Cooling Tower Sprinkler Head

The cooling tower sprinkler head is a special water distributor for small and medium-sized round counter flow cooling tower. Through the small holes on the water distribution pipe, the water is evenly spread on the filler, increasing the water vapor contact interface, so that cooling tower sprinkler head parts and takes away heat, thus reducing the water temperature.

Material of Cooling Tower Sprinkler Head

ABS, nylon, nylon copper, aluminum alloy.

Maintenance Points of Sprinkler Head in Cooling Tower

a. When installing the sprinkler for cooling tower, check outside the tower first, and arrange the sprinkler head and water distribution pipe of sprinkler head cooling tower. Check whether the bearing and diameter of sprinkler head of cooling tower are consistent with the diameter of water inlet of cooling tower.

b. Clean the water inlet of cooling tower and grind it. (here are the necessary steps for cooling tower maintenance)

c. Lift the sprinkler head of the cooling tower into the tower and then place the sprinkler head on the water inlet smoothly. Here we should pay attention to the construction of the cooling tower filler to lay wood, so as not to damage the filler. Then tighten the water inlet and sprinkler head with nuts, diagonally. Prevent the sprinkler head from imbalance.

d. Find the level ruler you brought in advance and put it on the sprinkler head. Adjust the sprinkler head according to the level to the balance position.

e. Then install the water distribution pipe in turn, and the water distribution pipe shall present a 30°angle with the packing plane of the cooling tower. And the spray direction of each water distribution pipe should be consistent.

f. After the installation, manually wave the water distribution pipe. Check whether the rotation is normal and whether there is friction on the tower body.

Characteristics of Sprinkler Head in Cooling Tower

a. Durable

The cooling tower sprinkler head is corrosion resistant, high-strength, water and gas resistant, beautiful and durable, and it does not need maintenance for 3 years.

b. Low outlet pressure

The working pressure at the outlet of the nozzle is only 0.6mh2o, which has a large pressure adaptation range, low cost and stable quality.

c. Safe and reliable

If the nozzle of the cooling tower is damaged for various reasons, the cooling tower sprinkler head can be replaced in time, shorten the time of cooling tower sprinkler system recovery and alert state, so as to be safe and reliable in use.

d. Anti clogging

The spray head of cooling tower is easy to clean, makes the water distribution even and not easy to block, which is conducive to improve the cooling effect of cooling tower.

e. Easy to maintain

The nozzle of the cooling tower is very small, which is easy to block, which causes uneven water distribution and convenient maintenance.

Our cooling tower company provides cooling tower filling, drift eliminator, fan, motor, gearbox, belt reducer, spray nozzle, sprinkler head, float ball, air inlet louvers, etc... Whatever cooling tower parts you need, you will find them in our cooling towers LLC AUVC.

Location : Lingjiang Village,Dongguan Street,Shangyu District,Shaoxi ng City, Zhejiang Province,China, 312300 Shaoxing,
Contact : AUVC ctauvc, 057582331987

Good deal: buying from seller

Visit our guide for a secure transaction! Under no circumstances Algomtl can be held responsible for the content of the ads published. Only the sellers and buyers responsability is involved in case of dispute.
We invite you to read our terms of use. You can also visit our FAQ section and see our information section on the risks associated with counterfeiting.
This page is about importers and exporters of
Cooling Tower Sprinkler Head

Search in a category : Shoes and leather
Search in a category :
cooling, sprinkler, head, tower
Taiwan 334 Equipment goods
High Speed Front and Back Labeling Machine LD-350S

Thursday, March 20, 2025

Quantity : 10

- High Speed Front and Back Labeling Machine - Model No.: LD-350S High Speed Front and Back Labeling Machine LD-350S is ideal for simultaniously applying Front and Back pressure sensitive labels to a container.It suits for Round Oval, Square ,Rectangular or Irregular products labeling...

Autopack Co.,Ltd

Hong Kong 999077 Equipment goods
APIwellhead

Saturday, June 29, 2013

Quantity : 1 - Price : USD2310

Wellhead Function: During drilling operation, casing head is an important equipment for controlling wellhead pressure. Raw Material: Carbon steel or low alloy steel comply with API Spec.6A. Applied Casing Program: 20"×13-3/8"×9-5/8"× 7"×5-1/2", or as user's requirements. Bottom Connection...

Kergy Oilfield Equipment Co.,LTD

  • kergy
  • 999077 - HongKong
  • 86 15399023516
Hong Kong 614000 Vehicles
Sell TOYOTA cylinder gasket

Saturday, January 19, 2013

Quantity : 1 - Price : 0.7 USD

OEM:11115-16082 Model:4AF/4AFE Cylinder diameter:83 mm Connecting diameter:83 mm Displacement:2400(cc) Cylinder:4 Material: asbestos Cylinder head gasket for other brands are also available from us: FORD:CVH N8B 4HV 250 CHV OHC 99L MEBA ZETEC V6 V6ESSEC M42 M44 CDRA ... BMW...

HONGYUE SPARE PARTS TRADING CO., LIMITED

  • 614000 - LESHAN
  • 86 833 2412124