Everything else / Bulk

2021 New design automatic circuit recloser/ Auto recloser

TD-CHZ16 protector integrates intelligent control functions such as over-current and short-circuit protection, under-voltage/over-voltage protection, leakage protection, remote communication management/fault memory, detection before closing, and automatic reclosing device. The new generation TD-CHZ16 protector has the characteristics of intelligence, safety, wide application range, stability and long service life.

Function of auto recloser

1. Short circuit protection:

When the current of the auto-reclosing leakage protector is greater than 3 times the rated current, the auto-reclosing leakage protector will be disconnected within 0.1 second to ensure the safety of the equipment.

2. Leakage Protection:

The leakage current of TD-CHZ16 factory setting is 30ma. When a 1530mA leakage occurs on the wire, the automatic circuit recloser will be disconnected within 0.1 second.

3. Overcurrent/load protection:

TD-CHZ16 type protector realizes the rated current 6A-10A-16A adjustable, and the maximum support is 16A. When the current is greater than 1.15 times the rated current, the auto-reclosing will monitor the duration and magnitude of this current; if the duration exceeds 3 seconds or is greater than 3 times the rated current, The automatic reclosing leakage protection switch is disconnected for protection

4. Overvoltage protection:

When the supply voltage is higher than 275V±5V, the auto-reclosing will be disconnected. After the voltage drops back to normal, the auto-reclosing will automatically close and energize.

5. Undervoltage protection:

When the power supply voltage is lower than 150V±5V, the automatic reclosing will be disconnected. After the voltage rises to normal, the automatic reclosing will automatically close, The power-on operation status is normal.

6. Detection before closing:

The automatic reclosing detects the line voltage before closing. When the power supply voltage is abnormal under-voltage or over-voltage, it will block the closing

and Alarm; if the fault is not eliminated, the switch cannot be closed and energized. When the fault is removed, the switch will automatically close and energize.

7. Auto reclosing characteristics: (adjustable)

When there is an instantaneous leakage or an instantaneous impact on the line, such as lightning, socket flashover, etc., and there may be danger, the automatic reclosing leakage protector will be disconnected immediately;

After the fault, if the line is safe, the auto-reclosing will automatically reclose and energize. The number of closing times is unlimited

8. Manual on-off performance

8.1. When the test button is pressed manually for leakage, the neutral wire and the live wire are disconnected correspondingly, and there is no output. After 60 seconds, it will automatically close, and the auto-reclosing protector will work normally.

8.2 After the power switch is manually turned off, the two relays are disconnected at the same time, and there is no output. The on-off action time is less than 0.1 second. Restart the switching power supply and output both at the same time.

For more information about auto recloser working principle and signal surge protector, please feel free to contact us!

If you are looking for a reliable surge protector supplier, don't hesitate to contact us!

Location : Build D, Huafeng Hi-Tech Industrial park, Jinlan Road, Large Industrial Park, Pingshan district, Shenzhen, 518118 Shenzhen,
Contact : win Tech, 0755 86215101

Good deal: buying from seller

Visit our guide for a secure transaction! Under no circumstances Algomtl can be held responsible for the content of the ads published. Only the sellers and buyers responsability is involved in case of dispute.
We invite you to read our terms of use. You can also visit our FAQ section and see our information section on the risks associated with counterfeiting.
This page is about importers and exporters of
2021 New design automatic circuit recloser/ Auto recloser

Search in a category : Everything else / Bulk
Search in a category :
design, automatic, auto, circuit, recloser
Hong Kong 523929 Health / Hygiene
Rooman Home Air Purifier AC300

Tuesday, August 18, 2015

Quantity : 200 at lea - Price : To be discussed

Key Specification: - Color: Various color can be chosed - Input Voltage: 120~240V - Rated Power: 50-60HZ - Power (W): 36~55W - Noise Level: 25~55dB - Display Mode:LED - Control Mode: Touch screen - CADR: 320m³/H - Purifying Rate: 99.7% - Length Of Power Cord: 2...

Rooman Electrical Appliances Co., Ltd.

  • Rooman1
  • 523929 - Dongguan
  • +13 6 62 88 32 70
Switzerland 3600 Decoration
Kleiderständer Garderobenständer Edelstahl

Thursday, September 18, 2014

Details: - Fabrikneu und feine Verarbeitung - Hochwertige Edelstahl Stangen - Kann durch seine leicht laufende 360°drehbare Rollen schnell und einfach an einen passenden Ort platziert werden - Einfach zu montagen - Ausziehbare Kleiderstange und verstellbare Höhe - Kompakte Rohrausführung...

365buy

  • 3600 - Thun
  • 07 62 07 63 81
Taiwan 335 Equipment goods
Full control PC under any OS, in BIOS mode, during boot, at Blue Screens

Wednesday, May 20, 2015

AI101P Single Port KVM over IP The KVM over IP technology (IP-KVM) combines digital remote KVM access via IP networks with comprehensive and integrated system management. The IP-KVM defines a new class of remote KVM access devices that can save your money, time, space, and equipment...

ACAFA Information Co.

  • epanio
  • 335 - Dasi Township
  • +88 6 33 07 13 00