MATRIX - 931 ads
Monday, September 23, 2019
The reason for the QuEChERS matrix effect in the liquid state is generally considered to be due to the non-volatile components in the matrix and the substance to be tested, which competes in the ionization process. The matrix effect in gas phase temperament is generally attributed...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Friday, September 20, 2019
Quantity : 1 - Price : 0,10 €
Cheapest Factory Electronic Price Tag 4.2 inches Smart Electronic Display Wireless ESL for Supermarket or Store 1. Screen size 4.2 inches; 2. Communication band 2.4Ghz; 3. Screen type EPD dot matrix electronic paper, black and white,black and white and red,black and white and yellow; 4...
Highton Electronics CO.,LTD
- hightonsales8
- 518103 - Shenzhen
- +8619926547196
- +8675529899911
Friday, September 20, 2019
Silica matrix HPLC columns are generally compatible, but organic polymer matrix columns may expand or contract in some solvent combinations, which will affect their chromatographic behavior. Wash each solvent system at least 20 volumes. Because some solvent systems are highly viscous...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Friday, September 20, 2019
Solid phase extraction is essentially a liquid chromatographic separation. The main separation mode is the same as that of liquid chromatography. It can be divided into normal phase (the polarity of the adsorbent is greater than the polarity of the eluent), and the reverse phase (the...)
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Wednesday, September 18, 2019
Selection of scavengers The conventional QuEChERS method only uses PSA which is too simple single that can no longer meet the complex matrix samples examination experiments. GCB (graphitized carbon black) can effectively adsorb pigments, non-polar interferences such as sterol due...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Monday, September 16, 2019
Reversed phase chromatography (RP) is the most widely used technique in high-performance liquid chromatography (HPLC) up to now, mainly because it is suitable for the analysis of most of them. Nonpolar substances and many ionizable and ionic compounds. Most stationary phases used...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Wednesday, September 11, 2019
Quantity : 2000sqm/mo - Price : 500~2000usd/sqm
LED Rental LED Display VI2.6 | VI2.9 | VI3.9 | VI4.8 | VI5.9 VO3.9 | VO4.8 | VO5.9 Front Maintenance Curved Installation Edge-care Design No Light Leakage Light and Thin Parameter V Series Outdoor VO 3.9 VO 4.8 VO 5.9 Pixel Pitch(mm) 3.91mm 4.81mm 5.95mm Pixel Matrix Per Sq...
Shenzhen LEDFUL Optoelectronics Co., Ltd.
- 518103 - Bao'an
- +13 5 30 17 24 35
Wednesday, September 11, 2019
Quantity : 2000sqm/mo - Price : 500~2000usd/sqm
Outdoor Commercial Advertising LED Display OF4 | OF5 | OF6 | OF8 | OF10S | OF10D | OF16S Energy saving to save cost Front maintenance to save space Wifi, 4G, cloud, usb, remote control All weather resistant for stable operation High brightness provide perfect performance Parameter...
Shenzhen LEDFUL Optoelectronics Co., Ltd.
- 518103 - Bao'an
- +13 5 30 17 24 35
Tuesday, September 10, 2019
1. Advantages and disadvantages of commonly used extraction solvents Acetonitrile: easy to salt out; compatible with LC/MS; difficult to concentrate Acetone: not easy to salt out; easy to volatilize, concentrate Ethyl acetate: immiscible with water; less extraction of impurities;...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Tuesday, September 03, 2019
The basic principle of SPE cartridges is that the liquid sample is made to pass through the adsorbent to retain the tested substance, and then the impurities are washed away with appropriate strength solvent, and then the tested substance is eluted with a small amount of good solvent...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Friday, August 30, 2019
Quantity : 100-1,000, - Price : 20s
Eolane SCM is a professional OLED screen manufacturer. We provide a wide range of standard passive matrix OLED (PMOLED,Graphic OLED displays with board and OLED display panels. Mechanical construction includes Chip on Board (COB), Chip on Glass (COG), and TAB (Tape Automated Bonded) types...)
Eolane Supply Chain Management (Shanghai) Co., Ltd.
- eolanescm
- 215129 - Suzhou
- +86 (0)512 8885 9567
Friday, August 30, 2019
Quantity : 100-1,000, - Price : 20s
We are custom made lcd display manufacturer, specializing in a wide range of TFT and passive matrix Liquid Crystal Display technologies, and etc. : Wide viewing angles, wide color gamut, high contrast, sunlight readability, extreme temperature functionality and more. Even more, we...
Eolane Supply Chain Management (Shanghai) Co., Ltd.
- eolanescm
- 215129 - Suzhou
- +86 (0)512 8885 9567
Friday, August 16, 2019
NH2 HPLC columns refer to the chromatographic columns that use silica gel as matrix carrier to bond amino groups. They are usually used for the analysis of carbohydrate compounds, and the mobile phase is usually methanol, acetonitrile and buffers salt solution. - The cleaning method...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Friday, August 16, 2019
- Category - In terms of the filler type, SPE column can be divided into four applications of silicone bonding matrix, polymer matrix, absorption matrix and specialized columns. Besides, the silicone bonding has four sorts—antiphase(C18 sealing end/uncapped/hydrophile, C8), positive...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Thursday, August 15, 2019
Review the article that I had written for product introductions, it seems that the content which making fun of products basically does not have, a person with the label of “warm person heart” is wearing very tired. The things about making fun are so cool to be said completely by naked...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Wednesday, August 14, 2019
After years of development, the QuEChERS pretreatme nt method has been continuously improved and broadened by researchers as a simple and rapid residual pretreatment technology. The application target also has been extended from the highest moisture content of vegetables and fruits...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Wednesday, August 14, 2019
The important technical parameters of Hawach SPE Columns are the key points of selection. Material The material selection of the SPE column is very important. The column material is in direct contact with the test object or analyte. The quality of material selection determines the...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Monday, August 12, 2019
Solid phase extraction principle Solid phase extraction is a separation technique that combines selective retention, selective elution, and the like. When a complex sample solution passes through the sorbent, the sorbent selectively retains the aimed compound and a small number of...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Thursday, August 08, 2019
Most common SPE cartridges are injection syringes made of polyethylene, in which there are two plugs made of polypropylene or fiberglass, with a certain amount of chromatographic adsorbent (filler) between the two plugs. SPE cartridges without sieve plate 1. Avoid “non-specific adsorption” 2...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Wednesday, August 07, 2019
Food safety testing is a major issue related to people's livelihood. In recent years, the QuEChERS method has been widely used in the pretreatment of food safety detection samples. In addition, the method has been applied to trace analysis. QuEChERS Application The international application...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Tuesday, August 06, 2019
Ion-exchange solid phase extraction is widely used in biological samples and environmental monitoring. During the extraction process, the pH of the sample is adjusted so that the solute is easily ionized. The solute is exchanged from the resin by changing the pH or increasing the...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Thursday, August 01, 2019
There are two different cases of retention time: retention time drift and retention time fluctuations. The former means that the retention time changes only in one direction, while the latter refers to the fluctuation of the retention time without a fixed law. It is often helpful...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Tuesday, July 30, 2019
Since its birth, the QuEChERS method has been widely used in pesticide residue analysis due to its unique advantages and characteristics of fast, simple and cheap. Lehotay et al. established a method, which uses the QuEChERS method to treat samples and analyze 229 kinds of pesticides...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Friday, July 19, 2019
Bonded-phase chromatography is a liquid-liquid chromatography method in which a stationary phase is covalently bound to a carrier particle, which overcomes the mechanical shock in the distribution chromatography, the constant loss of the stationary phase and the gradual change of...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Friday, July 12, 2019
Today, Hawach want to talk about the pre-treatment process for pesticide residue detection from the perspective of food safety – QuEChERS, and also tell you how to pre-treat pesticide residue food. Introduction The present analytical methods and determining techniques, pre-treatment...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Thursday, July 11, 2019
With the development of society and technology, chromatographic analysis theory has also been developing rapidly. HPLC column has now been widely applied in every field of laboratory analysis. HPLC column gathers function of both detection and separation. With the right choice, use...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Thursday, July 11, 2019
With the development of society and technology, chromatographic analysis theory has also been developing rapidly. HPLC column has now been widely applied in every field of laboratory analysis. HPLC column gathers function of both detection and separation. With the right choice, use...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Tuesday, July 09, 2019
Polymeric MCX SPE cartridges are used to extract strongly alkaline compounds. MCX is a mixed strong cation exchange adsorbent obtained by bonding sulfonic acid groups on highly crosslinked PS/DVB surface. It has both reverse phase and cationic exchange retentive properties and good...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Tuesday, July 02, 2019
The average sample addition recovery rate of QuEChERS method is higher than 85%, with fewer impurities interfering with the detection of the target substance, a small amount of solvent, simple and fast operation, which will be the preferred pretreatment method for routine detection...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33
Monday, June 24, 2019
QuEChERS is widely used in many areas, in the case that the targeting recovery rate satisfies the need, and also the matrix background of removing impurities meets detection, it can be applied to purify stuff such as residues of food and veterinary, additives, plasticizers. However...
Hawach Scientific Co.,Ltd.
- 710077 - Xi'an
- +86 29 89284429
- +15 1 02 91 81 33




