AT230 Thermal Cycling Tester
AT230 THERMAL CYCLING TESTER


Application:
AT230 Thermal Cycling Tester is designed according ISO and ASTM standard requirement; it's mainly used to check the leakage status of composite pipe & fittings when subjected to specify cycling times under specified internal pressure load. It's widely used in plastic pipe manufacture factory and some Labs.
Standards: ASTM F 1335-98; ISO 10508, 12293; GB/T 18742, 18992, 18993, 18998, 19472; CJ/T 138, 175
Note: For more standards, please contact us
Features:
1. Temperature control system
1) This control system equips separate temperature detector for cold water tank, hot water tank, header pipe input nozzle, header pipe output nozzle. Take 6 working as sample, there should be 16 pcs detectors
2) Main machine temperature control range: 10℃~98℃
3) Independent temperature detector to monitor sample room temperature
2. Pressure control system
1) Equipped with 16-byte A/D transverter to collect pressure
2) The pressure sensor range is 0 ~ 1.6MPa, display resolution reach to 0.001MPa

3. Water flow control system
1) Each work station equipped with a flow meter
2) The resolution of flow meter reach to 0.01m/s and 16 byte A/D transverter for water sampling

4. Communicate system
1) 16 pcs electromagnetic valve controller to control water input and output
2) 4 pcs electric parts to control the circulating pump
3) 4 pcs electric part to control heating and cooling system
4) One electric part to control water supply

5. General features
1) High temperature and high pressure only exist in the sample and short piping, that all the electric parts in circulation line work at normal pressure to attain a long service life.
2) Lockable transparent folding doors make samples installation more easily and allow easy access to all samples from three sides.


3) Testing control and monitoring of individually station takes over PLC and touch screen terminal.
4) Individual circulation time, flow rate and pressure can be selected.
5) It provides test constancy as regards to temperature, pressure and flow rate as well as lowering the energy consumption.
6) Several reliable safeguard, liquid level measuring devices, emergency stop switch and cord switch ensure the tester to be out of action in time if the test fails or piping system bursts. Doors shall be locked during testing period.
7) Pre-stress system was introduced to apply the initial tensile stress. This system is optional.
8) System enables pressure calibration and temperature calibration during testing, it means that system may continue running during calibration.
9) High quality grundfoss pumps are used to provide press in sample strings. Automatic water filling design ensures full tank capacity during the whole time.

Circuit diagram


Technical Specification:
|
Model |
AT230 |
|
Max. pressure |
1.6MPa |
|
Pressure control accuracy |
±0.05Mpa |
|
Pressure display resolution |
0.001Mpa |
|
Number of test stations |
6 (can customize) |
|
Alternation time between hot water and cold water |
≤1 min |
|
Cycle period |
300 ~ 1200s |
|
Number of cycles |
1 ~ 10,0000 adjustable |
|
Cold water temperature range |
15℃ ~ R.T adjustable |
|
Cold water temperature accuracy |
±2℃ |
|
Hot water temperature range |
R.T ~ 98℃ |
|
Hot water temperature accuracy |
±1℃ |
|
Temperature display resolution |
1℃ |
|
Temperature uniformity |
≤±1℃ |
|
Water flow accuracy |
0.01m/s |
|
Water flow display resolution |
0.001m/s |
|
Ambient temperature |
23℃±2℃ |
|
Max. total cross-section diameter of all connect test samples |
6200mm2 (2*Φ63) |
|
Power supply |
3phase, AC380V, 50Hz, 25KW |
|
Dimensions |
4600×2900×2000mm |
Standard Configuration:
|
No. |
Item |
Quantity |
|
1 |
Main machine |
1 set |
|
2 |
Sample chamber |
1 set |
|
3 |
Cold water tank |
1 set |
|
4 |
Chiller |
1 pcs |
|
5 |
Heat exchanger |
1 pcs |
|
6 |
Hot water tank |
1 set |
|
7 |
Heater for hot water tank |
1 pcs |
|
8 |
Control system |
1 pcs |
|
9 |
Pipe fixed system |
1 set |
|
10 |
Packing list |
1pc |
|
11 |
Quality certificate |
1pc |
|
12 |
User manual |
1pc |
Optional Configuration:
|
No. |
Item |
|
1 |
Flow measurement system |
|
2 |
Pre-stress system |
Contact : Eric Qin, +86 186 18655041869
Good deal: buying from seller
We invite you to read our terms of use. You can also visit our FAQ section and see our information section on the risks associated with counterfeiting.
|
This page is about importers and exporters of AT230 Thermal Cycling Tester Search in a category : Equipment goods Search in a category : cycling, thermal, at230, tester |
Tuesday, April 28, 2026
SIMCom presents an ultra compact and reliable wireless module SIM7250E which is based on Qualcomm MDM9225 multiple-mode LTE platform. SIM7250E is a complete multi-band LTE/HSPA+/HSPA/UMTS/EGDE/GPRS/GSM/GNSS PCIE module designed with very powerful processors integrating application core...
Connectec Electronics Co., Ltd.
- connectec123
- 235 - New Taipei City
- +886 2 8221 6389
Friday, July 08, 2022
Quantity : 100
Caractéristiques Type Ampoule intelligente Type d'ampoule LED Type de culot E27 Changement de couleur Oui Couleur de la lumière Multicolore Température de la couleur (min) 2000 K Température de la couleur (max) 4000 K Flux lumineux 806 lm Puissance de l'ampoule 9 W Puissance ampoule...
MaKant Europe GmbH & Co. KG
- 60386 - Frankfurt am Main
- +49 (69) 9 150 750 14
Saturday, June 18, 2022
Quantity : 100
Intel Core i9-9900K. Famille de processeur: Intel® Core™ i9 de 9e génération, Socket de processeur (réceptable de processeur): LGA 1151 (Emplacement H4), composant pour: PC. Canaux de mémoire: Dual-channel, Mémoire interne maximum prise en charge par le processeur: 128 Go, Types de...
MaKant Europe GmbH & Co. KG
- 60386 - Frankfurt am Main
- +49 (69) 9 150 750 14