C01 Sleep Therapy System (Household Ventilator)
Product Profile:
Sleep apnea syndrome has been gradually taken to a serious threat of the most common illnesses to human health, has become invisible killer of lifethreatening at recently 30 years. Sleep apnea syndrome prevalence rate is 4% in the population, and the rate is 20% to 40% in people over 65 ages. The main feature of sleep apnea syndrome is that the patients have recurrent apnea during sleep and cause hypoxia leading to the ultimate consequences of cardiovascular and cerebrovascular disease, diabetes and other damage to many organs. 80% of drug resistant hypertension, 50% to 70% of congestive heart failure, nearly 50% of atrial fibrillation and diabetes has relationship with sleep apnea syndrome.
Since 1981, Dr. Sullivan from Australia firstly use continuous positive airway pressure breathing machine (CPAP) to treat the sleep apnea syndrome (OSA). Because of its safety, effective, less side effects, and efficient treatment characteristics, CPAP get more and more widely used. CPAP adapt to all types of sleep apnea hypopnea syndrome treatment, especially more effective for moderate and severe obstructive sleep apnea syndrome patients. In the various methods of treatment of sleep apnea syndrome at home and abroad, CPAP treatment accounted for 70-80% utilization.
Our company is grand to launch the ARI series CPAP/Auto CPAP, it has accurate and stable pressure output, incorporate humidifier, ramp up time setting and Auto On/Off functions, those will provide more comfortable during the sleep. Look forward to your finding more features.
Characteristic:
1. 3.5" TFT or 64X128 LCD Screen, ensures a friendly user interface.
2. One button operation makes the parameter setting easy;
3. Constant temperature humidifier can ensure comfortable airflow for patients;
4. The 0-60 minute ramp durations ensure patients fall asleep peacefully;
5. The latest technology of the different pressure sensor and automatic leakage and altitude compensation ensure the therapy accuracy anywhere.
6. Customized Germany motor and special sound-insulation material and design make noise low and let patients sleep well.
7. Patient breathing with the mask can trigger the machine automatically enter into working mode; Taking off the mask in working mode can make it into standby status automatically after 15 seconds, which is very safe and reliable.
8. Internal intelligent flash record every using case including real-time data, event information, etc. A USB port is provided for data download.
9. The intelligent monitoring system can provide an alarm timely, in case of any sudden power failure to ensure the safety treatment.
10. Automatic pressure titration for Auto-CPAP: Monitoring the real-time breath condition to finish the pressure titration automatically and separated from PSG or by hand to meet all kinds of requirements.
Specifications |
||||||||
|
||||||||
Name |
CPAP |
AutoCPAP |
BiPAP |
|||||
Model |
C02 |
C01 |
AC09 |
AC08 |
B19 |
B18 |
||
Colour |
Gray Shell / White Black Screen |
Silvery Shell/ Color Screen |
Silvery Shell / Color Screen |
Gray Shell/White Black Screen |
Silvery Shell/ Color Screen |
Gray Shell/White Black Screen |
||
Display |
3.5” TFT LCD |
128*64 LCD |
3.5” TFT LCD |
128*64 LCD |
3.5” TFT LCD |
128*64 LCD |
||
Working Mode |
||||||||
CPAP |
Y |
Y |
Y |
Y |
Y |
Y |
||
CPAP+EPR |
Y |
Y |
Y |
Y |
Y |
Y |
||
Auto CPAP |
Y |
Y |
||||||
Titration |
|
|
Y |
Y |
|
|
||
S |
Y |
|||||||
T |
Y |
|||||||
S/T |
Y |
Y |
||||||
Main Function |
||||||||
Pressure (increment 0.5 cmH2O) |
4-20cmH2O |
4-20cmH2O |
4-20cmH2O |
4-20cmH2O |
4-20cmH2O |
4-20cmH2O |
||
IPAP (increment 0.5 cmH2O) |
4-20cmH2O |
4-20cmH2O |
||||||
EPAP (increment 0.5 cmH2O) |
4-20cmH2O |
4-20cmH2O |
||||||
EPR (1-3 level) |
2-4 cmH2O |
2-4cmH2O |
2-4cmH2O |
2-4cmH2O |
2-4cmH2O |
2-4cmH2O |
||
Inspiration sensitivity (1-6 level) |
|
|
|
|
|
Y |
||
Expiration sensitivity (1-6 level) |
|
|
|
|
|
Y |
||
Respiratory Rate |
|
|
|
|
4-40 BPM |
4-40 BPM |
||
Inspiration time (0.5-3.0s) |
|
|
|
|
Y |
Y |
||
Ramp duration |
0-60 Min. |
0-60 Min. |
0-60 Min. |
0-60 Min. |
0-60 Min. |
0-60 Min. |
||
Automatic leakage compensation |
Y |
Y |
Y |
Y |
Y |
Y |
||
Automatic attitude compensation |
Y |
Y |
Y |
Y |
Y |
Y |
||
Auto ON/OFF |
Y |
Y |
Y |
Y |
Y |
Y |
||
Power Adapter (110-240Vac) |
Y |
Y |
Y |
Y |
Y |
Y |
||
Humidifier
|
||||||||
Adjustable constant temperature humidification system |
Y |
Y |
Y |
Y |
Y |
Y |
||
Replaceable water chamber (Max. 200ml) |
Y |
Y |
Y |
Y |
Y |
Y |
||
Alarms |
||||||||
Alarm for power off or disconnected |
Y |
Y |
Y |
Y |
Y |
Y |
||
Heated Humidifier |
Y |
Y |
Y |
Y |
Y |
Y |
||
Data Download |
||||||||
Data In Total (Apnea Hyponea Index /Data analysis, Adaptability, Usage Time) |
Y |
Y |
Y |
Y |
||||
Data In Details (AHI, Event, Pressure and Respiratory Flow) |
Y |
Y |
Y |
Y |
Y |
Y |
||
USB Connected With PC |
Y |
Y |
Y |
Y |
Y |
Y |
||
Other specification |
||||||||
Noise |
<30dBA (10cmH2O)</p> |
|||||||
System Time |
24hours |
|||||||
Backlight Time |
30,60,120,300,600 Seconds |
|||||||
Electrical specification |
Input: 100-240V,50-60Hz,1.7A Output: 24V,2.5A Class II, Type BF Applied Part |
|||||||
Work Environment |
T: 5℃-35℃, H: 15%-95%(No condensation),P: 77-101kPa |
|||||||
Storage Environment |
T: 20℃-60℃, H: 15%-95%(No condensation) |
|||||||
Waterproof grade |
IPX1 |
|||||||
Dimension,Weight |
390mm*280mm*195mm,1.0Kg (Host+Humidifier) |
Contact : Rachel Zhang, 86 755 27196156
Good deal: buying from seller
We invite you to read our terms of use. You can also visit our FAQ section and see our information section on the risks associated with counterfeiting.
This page is about importers and exporters of C01 Sleep Therapy System (Household Ventilator) Search in a category : Medical Search in a category : therapy, ventilator, sleep, system, household |
Thursday, June 30, 2022
Quantity : 100
Restez concentré avec ce casque anti-transpiration. Il vous accompagne dans vos mouvements tout en offrant un son limpide aux basses énergisantes. La conception flexible des tours d'oreilles permet de maintenir les écouteurs en place, tandis que le fil de 1,2 m est d'une longueur...
MaKant Europe GmbH & Co. KG
- 60386 - Frankfurt am Main
- +49 (69) 9 150 750 14
Wednesday, February 22, 2017
Small dogs have a very short and intensive growing period. If supplied with sufficient energy and protein they will multiply their body weight by 20 within 10 months. Small dogs who are fed correctly as puppies may reach an age of 13 to 16 years. Royal Canin Mini Junior dry dog...
Pet Food UK International Limited
- N20 9YZ - LONDON
- +447405858765
Thursday, June 30, 2022
Quantity : 100
Restez concentré avec ce casque anti-transpiration. Il vous accompagne dans vos mouvements tout en offrant un son limpide aux basses énergisantes. La conception flexible des tours d'oreilles permet de maintenir les écouteurs en place, tandis que le fil de 1,2 m est d'une longueur...
MaKant Europe GmbH & Co. KG
- 60386 - Frankfurt am Main
- +49 (69) 9 150 750 14