Raw materials
FDA Medical Grade Soft RTV2 Moldmaking Platinum Cured Liquid Silicone Rubber LSR Raw Ma... |
| Model Code | GTSIL-P10 | GTSIL-P15 | GTSIL-P20 | GTSIL-P25 | GTSIL-P30 | GTSIL-P35 | GTSIL-P40 |
| Hardness - Shore A | 8-10 | 14-16 | 19-21 | 24-26 | 28-30 | 34-36 | 38-42 |
| Viscosity - Cps | 3000-5000 | 4000-6000 | 4000-7000 | 5000-8000 | 6000-9000 | 6000-10000 | 4000-6000 |
| Mixing Ratio - % | 1: 1 | 1: 1 | 1: 1 | 1: 1 | 1: 1 | 1: 1 | 1: 1 |
| Tear Strength - KN/m2 | 14-17 | 16-18 | 18-22 | 22-26 | 20-23 | 16-19 | 12-16 |
| Tensile Strength - Mpa | 3.5-5.5 | 4-6 | 4-6 | 4-6 | 4-6 | 4-6 | 3.5-5.5 |
| Shrinkage - % | 0.10% | 0.10% | 0.10% | 0.10% | 0.10% | 0.10% | 0.10% |
| Elongation - % | 500-600% | 500-600% | 500-600% | 400-500% | 400-500% | 350-500% | 300-450% |
How to use
1.Substrate Preparation
The surface of the original should be clean and free of loose material. If necessary, and in particular with porous substrates, use a suitable release agent such as petroleum jelly or soap solution.
2. Mixing
Thoroughly stir Part A (silicone base) before use as filler separation may occur upon prolonged storage.
Weigh 100 grams Part A (silicone base) and 3 grams Part B (curing agent) in a clean container. Mix together until the curing agent is completely dispersed in the base. Hand or mechanical mixing can be used, but do not mix for an extended period of time or allow the temperature to exceed 35°C (95°F). Mix suitably small quantities to ensure thorough mixing of the par A (silicone base) and part B (curing agent).
It is strongly recommended that entrapped air be removed in a vacuum chamber, allowing the mix to completely expand and then collapse. After a further 1-2 minutes under vacuum, the mix should be inspected and can be used if free of air bubbles. A volume increase of 3-5 times will occur on vacuum de-airing the mixture, so a suitably large container should be chosen.
Caution: prolonged vacuum will remove volatile components from the mix and may result in poor thick section cure and non-typical properties.
Note: If no vacuum de-airing equipment is available, air entrapment can be minimized by mixing a small quantity of par A (silicone base) and part B (curing agent), then using a brush, painting the original with a 1-2mm layer. Leave at room temperature until the surface is bubble free and the layer has begun to cure. Mix a further quantity of base and curing agent and proceed as follows to produce a final mold.
3. Pouring the Mixture and Curing
Pour the mixed Par A (silicone base) and Part B (curing agent) as soon as possible onto the original, avoiding air entrapment. The catalyzed material will cure to a flexible rubber within 24 hours at room temperature (22°C-24°C/ 71.6°F - 75.2°F) and the mold can then be separated from the original. If the working temperature is significantly lower, the cure time will be longer. If the room temperature or humidity is very high, the working time of the catalyzed mixture will be reduced. The final mechanical properties of the mold will be reached within 7 days.
Good deal: buying from seller
|
This page is about importers and exporters of FDA Medical Grade Soft RTV2 Moldmaking Platinum Cured Liquid Silicone Rubber LSR Raw Ma... Search in a category : Raw materials Search in a category : moldmaking, platinum, cured, rtv2, medical, soft, grade |
Wednesday, December 03, 2014
I am Grace Gao from SÄVE/RABECO and I have been assigned to distribute paper to you. Firstly, I would like to take a minute of your time to briefly introduce our Company and our activities. SÄVE PULP AND PAPER. belongs to a privately owned business group founded...
Wednesday, September 14, 2016
Quantity : 5000 - Price : 50,00 €
Gland Packing Globe Valves ( Straight- Through Type) DIN Standard Gland Packing Globe Valve DIN Globe valve DIN Stop valve DIN Absperrventil Durchgangsform DIN Válvulas de globo DIN ventil uzavírací s klasickou ucpávkou přímý DIN Standard seteventiler med pakkboks (rett løp...)
Tuesday, May 26, 2026
Quantity : 200000
- - Location : 360 avenue des bigos 34740 vendargues, 34740 vendargues, Contact : stephane gelly, 06 51 87 22 64