Search / buy
Fire Resistant Single Core 300-500V
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Nominal Cross Section Area |
No./Nominal Diameter of Strands |
Nominal Insulation Thickness |
Nominal Sheath Thickness |
Without Earth Conductor |
|
|
mm² |
No./mm |
mm |
mm |
Nominal Overall Diameter |
Approx. Weight kg/km |
|
mm |
|||||
|
1.5 |
7/0.53 |
0.5 |
0.5 |
4.4 |
29 |
|
2.5 |
7/0.67 |
0.5 |
0.5 |
4.9 |
40 |
|
4 |
7/0.85 |
0.5 |
0.5 |
5.5 |
55 |
Description of Fire Resistant Single Core 300-500V
Rated voltage: 300/500V
Basic standard: BS 7211
Conductor: bare annealed copper wire, stranded wire to IEC(EN) 60228 class 2
Fire lyer: Mica glass tape
Insulation: PVC (XLPE)
Sheath: LSZH compound to BS 7655-6.1
Operating temperature range (fixed state): -30°C – +90°C
Operating temperature range (mobile state): -20°C – +50°C
Min bending radius: 6 time of Overall Diameter
Insulation resistance: 20 MΩ x km (at 20°C)
Short circuit temperature: 250°C
|
Circuit Integrity |
IEC 60331-21; BS 6387 CWZ; DIN VDE 0472-814(FE180); |
|
|
CEI 20-36/2-1; SS229-1; NBN C 30-004 (cat. F3); |
|
|
NF C32-070-2.3(CR1) |
|
Flame Retardance (Single Vertical Wire Test) |
EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; |
|
|
VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); |
|
|
CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* |
|
Reduced Fire Propagation (Vertically-mounted bundled wires |
EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30- |
|
|
004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 |
|
Halogen Free |
IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; |
|
|
CEI 20-37/2-1 ; BS 6425-1* |
|
No Corrosive Gas Emission |
IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; |
|
|
CEI 20-37/2-2 ; BS 6425-2* |
|
Minimum Smoke Emission |
IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; |
|
|
CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* |
|
No Toxic gases |
NES 02-713; NF C 20-454 |
Application Of Fire Resistant Single Core 300-500V
The cables are designed for facilities where keeping and maintaining integrity of the electrical circuit is critical in power supply system.
The cables are widely used in underground tunnels, emergency lightings, fire alarm systems, control and power circuits, power stations, lifts, escalators, and high-rise buildings.
As a reliable electric cable factory, we can offer sorts of xlpe insulated cable for sale, if you are interested, please contact us.
Good deal: buying from seller
|
This page is about importers and exporters of Fire Resistant Single Core 300-500V Search in a category : Search / buy Search in a category : resistant, 500v, single, core, fire |
Tuesday, January 06, 2026
•Our organic olive groves and farmlands certify the environmentally friendly growing methods that fully respect natural cycle of crop and biodiversity. •The oil is made in our own milling/bottling installations, according to the local tradition handed down from our ancestors, combined...
Tuesday, September 08, 2015
Module parameters HD-720P-38*38mm 1.0megapixel low-illumination HD web camera Network Camera - Sensor type 1/4 inch、1.0megapixel , CMOS low-illumination width dynamic sensor - Minimum illumination Color: 1 Lux/F1.2, black and white: 0.02Lux/F1.2 - Electronic shutter 1/5 second ~ 1/50...
Tuesday, July 22, 2014
Pearl white LED rope light emits a vanilla white color which is similar to neon white. It is manufactured by InGaN technology which is trustable and sophisticated, producing the exact customized white color we expect. It is made of vanilla PVC tubing, filled with bright white LED's...