What Is a Dental Handpiece
Dental handpiece burs is a tool commonly used in dental treatment for oral patients. Dental handpiece cleaning machine can be divided into high speed handpiece and low speed handpiece.The speed of high-speed handpiece reaches 350-420,000 revolutions per minute, which is mainly used for treatment and repair (such as drilling and cutting).Low speed handpiece are divided into straight handpiece and bending handpiece. The straight handpiece is used for polishing and treatment outside the mouth, while the bending handpiece is used for treatment inside the mouth.It is well made and complex in structure
TX-164A High Speed Handpiece
TX-164A dental handpiece China first E-generator integreatevd led high speed handpiece.
BD-4 Eversun Dental Handpiece
BD-4 dental handpiece is a kind of dental handpiece with strong use force, high working efficiency and faster molar teeth.
Dental Fiber & E-generator Handpiece
Dental fiber Fiber & E-generator Handpiece adopts Germany imported bearing shaft, good quality and long life, patent dust prevention mechanism movement, effectively prevent impurities, longer life.
XM-H0704 LED Light Dental Handpiece
XM-H07045 LED lights chrome-plating body, prevent scratches, durable 5 spray, best cooling effect Hygiene head system prevent cross infection 8 bead ceramic ball bearing from Germany Myonic Longer service life.
KV-636 Dental High Speed Handpiece With Led Light
KV-636 dental LED lights chrome-plating body, prevent scratches, durable 3 spray,best cooling effect Hygiene head system prevent cross infection 8 bead ceramic ball bearing from Germany Myonic Longer service life.
ST3T High Speed Handpiece With Led Light
ST3T high speed handpiece with LED light chrome-plating body, prevent scratches, durable warranty 6 months 3 spray, best cooling effect Hygiene head system prevent cross infection 8 bead ceramic ball bearing from Germany Myonic Longer service life.
How the Dental Handpiece Works
Its working principle is driven by compressed air to drive the wind wheel to rotate at a high speed, thereby driving the dental bur to complete operations such as drilling and grinding the tooth.
Types of Handpieces in Dentistry
1. According to the connection mode with the connecting pipe, it can be divided into the one with quick coupling and the one without quick coupling
2. According to the connection type of the connecting pipe, it can be divided into two holes (driving gas, water); three holes (driving gas, water, atomizing gas); four holes (atomizing gas, return gas) and six fiber holes (driving gas) , Water atomization gas, return gas and two electrode columns) mobile phone.
3. According to the exhaust mode of the mobile phone, it can be divided into internal exhaust (four holes and six holes) and external exhaust (two holes) mobile phones.
4. According to the diameter of the mobile phone head, it can be divided into large (head diameter φ12.2); medium (head diameter φ11.2); small (head diameter φ10.2). Due to the different size of the head, the power of the phone is also different, and the use is also slightly different.
5. According to the installation and removal methods of mobile phone burs, it can be divided into two types: gland type and wrench type.
Dental Handpiece Maintenance
Pneumatic oil spray tank is the most ideal lubrication tool. It can not only lubricate dental handpieces, but also achieve the effect of cleaning bearings and wind wheels.
1. Remove the bur before using the oil spray can (the screw-type dental handpiece can be turned 1/4 turn), wrap the machine head with paper, and insert the nozzle of the oil can into the air inlet of the dental handpiece to ensure that there is enough Air pressure.
2. The air pressure spray tank must be used vertically, each spraying for 2-3 seconds.
3. The nozzle of the 2-hole dental handpiece is aimed at the large hole; the nozzle of the 4-hole dental handpiece is aimed at the second largest hole.
4. For the dripping method, drip 4 drops of oil against the big hole, and then use an air gun to blow intermittently into the oiling hole for 30 seconds.
5. It is strictly forbidden to use industrial lubricants for lubrication to prevent patients from being poisoned.
6. Dental handpieces that have not been used for a long time should be fully oiled, sealed and stored.
Use of Dental Handpiece
1. When using the dental handpiece, it must be careful, meticulous, and slight. It is strictly forbidden to operate it brutally, and do not drop the phone to the ground;
2. Regardless of the angle, you should follow the up and down lifting method to operate, do light touch, jog, and do not force sideways.
3. Use improved pen-holding style to hold the phone, find a stable fulcrum, and operate intermittently.
4. According to the different tooth positions and different shapes of the prepared holes, replace the mobile phone and the needle in time to minimize the wear of the mobile phone bearings.
5. To use sharp burs, blunt burs are not only time-consuming and laborious, but also cause damage to the mobile phone and increase the suffering of patients.
6. When using the dental handpiece, always check whether the bur is loose, so as not to cause flying needles. 7. Choose different mobile phones according to different clinical situations (for example, use a mini-type mobile phone that does not affect the line of sight when the posterior teeth is opened; use a strong and high-torque dental mobile phone in tooth preparation)
8. The one-time workload is too large. Two dental handpieces should be used in turn. One is to prevent the dental handpiece from being damaged by excessive load, and the other is to save the time of replacing the dental handpiece.
9. The movement of the dental handpiece has severe radial swing. It is strictly forbidden to use it when it moves longitudinally, and it is strictly prohibited to use the dental handpiece when there is no water or water shortage.
10. Air pressure and water pressure will change with how much the treatment table is used. Therefore, the air pressure and water pressure should be checked frequently during clinical operation to ensure the normal use of the dental handpiece.
dental Handpiece Sterilization
Usually, sterilization is defined to destruct all forms of life consisting of sporing forms of microorganisms, while disinfection serves as a way to destroy pathogenic non-sporing microorganisms. All heat-stable dental lab handpieces should be sterilized after the use of each patient by steam under pressure (autoclaving), dry heat, or chemical vapor. And remember to clean the electric dental handpiece before sterilization or high-level disinfection in order that any debris can be removed.
Dental handpiece repair parts
Generally speaking, the surgical handpiece dental can function effectively for one year before refurbishing or replacement. Therefore, it is of great significance for clinicians to confirm which portable dental handpiece can better withstand repeated heat sterilization without an operative performance loss. Remember if it works, don't repair the handpiece in dentistry. That is to say, if your handpiece can work correctly, then you don't need to repair or change it. However, if problems remain, you may closely review your repair procedures. If you are using maintenance-free bearings in your handpiece, the spindle still requires to be cleaned and lubricated once a week.
Dental Handpiece Function
The handpiece in dentistry serves as a hand-held, a mechanical instrument that is used for performimg a variety of common dental procedures, such as removing decay, polishing fillings, performing cosmetic dentistry, altering prostheses and so on. A high-speed portable dental handpiece is a precision medical device to remove tooth tissue efficiently. The surgical handpiece dental enables to restore cavities or crowns and remove a tooth during surgery.
If you want to know more types of dental equipment, please contact us.
We have different types of portable dental unit for sale, if you have needs, please leave us a message.
Location : Room 211, Feifang Base, 103 Jianshe Road, High-tech Zone, Tangshan City, Hebei Province, 063000 High-tech Zone,
Contact : roupen umg, 0315 6314398