China Clothes
Clothes

Auto Relays

Auto off relay control higher voltages or currents by using lower voltages or currents. When a certain voltage or current is applied to both ends of the electromagnetic relay coil, the magnetic flux generated by the coil passes through the magnetic circuit composed of the iron core, the yoke, the armature and the working air gap of the magnetic circuit. Under the action of the magnetic field, the armature is attracted to the pole face of the iron core. Therefore, the normally closed contact of the contact is pushed to be disconnected, and the normally open contact is closed. When the voltage or current at both ends of the coil is less than a certain value, and the mechanical reaction force is greater than the electromagnetic attraction force, the armature will return to the initial state, the normally open contact is disconnected and normally closed contact is on.

Key Features of Auto Relays

With charatstic of high switching load power, high shock and vibration resistance.

Power 12V.

Power consumption 1.62W.

Ambient temperature -40℃125℃.

How To Test Auto Relays?

(1) A simple method for judging the working performance of the auto relays.

Turn on the ignition auto relay switch, and then use your ear or stethoscope to listen to the sound of the control relay, or feel the vibration of the relay with your hand. If there is vibration, then the auto relays is working well, the electrical appliance does not work due to other reasons. Otherwise, the relay is not working properly.

You can also unplug the auto recloser relay for testing, for example, if the air conditioner compressor does not work, you can start the engine, turn on the blower switch and the air conditioner switch. Then unplug the connector of the air conditioner compressor relay to judge. If the sound of the relay action can be heard, the engine speed drops significantly when the relay is unplugged, and the engine speed rises when the auto relays is inserted, it means that the air conditioner compressor relay and its control circuit are normal.
(2) Common failures of relays.
Common failure phenomena of relays include coil burnout, inter-turn short circuit or insulation aging, contact ablation, thermal decay, and inability to adjust the initial operating current.
①The relay coil is burnt out. In order to prevent this from happening, if the temperature may exceed 80°C during repair, maintenance and electric welding, the temperature-sensitive relays and electronic control units should be removed.
② Contact ablation. For example, vehicle with 491Q-ME engine, the relay of the air conditioner condenser fan is just below the glass cleaning spray pipe. If the spray pipe is broken, the cleaning fluid will leak to the relay, making the relay normally open contact is corroded and cannot be disconnected, which will lead to the failure of the air conditioner condenser fan to keep running. Therefore, water should be strictly prevented from entering the relay.
(3) Try to reduce the contact resistance of the relay contact.
The contact resistance existing between the contacts of the automotive relay is mainly composed of shrinkage resistance and surface film resistance. The contact resistance of the contact is related to the contact form, material properties and surface processing of the contact. It can be seen that to reduce the contact resistance of the relay contacts, under the condition of a certain contact pressure, it can be started by improving the contact state and improving the contact material.
(4) Poor grounding of the ECU may affect the normal operation of the relay.

Now the price of auto spares sale is reasonable, if you have needs, please contact us.

Location : Room 1505, F15, Bldg T2, 2 Yichuang St, Huangpu 510555, Guangzhou, China, 510555 Guangzhou,
Contact : MAPMS MAPMS, +86 139 2617 0287

Good deal: buying from seller

Visit our guide for a secure transaction! Under no circumstances Algomtl can be held responsible for the content of the ads published. Only the sellers and buyers responsability is involved in case of dispute.
We invite you to read our terms of use. You can also visit our FAQ section and see our information section on the risks associated with counterfeiting.
This page is about importers and exporters of
Auto Relays

Search in a category : Clothes
Search in a category :
relays, auto
India 500020 B2B Services
Save Money Save Power With Active plus solar water heater

Thursday, October 08, 2015

ACTIVE PLUS - the name that stands for "Quality, Reliability and Long life". Active plus solar, the manufacturer, is one of the pioneers in promoting use of solar water heaters. Emmvee Solar manufactures eco-friendly and pollution free products that not only go a long way in helping...

ACE

  • 500020 - banglore
  • 8866065262
Turkey 42080 Equipment goods
photo not available

Saturday, July 04, 2009

We are speciallized in Automotive Spare Parts of world renown brands : Messy Fergusan,Fiat,New Holland and Belarus Tractors Spare parts. We are also specially working for Heavy Machinery spare parts like Catterpiller,Komatsu and Forklifts and their spare parts. We are also well aware...

Saaz İnternational consultant & Trading

  • saazceo
  • 42080 - Konya
  • +90332 2570400
  • +90533 4789777
photo not available

Monday, November 30, 2009

Quantity : 10000 m3 - Price : negotiated

We sell sawn timber, planed timber, unedged timber, profiled timber cant of spruce, fir, pine, ash, larch, oak, cedar, birch, linden, yew, elm, etc from Russia. Opportunities for any size, any quality. Work only with specification, we didn`t have a price, because the price depends...

Barwood

  • barwood
  • - Moscow
  • +79 1 00 03 33 03