AT902 Automated Filter Tester
AT902 AUTOMATED FILTER TESTER

Application:
AT902 Automated Filter Tester is a universal tester, development according to the standard of GB2626-2006-6.3, EN 149:2009, it mainly used for detecting the efficiency of the particulate respirator filtration and detecting the filtration efficiency and resistance of material.
The tester is divided into two categories, oil and salt fog. The oil spray tester is using DEHS as aerosol and the salt spray tester using NaCl, the solution spray after Ruskin nozzle and drying, then form in to aerosol. The system adopts precision instrument to control flow and concentration, and through integrate of system to communicate with computer, the system has good stability, and it is easy to operate.
By detecting the concentration of upstream and downstream, and then calculate the results through the formula. Airflow can be real-time monitored through electric proportional valve and flow meter, to ensure the accuracy of the test flow and the stability. The aerosol concentration can be monitored by electrical proportional valve and differential gauge, and provide stable test particles.
The filtering material tester is a fully automatic instrument which can control the following actions by a computer:
1) It can feedback control and read all of the working parameters automatically: including the volume, the resistance, and the efficiency.
2) Measuring the particle number and the resistance of sample in a test period.
3) The data stored in D: D: Eff(NaCl)-data, Or.D: Eff(Oil)-data
4) Showing operating parameters.
5) The system makes use of serial communication to initiating a transfer of the data files.
Standards:
|
EN143 |
GB2626-200 |
JMOL |
|
NIOSH 42 CFR 84 |
|
|
Note: For more standards, please contact us
Machine Construe:

Features:
1) Compliance with more regulations and well received by many customers
2) Simple, fast and automated operation
3) Highly consistent test results
4) Designed for manufacturing environments
5) Support Chinese and English, menu type operating mode and large LCD display, it's easy to switch
6) Computer control with special software
7) More test items
8) It equipped with two generators to test both salt and oil on one machine, you don't need to change any part of the machine or clear the part. It's easy to operate and high efficient.
Technical Specification:
|
Model |
AT902 |
|
|
Air volume |
(20〜100) L/min |
|
|
Efficiency |
10%-99.999% |
|
|
Aerosol |
Salt,DOP,DEHS, Paroline, Corn oil, optional |
|
|
Resistance |
0-2000Pa |
|
|
Aerosol density |
(50〜200) mg/m3(oil); (12〜20)mg/m3(salt) |
|
|
Detector |
Laser aerosol particle counter |
|
|
Detect temperature |
5~ 35℃ |
|
|
Related humidity |
0 ~ 90% RH |
|
|
OPC self-purification time |
≤10 mins |
|
|
OPC flow rate accuracy |
±5% |
|
|
OPC repeatability |
≤10% F.S |
|
|
OPC particle size distribution deviation |
± 30% |
|
|
OPC particle density deviation |
± 30% F.S |
|
|
Pressure detect |
Digital pressure sensor (pressure difference transmitter) |
|
|
Pressure detect range |
(0~0.88)MPa |
|
|
Pressure detect accuracy |
Grade 2.5 |
|
|
Efficiency testing range |
filter efficiency: 10~99.999% |
|
|
Operation display |
LCD display |
|
|
Power supply |
110~235V, 50Hz |
|
|
Dimension |
Main machine |
950mm × 600mm ×600mm |
|
Control cabinet |
750mm × 600mm ×600mm |
|
Standard Configuration:
|
No. |
Item |
Quantity |
|
1. |
Main machine |
1 set |
|
2. |
Laptop |
1 set |
|
3. |
Software |
1 copy |
|
4. |
Generator |
2 sets |
|
5. |
Air filter |
1 set |
|
6. |
Precision filter |
1 set |
|
7. |
Filter element |
1 set |
|
8. |
Respirator frock |
1 set |
|
9. |
Melt adhesive device |
1 set |
|
10. |
Melt adhesive |
20 pcs |
|
11. |
Calibration filter material |
50 pcs |
|
12. |
Air pipe joint |
1 box |
|
13. |
Φ8 & Φ15Air pipe |
2m |
|
14. |
Wash bottle |
1 pc |
|
15. |
Packing list |
1 pcs |
|
16. |
Quality certificate |
1 pcs |
|
17. |
User manual |
1 pcs |
Optional Configuration:
|
No. |
Item |
Quantity |
|
1 |
Customized filter holders |
|
|
2 |
Air compressor |
|
Contact : Eric Qin, +86 186 18655041869
Good deal: buying from seller
We invite you to read our terms of use. You can also visit our FAQ section and see our information section on the risks associated with counterfeiting.
|
This page is about importers and exporters of AT902 Automated Filter Tester Search in a category : Equipment goods Search in a category : automated, at902, tester, filter |
Tuesday, June 11, 2024
Quantity : 200 - Price : 15 500,00 €
AUTOMATIC SSD Proven effectiveness The AUTOMATIC SSD is the product par excellence. It has the ability to instantly clean all types of stains. Its effectiveness has been proven by every laboratory on the planet. Nominated since 2007 for product of the year, the UNIVERSAL SSD AUTOMATIC...
Laboratoire Topnet ssd automatique
- 75001 - Paris
- 07 51 05 59 76
- +33 7 51 05 59 76
Wednesday, February 13, 2019
Quantity : 1 - Price : 22 000,00 €
accuvix a30, establishes a new benchmark for state-of-the-art imaging, offering the world&aposs first 21.5-inch full hd led monitor, enriched 3d performance, increased detection rates, unparalleled automation, a sensitive interface and a forward-looking ergonomic design. features...
Tmcc
- 77056 - Houston
- 3254537597
Friday, July 08, 2022
Quantity : 100
Caractéristiques Type Éclairage de plafond intelligent Type d'ampoule LED Type de culot GU10 Couleur de la lumière Blanc Température de la couleur (min) 2000 K Température de la couleur (max) 6500 K Flux lumineux 350 lm Puissance de l'ampoule 5.7 W Puissance ampoule équivalente 32...
MaKant Europe GmbH & Co. KG
- 60386 - Frankfurt am Main
- +49 (69) 9 150 750 14