nozzle is easy to be blocked.

The cross flow tower adopts the water distribution system of gravity falling naturally, so the water dispersion hole is not easy to be blocked, and the water distribution is uniform, which improves the packing performance to the maximum.

Overhaul

The whole body of counter flow tower is a closed structure, so it should be shut down during equipment maintenance or routine maintenance.

The cross flow tower body is equipped with an access door, and there is room for maintenance inside the tower, so that the equipment can be overhauled and maintained without shutdown.

Wind Resistance

Due to the reverse flow of water and gas in the counter flow tower and the obstruction of water distribution to the air flow, the wind resistance is high and the power consumption of the motor is large.

The cross flow tower is lower than the counter flow tower, and the high air inlet means the high packing, so the air inlet speed is low and the motor power consumption is low.

Noise

There is a large distance between the packing of counter flow tower and the lower water tank. After the water falls from the packing, there is a loud noise.

A small part of the lower part of the packing of the cross flow tower is submerged in the water, so that the water flows directly into the lower water tank after passing through the packing surface, and the noise is very low.

Water Loss

Because the fan of counter flow tower is located directly above the packing and the distance is close, the water drift is large. In addition, the splash loss of the water in the lower tank is very large, and it is easy to form water mist around the cooling tower, which is easy to cause the reproduction of Legionella.

The cross flow tower fan is located in the center of the cooling tower, and the packing is located on both sides, so the water drift is very small, which is an environmental protection product.

Modularization

The unit of counter flow tower is
supplied with air from all sides, and the air inlet surface is reduced after module combination, which affects the air inlet volume.The power consumption of the motor will increase.

The cross flow tower is specially designed for modularization,
with air inlet from both sides of the unit. After the combination of the modules, the air inlet has no change, and the power consumption of the motor remains unchanged.

Characteristics of Cross Flow Type Cooling Tower

Energy-saving, low water pressure, small wind resistance, low-speed motor, no dripping noise and wind noise, and convenient maintenance of filler and water distribution system.

According to the shape of the building, the foundation can be built randomly, and multiple cell cooling towers can be started according to the water temperature required.

Advantages of Cross Flow Cooling Tower

As a major cooling tower inc, our cross flow cooling tower casing is made by machine. It makes the casing have a smooth surface and good quantity.

The motor driver we using belt reducer with low noise characteristic. The belt is very stronger, clients no need to replace it frequently. If you choose a cross-flow closed circular cooling tower, we will use a cooling tower direct drive motor.

The fresh air comes from the cooling tower tow side continuous, the fresh air will take water heat continuously.

Zhejiang Aoshuai Refrigeration Co., Ltd., a professional supplier of cooling towers llc, is a specialized manufacturer of cooling towers and cooling tower parts. Contact us for more information about cross flow cooling tower design.

Location : Lingjiang Village,Dongguan Street,Shangyu District,Shaoxi ng City, Zhejiang Province,China, 312300 Shaoxing,
Contact : AUVC ctauvc, 057582331987

Good deal: buying from seller

Visit our guide for a secure transaction! Under no circumstances Algomtl can be held responsible for the content of the ads published. Only the sellers and buyers responsability is involved in case of dispute.
We invite you to read our terms of use. You can also visit our FAQ section and see our information section on the risks associated with counterfeiting.
This page is about importers and exporters of
Cross Flow Cooling Tower

Search in a category : Equipment goods
Search in a category :
flow, cooling, cross, tower
Thailand 50000 Food
New Products 2016 Dried Apricot,Dried Peach and Green Raisin

Tuesday, February 16, 2016

Quantity : 1000 - Price : 1500 USD/ MT CIF

We are a professional manufacture and exporter of dried apricot, raisin and goji berry, we can supply you dried apricot, brown raisin, golden raisin, green raisin and goji berry with high quality and competitive prices. We can do small pack and bulk pack as buyers' requirements,...

KHUN JACK PARTNERSHIP LIMITED

  • 50000 - CHIANG MAI
  • +66 9 56 19 49 81
Turkey 84000 Vehicles
ALTERNATİVE JCB spare parts for JCB 3CX and JCB 4CX

Friday, December 15, 2017

OEM PART NO DESCRİPİTİON 66072 Crown Wheel and Pinion FOR CARRARO 13X30 66941 Crown Wheel and Pinion 15x37 2277448 CATERPİLLAR AİR FİLTER OUTER 2277449 CATERPİLLAR AİR FİLTER İNNER 01/117901 FAN BELT 01/124403 FAN BELT 01/124404 02/100073 Oil Filter Canister Type, MEDİUM MODEL 02/100284...

ANAC MAKINA CO LTD STI

  • 34800 - İSTANBUL
  • +905069691531
  • +9005069691531
Morocco 81000 Food
photo not available

Saturday, February 16, 2013

Quantity : sur comand - Price : à négocier

Our processing unit of seafood for freezing is located in the basement of our hotel, already approved for the treatment of fresh fish, located in the Port tantan extra port in Morocco. - Total area of 630 m2. - Drinking water supply, electricity, sewerage with a directly connected...

FRIGO BOUCHTA

  • 81000 - TANTAN PORT
  • 00212627520977