Dryzone dry storage cabinet has developed different series of drying cabinets for sale to meet the requirements of different product stores, miniature devices, pharmaceutical substances, batteries, crystals, optical lenses, scientific instruments, and biotic specimens.
Different humidity ranges of desiccant dry storage cabinets for different levels of components: 1-50%RH(adjustable)series,15-50%RH(adjustable)series,<5%RH(Auto)se ries,<1%RH(Auto)series,40-60℃</span>(adjustable)<1%RH series</span>;
N2 cabinet, Dry air cabinet, Desiccant dry cabinet, or N2 cabinet is more suitable for those who have high requirements for humidity recovery;
ESD, Stainless steel humidity control dry cabinet is suitable for cleanroom use;
Slide drawer for Reel/PCB/IC/BGA/SMD components store;
If the above features can not meet your requirements, you can also contact us for custom dry storage cabinet solutions.
DRYING CABINET FOR SALE
Industrial Drying Cabinet
CQS-1200-6 Nitrogen Cabinet
Humidity Range: 1~50%RH, adjustable
Outside Dimension: W1200*D672*H1820MM
Internal Dimension: W1198*D644*H1618MM
Nitrogen Filling Module: QDN*1
Loading capacity of shelf: 80 kgs/per shelf
Capacity: 1250L
Shelves: 5 pcs, adjustable
Color: Silver
Structure: SUS 304
Display Precision: ±3%RH;±1°C
Resolution: 0.1%RH; 0.1°C
Power Consumption: Ave. 20W/h; Max. 50W
Industrial Drying Cabinet
<1 Rh Ultra Low Dry Cabinet CF1 Series</span>
<5% Rh Dry Cabinet C2E Series</span>
1-50% Rh Drying Cabinet C1U/C1B Series
15-50% Rh Dry Cabinet C15U/C15B Series
More Dry Cabinets
Nitrogen Cabinet
CQS-1200-6 Nitrogen Dry Nitrogen Box
Humidity Range: 1~50%RH, adjustable
Outside Dimension: W1200*D672*H1820MM
Internal Dimension: W1198*D644*H1618MM
Nitrogen Filling Module: QDN*1
Capacity: 1250L
Shelves: 5 pcs, adjustable
Loading Capacity of Shelf: 80 kgs/per shelf
Color: Silver
Structure: SUS 304
Display Precision: ±3%RH;±1°C
Resolution: 0.1%RH; 0.1°C
Power Consumption: Ave. 20W/h; Max. 50W
Nitrogen Cabinet
Dryzone Products Nitrogen Desiccator Cabinet
Baking Dry Cabinet
E60C-600 Baking Dry Cabinet
Temperature Range: 40~60℃ adjustable, <1%RH</span>
Outside Dimension: W600*D780*H1966MM
Internal Dimension: W540*D500*H1460MM
Capacity: 426L
Shelves: 5 pcs SUS304, adjustable
Loading Capacity of Shelf: 80 kgs/per shelf
Color: Black
Structure: 1mm carbon steel with ESD paint, double layer filled with insulation cotton
Display Precision: ±3%RH;±1°C
Resolution: 0.1%RH; 0.1°C
Power Consumption: Ave.350W/h; Max. 1650W
Baking Dry Cabinet
E60C Series Baking Dry Cabinet
Digital Hygrometer
Operation Range: 0~50℃, 0~90%RH
Precision: ±1℃, 2.0%RH(at 50%RH/25℃)
Resolution: 0.1℃, 0.1%RH
Dimension: W310xD70xH320mm
Visibility Distance: 30m
Weight: 3kgs
Power: 110V/230V (select voltage in advance)
Power Consumption: Ave.12W/h
Calibration Reminding: Yes
Alarm Setting (%RH): Yes
Alarm Setting (℃): Yes
Alarm Buzzer: Yes
Alarm Flash: Yes
Data Logger: Yes
RS232 Port: Yes
Calibration Report: Yes
Digital Hygrometer
Cp03u Accurate Hygrometer
Ht-5d Digital Hygrometer
Commercial Drying Cabinet
HDL-188 Commercial Drying Cabinet
Humidity Range: 25~55%RH, adjustable
Outside Dimension: W400*D895*H408MM
Capacity: 124L
Shelves: 3 pcs
Commercial Drying Cabinet
Guitar Dry Cabinet
Camera Dehumidifying Dry Cabinet
Dry Cabinet Accessories
Alarm tower is an optional accessories which could install in our dry cabinet or hygrometer for easy visual and sound alarm alert.
HUMIDITY CONTROLLED STORAGE CABINET FEATURES
Short Recovery time
Coming down to <1%RH within 30 mins after the door open for 30 seconds and closed. </span>
Energy Saving
40%-60% nitrogen could be saved by using our QDN.
Central Monitor
Sensor look software and humidity manager could be equipped within our dry storage cabinets if you are in need.
DRYZONE HUMIDITY CONTROL SOLUTIONS
Electronic Components
At Dryzone, we understand that your electronic components are valuable assets, and we are dedicated to providing the best possible storage solutions for your needs. Invest in our dry storage cabinets ...
Semiconductor
Dryzone nitrogen cabinet are widely used in Semiconductor field, especially the CQS( stainless steel 304) series, as wafer has strict low humidity demand and high demand on recovery time, Dryzone nitrogen cabinet could satisfy clients need.
SMT
Dryzone industrial cabinet and hygrometer has put into SMT production line use and help clients reduce the product breakage rate and save lots of money for clients.
Phoelectric Optical Communication
Dryzone dry cabinet with QDN (nitrogen saving module) with its quick recovery time and flexiable humidity control are widely used in Phoelectric optical communication field.
Automotive Electronics
C2B series Dryzone dry cabinets are wildly used in Automotive electronics. As the Automotive electronics components need to store in a low humidity environment normally <5% RH to protect it.</span>
Biomedicine
Biological reagent and medicine needs to be well protected from moisture damage or it will affect its test result and effect, Dryzone C1 and C15 series dry cabinet is well applicated in this field.
Lab and Others
School labs always have some lab instrument or products which need to store in dry cabinet, Dryzone dry cabinet, dryzone glove box has served in lots of high unviersity labs.
Customers
We could make customized dry cabinet if you could not find the suitable one in our standard dry cabinet.
CABINET DRYER WORKING PRINCIPLE
Cabinet Dryer Working Principle
Dessicant dry cabinet Dehumidification Theory
The humidity storage cabinet will absorb moisture through the imported material (molecular sieve) physically, after saturation, heating, through the memory alloy opening and closing, the moisture is exhausted in the form of water vapour. Thus repeatedly, until it reaches IC program set humidity value.
Nitrogen or Dry air Dehumidification Theory
To fill N2 or dry air into the humidity-controlled dry storage cabinet, squeeze the HO2 out of the dry cabinet, then make the humidity go down. By using our QDN(Nitrogen Saving Module), could save 40-60%RH N2 or dry air.
HOW TO USE DRY CABINET?
Step 1
Make even the dry storage cabinet. If the floor is not even, the door will be stretched to an unparallel situation. Adjust the knob to even the humidity storage cabinet.
Step 2
Connect the modules according to the wiring Diagram. Please ensure the Voltage Requirement of our drying cabinet for sale matches your electric source before connecting.
Step 3
For the first time operation. Please maintain an empty dry storage cabinet and switch it on for 24 hours before storing any items. Then, you can set the humidity according to the manual.
Special Notes
Moveable column: The moveable column can be taken out for installing the shelves.
Now the dry cabinet price is reasonable, if you have needs to buy dry cabinet, please contact us.
As one of dry cabinet suppliers, we can offer sorts of related products for sale, if you have needs, please contact us.
Location : No 2898,Beimen Rd,Kunshan, Jiangsu,China, 215300 jiangsu,
Contact : Dryzone Dryzone, 86 21 61275768