Equipment goods
Automatic Safety Test System
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Withstand Voltage Test (AC/DC) | Insulation Resistance Test (IR) | ||||
| Voltage Range | Accuracy | Current Range | IR Range | Accuracy | Voltage Range |
| 100~4000V | ± (5%+3V) | AC: 0.10~20.00mA DC: 0.10~12.00mA |
1.00~2000MΩ | 5% + 0.5MΩ | DC100~1000V |
| Leakage Current Test (LLC) | Grounding Resistance Test (GR) | ||||
| LLC Range | Accuracy | Voltage Range | GR Range | Accuracy | Output Current |
| 0.10~20mA | ± (0.3%+5uA) | AC10.0~300.0V | 0~600mΩ | ± (5%+2mΩ) | AC1.00~30.00A |
| Power Test | |||||
| Voltage | Current | Power | PF | Accuracy | Test Time |
| 10~300V | 0.010~20.00A | 1.0~6000.0W | 0.2~1.0 | Class 0.5 | 0~999.9s |
What's the test method of Automatic Electrical Safety System?
Pls. note that the DC high voltage output is a negative voltage, and the ground is a positive. When testing capacitance, there is a charging process when voltage is applied to both ends of the capacitor. At this time, there is a charging current in the test circuit. When the current is greater than the set leakage current value, the withstand voltage tester will alarm to interrupt the test , it cannot be proceed. Therefore, when the safety tester is testing, the voltage should be increased slowly, and the charging current should be less than the set leakage current value until the test voltage is specified, and the test should be performed. It is not possible to use a fixed voltage, reset-start method for testing. In the AC circuit, it is equivalent to the resistance in the DC circuit. […more…]
Good deal: buying from seller
|
This page is about importers and exporters of Automatic Safety Test System Search in a category : Equipment goods Search in a category : system, test, safety, automatic |
Friday, September 27, 2013
Quantity : 1 - Price : 1,00 €
As owner, we have for sale the following nice machine : Sale Heidelberg SM 74-2, Year 2000 52x74 - 2 Colors - ca. 51 impressions, CP Tronic, Autoplate, Preset, All Auto. Wash, Alcolor Dampening with Baldwin refrigeration system, Electronic Double Sheet & Sidelay Detector, Segmanted...
Wednesday, December 10, 2014
H7 Xenon Slim Kit BALLAST Brenner 6000K Brenner + Steuergerät Für Vorne 2 Stk. Licht Autobrenner Beschreibung: Diese Glühlampen sind aus hoher Qualität. Die sind mit Xenongas gefüllt. Durch einfache Montage können sie sofort funktionieren. Das Licht ist extra hell und stark, damit...
Friday, May 23, 2014
Quantity : 2 - Price : 850,00 €
Used refrigerated buffet state I have two rooms available (identical) equipped roulette static cooling system for more information: gas CE compliant VAT price, except areas Europe (EU VAT) for more information: M.C.FRANCE SAS Street expectancy 75 59100 Roubaix TEL: 09...