Digital Gas Steam Liquid Vortex Flow Meter |
| Nominal pass(mm) | 15,20,25,40,50,65,80,100,125,150,200,250,300 |
| Instrument material | 1Cr18Ni9Ti |
| Nominal pressure (Mpa) | PN1.6Mpa;PN2.5Mpa;PN4.0Mp |
| Measured medium temperature(ºC) | -40~+250ºC;-40~+350ºC |
| Environmental conditions | Temperature -10 ~ +55 ºC, relative humidity of 5% to 90%, atmospheric pressure 86 ~ 106Kpa |
| Accuracy | Liquid: ± 0.5 for indication; gas or steam: ± 1.0,± 1.5for indication |
| Range ratio | 1: 10;1: 15 |
| Resistance loss factor | Cd<2.6</td> |
| output signal | Optional 4-20mA or pulse |
| Power supply | Sensors: + 12VDC, + 24VDC (optional) |
| Transmitter: + 24VDC | |
| Live display type: instrument comes with 3.2V lithium battery | |
| Signal transmission line | STVPV3 × 0.3 (three-wire), 2 × 0.3 (two-wire) |
| Installation method | Flange clamp or integral flange connection |
| Transmission distance | ≤500m |
| Signal line interface | Internal thread M20 × 1.5 |
| Explosion protection rating | ExdIIBT6 |
| Protection class | IP65 |
| Allow vibration acceleration | 1.0g |
4.The measuring range of the digital vortex flow meter:
| Caliber (mm) | Liquid measurement range (m3 / h) | Gas measurement range (m3 / h) |
| DN15 | 1.2-6.2 | 5-25 |
| DN20 | 1.5-10 | 8-50 |
| DN25 | 1.6-16 | 10-70 |
| DN32 | 1.9-19 | 15-150 |
| DN40 | 2.5-26 | 22-220 |
| DN50 | 3.5-38 | 36-320 |
| DN65 | 6.2-65 | 50-480 |
| DN80 | 10-100 | 70-640 |
| DN100 | 15-150 | 130-1100 |
| DN125 | 25-250 | 200-1700 |
| DN150 | 36-380 | 280-2240 |
| DN200 | 62-650 | 580-4960 |
| DN250 | 140-1400 | 970-8000 |
| DN300 | 200-2000 | 1380-11000 |
5.The application of the digital vortex flow meter:
The digital vortex flow meter is a volumetric flowmeter that can measure the volumetric flow of gas, steam or liquid, volumetric flow or mass flow.And can be used as a flow transmitter in the automated control system.
Good deal: buying from seller
|
This page is about importers and exporters of Digital Gas Steam Liquid Vortex Flow Meter Search in a category : Equipment goods Search in a category : digital, liquid, flow, vortex, meter, steam |
Tuesday, March 03, 2026
Waterproof Terry Cloth Mattress Protectors (PU Laminated Terry Mattress Covers) Waterproof and Breathable Terry cloth with PU membrane 80%cotton+20%polyester 170-180 gsm (can be arranged regarding customer needs) Protects mattress against all kinds of liquid spillage Durable stretched...
Tuesday, March 03, 2026
Flannel/Molton Waterproof Mattress Protectors (Cotton Mattress Covers/Bed Pads) Waterproof and Breathable Flannel fabric with PU membrane 100% cotton woven fabric 160-180 gsm (can be arranged regarding customer needs) Protects mattress against all kinds of liquid spillage...
Friday, May 16, 2014
Quantity : 50000pcs - Price : $1-25/pc
Prototype Description SLA and SLS Why Use Stereolithography? Stereolithography is very similar to the SLS(Selective Laser Sintering) prototyping process.It's best to use SLA,when surface finish and overall appearance straight from the machine is the most important factor in the prototype...